Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Plan Number - S06-144
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
01/11/2007 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
01/18/2007 | JOSE ORTIZ | COT NON-DSD | TRAFFIC | Approved | |
01/24/2007 | AVERA1 | ENV SVCS | REVIEW | Approved | * Complied with initial review requests. Lot 19 thru 21, trash collection detail on page (3) identifies refuse point of collection. |
01/25/2007 | FRODRIG2 | PIMA COUNTY | WASTEWATER | Approved | January 25, 2007 TO: Chuck Martin, P.E.. Rick Engineering, Inc. THRU: Patricia Gehlen, CDRC Manager City of Tucson Development Services Department FROM: Chandubhai C. Patel, P.E., Civil Engineering Manager Pima County Development Services Department Development Review Division (Wastewater) SUBJECT: Oasis - Golf Links Lots 1-44 & Common Area "A-1" & "B-1" thru "B-3" & "C-1" thru "C-3" & "D-1" thru "D-4", Tentative Plat – 2nd Submittal, S06-144 The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. The Pima County Department of Environmental Quality and the Wastewater Management Department hereby approve the above referenced submittal of the Tentative Plat as received by us on January 10, 2007. Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality Department. Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating, or engaging in any activity which may cause or contribute to air pollution. If you have any questions regarding the above comments, please do not hesitate to contact me. Sincerely, Chandubhai C. Patel, P.E. Telephone: (520) 740-6563 Copy: Project File |
02/05/2007 | JOE LINVILLE | LANDSCAPE | REVIEW | Approved | |
02/05/2007 | ROGER HOWLETT | COT NON-DSD | COMMUNITY PLANNING | Approved | DEPARTMENT OF URBAN PLANNING & DESIGN Regarding SUBJECT: Community Design Review Committee Application CASE NUMBER: CASE NAME: DATE SENT S06-144 Oasis Golf Links 02/05/07 (XXXX) Tentative Plat () Development Plan (XXXX) Landscape Plan () Revised Plan/Plat () Board of Adjustment () Other CROSS REFERENCE: NEIGHBORHOOD PLAN: South Pantano GATEWAY/SCENIC ROUTE: COMMENTS DUE BY: 02/09/07 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: () No Annexation or Rezoning Conditions, Not an RCP - No Comment () Proposal Complies with Annexation or Rezoning Conditions () RCP Proposal Complies With Plan Policies () See Additional Comments Attached (XXXX) No Additional Comments - Complies With Planning Comments Submitted on: 07/21/06 () Resubmittal Required: () Tentative Plat () Development Plan () Landscape Plan () Other – Color Elevations, Photos 07VIEWER: drcorral 791-4505 DATE: 01/26/07 |
02/13/2007 | FRODRIG2 | COT NON-DSD | REAL ESTATE | Denied | S06-144 Oasis Golf Links: Resubmittal - CDRC - Tentative Plat Review - Request a "1' No Vehicle Access Easement" be placed along the S. boundary of C.A. "B-1" in addition to the proposed screen wall. |
02/22/2007 | TERRY STEVENS | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Terry Stevens Lead Planner PROJECT: S06-144 Oasis Golf Links Tentative Plat TRANSMITTAL: 02/22/07 DUE DATE: 02/09/07 COMMENTS: 1. DS 2-03.2.4.A Provide the distance and bearings for the subdivision boundary line along the southern boundary. See engineering comments. 2. DS 2-03.2.4.G Provide in note #26 that the DSMR was approved without conditions. 3. DS 2-10.3.2. E. Zoning acknowledges your response to the following comment. The comment will remain as a reminder to the reviewer. Three (3) copies of Covenants, Conditions, and Restrictions (CC&Rs) are required if there is to be an association of home owners to assume responsibility for the ownership and maintenance of commonly-owned property. 4. Per discussion with engineering staff, the applicant is in the process of redesigning the parking sections of this site in order to gain additional lots. If this is the case additional comments may be forth coming at the next submittal. 5. Based on changes to the plans and responses to the comments additional comments may be forth coming. If you have any questions about this transmittal, please call Terry Stevens, (520) 791-5550 ext. 2000. TLS C:\planning\cdrc\tentativeplat\S06-144tp.doc |
03/06/2007 | LOREN MAKUS | ENGINEERING | REVIEW | Denied | DATE: March 6, 2007 To: Patricia Gehlen CDRC/Zoning Manager FROM: Loren Makus, EIT Engineering Division SUBJECT: Oasis-Golf Links Tentative Plat S06-144 (Second Review) T14S, R15E, Section 27 RESUBMITTAL REQUIRED: Tentative Plat, Drainage Report The Tentative Plat and Drainage Report have been reviewed by the Engineering Division and we do not recommend approval at this time. The following review comments must be addressed. Tentative Plat Comments 1. The Solid Waste container pick-up locations are shown blocking the sidewalk. Provide container locations that don't block the sidewalks. 2. Clarify the basin top and bottom locations for both basins. Note also that the finish floor elevations for pads adjacent to the basins must be at least one foot above the expected water surface elevation. Confirm that lot 43 will comply with this requirement. 3. As previously commented, provide distance and bearing for each project boundary. The south and west boundaries do not have clearly indicated distance and bearing or curve data. Drainage Report Comments 4. Provide hydraulic analysis for the north street cross-section. The drainage report incidates that there will be a discharge of 41 cfs in the street. Submit a revised Tentative Plat and a revised Drainage Report. Include a detailed response letter, detailing how each comment has been addressed. If you have any questions, I can be reached at 791-5550 x1161 or loren.makus@tucsonaz.gov. Loren Makus, EIT Senior Engineering Associate |
03/07/2007 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES March 7, 2007 Chuck Martin Rick Engineering Company 1745 E. River Road #101 Tucson, Arizona 85718 Subject: Oasis Golf Links Tentative Plat Dear Chuck: Your submittal of January 12, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLACKLINES MUST BE FOLDED 4 Copies Revised Tentative Plat (Real Estate, Engineering, Zoning, DSD) 3 Copies Revised Landscape Plan (Engineering, Zoning, DSD ) 2 Copies Revised Drainage Report (Engineering, DSD) Should you have any questions, please call me at 791-5608 extension 1179. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 322-6956 |