Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Plan Number: S06-125
Parcel: Unknown

Review Status: Completed

Review Details: FINAL PLAT REVIEW

Plan Number - S06-125
Review Name: FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/08/2008 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
02/13/2008 CDRC1 PIMA COUNTY WASTEWATER Approv-Cond February 13, 2008

To: Ron Peetz
AmericaBuilt Development, Inc.


Thru: Patricia Gehlen, CDRC Manager
City of Tucson Development Services Department

____________________________________
From: Tom Porter, Sr. CEA (520-740-6579), representing the Pima County
Departments of Wastewater Management and Environmental Quality

Subject: Rincon Knolls
Lots 1-500 and Common Areas "A"-"E"
Final Plat - 1st Submittal
S06-125

The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.

1. Sheet 1(Phase I/II/III/IV):In the Dedication Block, fourth paragraph, third line after the word PUBLIC add the words ,PIMA COUNTY.
2. Sheet 1(Phase I/II/III/IV): Fill in the blank for Trust No..

3. We will send to your office via e-mail, a .pdf file containing a Sewer Service Agreement for the proposed number of residential lots. Three originals will need to be printed out from this file for notarized signatures by the Owner of Record. The three signed originals of the Agreement must be returned to this office in order to satisfy the necessary requirements needed to approve the Mylars of the Final Plat.

Subject to the above, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the final plat. The required revision(s) may be shown on the Mylars.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.

If you have any questions regarding the above mentioned comments, please contact me .
02/20/2008 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Denied SUBJECT: RINCON KNOLLS

Lots 1-226

S06-125



Tucson Electric Power Company (TEP) has received the Final Plat for
review February 8, 2008. TEP is unable to approve the plat at this
time.



When the tentative plat has been approved by Pima County submit to my
attention a copy of the signed Approved Tentative Plat. TEP will
provide an electrical design within fifteen (15) working days upon
receipt of the plat and the required additional plans. The completion
of the electrical design is necessary to determine our easement
requirements and review the final plat.



Additional plans necessary for preparation of the design are: building
plans including water, electrical, landscape, sidewalk and paving plans.
Also, submit the AutoCAD version of the plat on a CD or email to
lcastillo@tep.com <mailto:lcastillo@tep.com> .



Electronic AutoCAD Plan format:

1. An Electronic AutoCAD plan must be complete and identical to the
official hard copy (paper) project (subdivision, commercial) plat.

2. The AutoCAD plan must be a civil site plan drawing. (The
majority of time an electrical site plan drawing does not have the
required information.)

3. A single AutoCAD plan drawing containing all the layers should
be submitted.

4. AutoCAD plan should be in DWG format.

5. AutoCAD Version can be 2007 or lower.

6. 2D only, not 3D (Please take out reference images and 3D
images.)

7. Please take out the topography Layer.

8. Layers relate to a unique set of CAD features within the
drawing. (For example all lot lines should be on one layer, street
centerlines another layer.)

9. Include the required Layers: Lot Lines, Right of Way lines,
Street Centerlines, Buildings, Curbs, Basin, Section Lines, Boundary
of Property, Footages, Bearings, Lot Numbers, Street Names, and Tie Down
(Section or Quarter Pins.)

10. At least three tie points are required; one must be a Section or a
Quarter pin and the others may be street intersections or lot corners.
Bearings and distances must be designated from the tie points.

11. Please include the Boundary Line of Property. It must be
designated with bearings and distances.

12. Any special fonts, X-REFs, or attachments should be submitted along
with the CAD drawing.



Please contact me at (520) 917-8745 if you have any questions.


Liza Castillo, Right of Way Agent
Tucson Electric Power Co.
Unisource Energy Services
offc-(520) 917-8745
fax-(520) 545-1416
lcastillo@tep.com
02/25/2008 PGEHLEN1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Approved
03/06/2008 KAY MARKS PIMA COUNTY ADDRESSING Denied 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S06-125 RINCON KNOLLS/FINAL PLAT
DATE: 3/05/08



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:

Rincon Knolls Lots 1-226, Blocks A, B, C will be recorded as The Final Plat for S06-125 and will need to be recorded before Blocks A, B and C can be recorded as Resubdivisions.

Note: The Resubdivision of Blocks A, B and C will each need to be assigned a new Project number.

