Plan Number: S06-138
Parcel: Unknown

Address: Unknown

Review Status: Completed

Review Details: TENTATIVE PLAT REVIEW

Plan Number - S06-138
Review Name: TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/15/2006 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
06/19/2006 JOE LINVILLE LANDSCAPE REVIEW Denied The Landscape Section does not recommend approval of the plans at this time due to inconsistencies with adopted codes and standards. The plan was reviewed for compliance with the Land Use Code (LUC), Development Standards (DS) and other applicable standards and guidelines referred to in the comments. Revise the plans as necessary to comply.

1) Revise the landscape plan to show the locations and note the height and materials used to construct any proposed or required screen walls. DS 2-07.A.3
A wall is required on the west side of the site.

2) Revise the landscape plan to provide a twenty-five foot landscape buffer outside of the required wall on the west side of the site. C9-01-05

3) Revise the tentative plat and landscape plan to show the study area and resource area of the Rodeo Wash. Per C9-01-05, no development is allowed in the resource area.

4) Revise the development plan and landscape plan to clarify compliance with the screening requirements for loading and refuse storage areas. LUC Table 3.7.2.-I.

5) Revise the landscape plans to show the limits of grading. DS 2-07.2.2.B.5

6) Revise the native plant preservation plans to show the limits of grading. DS 2-15.3.4.A

7) Identify natural areas on the landscape and native plant preservation plans. DS 2-15.6.0

8) Update the native plant preservation plan to clarify that Lot 1 is developed. DS 2-15.2.0

9) Revise the tentative plat to show Lot 5 and Common Area "A" referred to in the title.

10) Revise the title block to include Blocks 1 & 2.

11) A vehicular use area must be provided with post barricades or wheel stop curbing designed to prevent parked vehicles from extending beyond the property lines; damaging adjacent landscaping, walls, or buildings per DS 3-05.2.3.C.
Revise the plans as necessary to indicate appropriate barriers.

12) Grading, hydrology, and landscape structural plans are to be integrated to make maximum use of site storm water runoff for supplemental on-site irrigation purposes. The landscape plan shall indicate use of all runoff, from individual catch basins around single trees to basins accepting flow from an entire vehicular use area or roof area. LUC 3.7.4.3.B

Revise the landscape plan to show the extent of supplementary irrigation in each planting area provided by water harvesting methods. Show the amount and disposition of flow and indicate drainage points from buildings and paved areas. DS 2-07.2.2.C


RESUBMITTAL OF ALL PLANS IS REQUIRED.
06/19/2006 JIM EGAN COT NON-DSD FIRE Approved
06/27/2006 FRODRIG2 PIMA COUNTY WASTEWATER Denied June 27, 2006

TO: Michael John Baker, P.E.
Floerchinger Sadler Steel Baker, Inc.

THRU: Patricia Gehlen
City of Tucson, Development Services Department

FROM: Dickie Fernández, E.I.T.
Pima County Development Services Department
Development Review Division (Wastewater)

SUBJECT: Wilmot & I-10 Commercial Center
Tentative Plat – 1st Submittal
S06-138

The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


Provide a letter from PCWWM Planning Services, written within the past 90 days, stating that treatment and conveyance system capacity for this project is available. A capacity request form may be found at http://www.pima.gov/wwm/forms/docs/CapResponseRequest.pdf.

ALL SHEETS. Add the project number, S06-138, to the title block of each sheet. This number should be shown larger or bolder than any cross-reference numbers.

SHEET 1. Please show the project reference number S01-040 that is tied to this property.

Based on the evaluation of the proposed sewer design, this project qualifies for Standard sewer connection fee rates.

Be aware that this project proposes connecting to an existing 18-inch public sewer, and thus will likely require a flow management plan at the time of construction.

SHEET 1. Revise General Note 10 to read

ON-SITE SANITARY SEWERS, EXCEPT PUBLIC SEWERS WITHIN PUBLIC SEWER
EASEMENTS OR RIGHTS-OF-WAYS, WILL BE PRIVATE AND WILL BE CONSTRUCTED, OPERATED AND MAINTAINED ON A PRIVATE BASIS. THE LOCATION AND METHOD OF CONNECTION TO AN EXISTING PUBLIC SANITARY SEWER IS SUBJECT TO REVIEW AND APPROVAL BY THE PIMA COUNTY WASTEWATER MANAGEMENT DEPARTMENT AT THE TIME OF SUBMITTAL OF PLUMBING OR BUILDING PLANS.

SHEET 2. Clearly label and show the existing BCS for the existing convenience store located on the southern section of this project. Please label it with its corresponding size.

We will require a revised set of drawings and a response letter addressing each comment. Additional comments may be made during the review of these documents.

The next submittal of this project will be the 2nd submittal. A check for the review fee of this submittal in the amount of $100.00 made out to PIMA COUNTY TREASURER must accompany the revised set of bluelines and response letter.

For any questions regarding the fee schedule, please go to http://www.pimaxpress.com/SubDivision/Documents/Fees.PDF where you may find the appropriate wastewater review fees at the bottom of page 1. If the number of sheets changes, please adjust the review fee accordingly.


If you have any questions regarding the above mentioned comments, please contact me. Sincerely,





Dickie Fernández, E.I.T.
Telephone: (520) 740-6947

Copy: Project
06/30/2006 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Denied 4350 E. Irvington Road, Tucson, AZ 85714
Post Office Box 711, Tucson, AZ 85702


WR# 164648 June 30, 2006



Floerchinger, Sadler, Steele, Baker, Inc.
ATTN: Mr. Michael John Baker, PE
326 S. Convent
Tucson, AZ 85701

Dear Mr. Baker:

SUBJECT: WILMOT & I-10 COMMERCIAL CENTER
S06-138

Tucson Electric Power Company (TEP) has reviewed the plan submitted June 15, 2006. TEP is unable to approve the plan at this time. TEP facilities do not appear to be properly indicated on the plan. In order for TEP to approve the plan, the facilities and easements must be depicted on the plans.

Enclosed is a copy of a TEP facility map showing the approximate location of the existing facilities. All cost associated with the relocation of the facilities in conflict will be billable to the developer.

Please resubmit two revised bluelines to the City of Tucson for TEP’s review. You may contact the area Designer, Todd Stocksdale, at (520) 917-8715 if you have any questions.

Sincerely,


Ann Slusser
Scheduling Coordinator
Design Build

Enclosure
cc: P. Gehlen, City of Tucson, (by e-mail)
F. Rodriguez, City of Tucson (by e-mail)
T. Stocksdale, TEP
07/12/2006 KAY MARKS PIMA COUNTY ADDRESSING Denied 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S06-138 WILMOT & I-10 COMMERCIAL CTR/TENTATIVE PLAT
DATE: 7-12-06



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:

Correct Lots 1 through 5 to 1 through 4 and add Blocks 1 and 2 in Title Block on sheet 2.

Label an approval name for the Public street on Final Plat.









es
07/12/2006 JCLARK3 ENV SVCS REVIEW Approv-Cond * No known landfill with in 1000 feet of this development.
* Enclosures require sidewall protection and doors.
Note: The plan shows three resturants. Resturants have most of their supplies shipped to them in recycleable containers. No mentioned of recycling for the project.
Resturants usually have a grease container. The container coanot be stored with in the ten foot clear area of the enclosure.
07/14/2006 JOSE ORTIZ COT NON-DSD TRAFFIC Denied July 14, 2006
ACTIVITY NUMBER: S06-138
PROJECT NAME: Wilmot & I-10 Commercial Ctr.
PROJECT ADDRESS: 7710 S Wilmot Rd
PROJECT REVIEWER: Jose E. Ortiz PE, Traffic Engineer

Resubmittal Required: Traffic Engineering does not recommend approval of the Tentative Plat; therefore a revised Tentative Plat and a Traffic Impact Analysis is required for resubmittal.

The following items must be revised or added to the plat.

1. Include a response letter with the next submittal that states how all comments have been addressed.

2. Provide the Traffic Impact Analysis as required per Rezoning Condition C9-01-05 (note 6 on the Tentative Plat)

3. Confirm that rezoning condition note 5 has been considered in the design (NOTE 5: "WILMOT ROAD SHALL BE WIDENED TO PROVIDE A SOUTHBOUND RIGHT TURN LANE INTO THE NORTHERN MOST ACCESS OPENING AND A CONTINUOUS NORTHBOUND LEFT TURN LANE FOR BOTH ACCESS OPENING).

4. Ensure that rezoning condition note 4 has been considered in the design. Label the ADOT freeway ramp to verify that 250' clearance has been provided.



If you have any questions, I can be reached at 791-4259 x305 or Jose.Ortiz@tucsonaz.gov
07/18/2006 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Denied DEPARTMENT OF URBAN PLANNING & DESIGN

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

S06-138 Wilmot & I-10 Comm. Ctr. 07/17/06

() Tentative Plat
( ) Development Plan
() Landscape Plan
( ) Revised Plan/Plat
( ) Board of Adjustment
( ) Other

CROSS REFERENCE: C9-01-05

NEIGHBORHOOD PLAN: Rincon Southeast Subreg. Plan

GATEWAY ROUTE: N/A

COMMENTS DUE BY: 7/14/06

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

( ) No Annexation or Rezoning Conditions, Not an RCP - No Comment
( ) Proposal Complies with Annexation or Rezoning Conditions
( ) RCP Proposal Complies With Plan Policies
() See Additional Comments Attached
( ) No Additional Comments - Complies With Planning Comments Submitted on:
() Resubmittal Required:
() Tentative Plat
( ) Development Plan
() Landscape Plan
( ) Other – Elevations and Color Palette

REVIEWER: J. Hershenhorn 791-4505 DATE: 7/`4/06


Wilmot & I-10 Commercial Center
S06-138


As per rezoning condition 1.a., please show a minimum 25-foot wide landscape border along the south and west property lines, on both the tentative plat (TP) and landscape plan (LP) – the only one shown is on the west boundary, sheet 2 of the TP. Please show the required masonry walls along the south and west property lines, on the TP and LP. Provide wall design details, and show the varied alignment on the plans to demonstrate compliance with rezoning condition 14.

As per rezoning condition 1.d., please provide crosswalks aligned in an east-west direction crossing the pedestrian area access lanes (PAALs) to provide a continuous pedestrian system on the north and south sides of the public street. Please provide at least one crosswalk, of a different texture, color, and/or material, aligned in a north-south direction and connecting areas on the north and south of the public street. Because it will be a public street, the crosswalk must be designed and constructed in accordance with applicable City standards. Show on both the TP and LP.

As per rezoning condition 8, prior to final plat approval, please submit documentation sufficient to demonstrate that the blanket cross-access easement has been provided.

Regarding rezoning conditions 12 and 13, have the Rodeo Wash channel improvements been constructed? Who are the “others”? Please clarify how the site design addresses these rezoning conditions.

Regarding rezoning condition 14, please clearly show the locations of all masonry walls. Are there any in addition to the 30-inch screen walls shown on sheet L-1? According to rezoning condition 1.a., walls are required along the south and west boundaries. For all walls that will be greater than 75 feet long and 3 feet high, please show the varied alignment on the plans, as well as trees or shrubs that will be planted in the voids created by the variations. All screen walls must be decorative. Please provide a wall detail identifying the decorative pattern, on the TP or LP.

Please provide color elevations to demonstrate compliance with rezoning condition 15. If that isn’t possible at this time, please indicate when that information will be available.

What is planned to delineate the transition between the PAAL and undeveloped areas to the west of Lot 2?
07/21/2006 PETER MCLAUGHLIN ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Center
Plans Coordination Office

FROM: Peter McLaughlin
Senior Planner

FOR: David Rivera
Principal Planner

PROJECT:
S06-138

Wilmot & I-10 Commercial Center
Tentative Plat/Development Plan

TRANSMITTAL: July 21, 2006
DUE DATE: July 14, 2006

1. An applicant has one (1) year from the date of application to obtain approval of a tentative plat that complies with zoning and other development requirements in effect at the time of application. This tentative plat must be approved on or before June 14, 2007.

2. Fill in the S06-138 number near the title block in the lower right hand corner of all sheets of the plat, landscape and NPPO plans.
DS 2-03.2.2.B.1

3. Based on rezoning condition #1, the title block should indicate that this is a "tentative plat/development plan". DS 2-03.2.4.U

4. Add the lot area and actual FAR to the Lot Data Table for Lot 1 (the existing convenience store). DS 2-05.2.4.M

5. The title block on sheet 1 of 2 reads "Lots 1-4 and Blocks 1&2 but the title block on sheet 2 of 2 reads Lots 1-5 and common area "A". Revise to be consistent and accurate. If common area is proposed it must be labeled clearly with its letter designation on the plat. Enclose any proposed common area(s) with a solid line. Include dimensions and square footages of each common area on the plat.
DS 2-03.2.4.C

6. With a proposed building height of 40 feet, the MS&R street yard setback for the proposed restaurant located on lot 2 is not met. The required setback is the greater of 21 feet and the height of exterior structure wall measured from back of MS&R future curb. Revise drawing to demonstrate compliance with LUC 3.2.6.5.
LUC 3.2.6.5

7. Dimension the depth of the vehicle backup spur located at the east end of lot 2. A minimum 3-foot deep backup spur is required and a minimum of 3 feet is required between the end of the spur and any obstruction to allow for vehicle overhang.
DS 3-05.2.2.D

8. Provide a copy of blanket cross access agreement described in rezoning condition 8
DS 2-05.2.4.U

9. Demonstrate compliance with rezoning condition 14 by detailing any proposed walls on the plan, including their height and linear footage, materials, and their required variations in alignment. Walls visible from the public right-of-way must be constructed with at least one of the decorative materials listed. In addition, all walls greater than 75 feet in length and 3 feet in height shall be built with alignments that incorporate jogs, curves, notches, etc. and include trees or shrubs in voids created by the variations. DS 2-05.2.4.U
DS 2-05.2.4.N

10. Revise the vehicle parking calculations for Lots 2, 3 and 4 to list the number of vehicle spaces provided. DS 2-05.2.4.P

11. Demonstrate compliance with rezoning conditions 12, 13 and 20 by delineating and dimensioning the resource area for Rodeo Wash. DS 2-05.2.4.U

12. A copy of proposed CC&R's must be provided to the Zoning Review Section for review and approval prior to approval of the final plat. The CC&R's must meet the criteria of DS 2-03.6.6.

13. Detail any proposed freestanding lighting on the plat to demonstrate compliance with rezoning condition 17. DS 2-05.2.4.U

14. Label the location, height, dimensions and materials of all freestanding signs to demonstrate compliance with rezoning condition 16, which requires that signage be co-located and integrated to improve the site appearance and sign readability. Provide sign elevation drawings. DS 2-05.2.4.U
DS 2-05.2.4.N

15. Provide exterior elevation drawings for the proposed buildings to demonstrate compliance with rezoning condition 15. DS 2-05.2.4.U

16. All requested changes must be made to the Development Plan/Tentative Plat and Landscape Plan.
DS 2-07.2.1.A


If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608.


RESUBMITTAL OF THE FOLLOWING ITEMS IS REQUIRED: revised development plan, landscape plan, detailed and dimensioned color building and sign elevation drawings.
08/07/2006 ELIZABETH EBERBACH ENGINEERING REVIEW Approved TO: Patricia Gehlen; CDRC Coordinator
FOR: FSSB Engineering
SUBJECT: Wilmot/I-10 Commercial Center Tentative Plat submittal Engineering Review
REVIEWER: Elizabeth Eberbach
ACTIVITY NUMBER: S06-138

SUMMARY: The Tentative Plat, Drainage Report, Landscape documents, and fax dated 7AUG06 were reviewed. Development Services Department Engineering Division recommends approval of the Tentative Plat. The Drainage Report was reviewed for Tentative Plat purposes only. The grading plan will require further details for basin and the weir outlet, show further information regarding how water harvesting is utilized, with a Geotechnical Report that provides additional percolation test results. If you have questions or would like to set up a meeting, call me at 791-5550, extension 2204.

Elizabeth Eberbach, PE
Civil Engineer
Engineering Division
Development Services
08/09/2006 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES
***REVISED***

November 9, 2006

Michael John Baker, P.E.
Floerchinger, Sadler, Steele, Baker Inc.
326 South Covent
Tucson, AZ 85701

Subject: S06-138 Wilmot & I-10 Commercial Center Tentative Plat

Dear Mike:

Your submittal of June 15, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLUELINES MUST BE FOLDED

12 Copies Revised Tentative Plat ( ESD, TEP, Engineering, Addressing, DUPD, Wastewater, Traffic, Real Estate, ADOT, Landscape, Zoning, DSD)

5 Copies Revised Landscape Plan (Landscape, DUPD, Zoning, Engineering, DSD)

2 Copies Revised NPPO Plans (Landscape, DSD)

2 Copies Color Elevations (DUPD, DSD)

Two additional review agencies will be added to the second review. Due to the proximately to I-10, ADOT will be required to review the plans. City of Tucson Real Estate will also need to look at the resubmittal.

DUE TO THE REVISED REZONING CONDITIONS ADOPTED 11/7/2006, ENGINEERING HAS BEEN ADDED BACK TO RESUBMITTAL REQUIREMENTS.

Should you have any questions, please call me at 791-5608 ext. 1179.

Sincerely,


Patricia Y. Gehlen
CDRC Manager