On Sheet 7 of Final Plat Lots 1-222, Blocks A, B, C, correct Quail Wash Canyon Lane to Adam Camp Trail.

Delete Circle from Adam Camp Trail on Sheets 11, 12 & 13.

A Resubdivision of Block “A”
1. Label new project number on all sheets.
2. Delete Administrative Address. A new address will be assigned when this resubdivision is recorded.
3. The Title Block will need to include the recording Book and Page for Rincon Knolls, Lots 1-226, Blocks A, B & C.





A Resubdivision of Block “B”
1. Label new Project number on all sheets.
2. Delete Administrative Address. A new address will be assigned when this resubdivision is recorded.
3. The Title Block will need to include the recorded Book and Page for Rincon Knolls, Lots 1-226, Blocks A, B & C.
4. Correct Lauren Canyon Way to Lauren Canyon Place on Sheets 7 and 8.

A Resubdivision of Block “C”
1. Label new Project number on all sheets.
2. Delete Administrative Address. A new address will be assigned when this resubdivision is recorded.
3. The Title Block will need to include the recorded Book and Page for Rincon Knolls Lots 1-226, Blocks A, B & C.
4. Label Rincon Knolls Loop on Sheet 3.
5. Label Rocking Lazy A Ranch Place on Sheets 6 and 8.
6. Correct Rocking Lazy A Ranch Circle to Rocking Lazy A Ranch Place on Sheet 7.
03/10/2008 FRODRIG2 COT NON-DSD REAL ESTATE Denied S06-125 Rincon Knolls: Final Plat Review
-Request "DEDICATION" title concerning beneficiary information be changed to "BENEFICIARY" on each Sht. 1 of Phases I-IV, per C.O.T. Development Standard No. 2-03.0, Platting Procedures, paragraph 6.3.C.
-Request dispensation of 30'-40' wide In/Egress & Utility easement along the W. boundary of SW1/4 of SW1/4, S4-T16-R16, as referred in multiple instruments, to include Dkt./Pg. 3070/612, 3096/515, 6482/104, 9111/1513 11260/1629, 12435/1388 & 12474/924. Also requested is the dispensation of in/egress easement w/in S4-T16-R-16 in reference to Dk./Pg. 8655/423.

Regards,
Andy Steuart
Property Agent
Real Estate Program
City of Tucson
201 N. Stone Ave. 6th Fl.
Tucson, Arizona 85701
(O) 520.837.6715
(F) 520.791.5641
andy.steuart@tucsonaz.gov
03/19/2008 ED ABRIGO PIMA COUNTY ASSESSOR Approv-Cond Office of the Pima County Assessor
115 N. Church Ave.
Tucson, Arizona 85701

BILL STAPLES
ASSESSOR




TO: CDRC Office
Subdivision Review
City of Tucson (FAX# 791-5559)

FROM: Gary Ault, Mapping Supervisor
Pima County Assessor’s Office
Mapping Department

DATE: March 18, 2008


RE: Assessor’s Review and Comments Regarding Final Plat
S06-125 Rincon Knolls T161604 (LOTS 1-226)

* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

Plat meets Assessor’s Office requirements.
___X____ Plat does not meet Assessor’s Office requirements.


COMMENTS: PLEASE MAKE THE FOLLOWING ADJUSTMENTS BEFORE RECORDING:
ALL COMMON AREAS SHOULD BE BOUNDED BY SOLID LINES.
ADD SQUARE FOOTAGE TO EACH COMMON AREA ON EVERY SHEET.

NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.



ROSANNA WERNER
03/19/2008 ED ABRIGO PIMA COUNTY ASSESSOR Approv-Cond Office of the Pima County Assessor
115 N. Church Ave.
Tucson, Arizona 85701

BILL STAPLES
ASSESSOR




TO: CDRC Office
Subdivision Review
City of Tucson (FAX# 791-5559)

FROM: Gary Ault, Mapping Supervisor
Pima County Assessor's Office
Mapping Department

DATE: March 25, 2008


RE: Assessor's Review and Comments Regarding Final Plat
S06-125 Rincon Knolls T161604

* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

X Plat meets Assessor's Office requirements.
_______ Plat does not meet Assessor's Office requirements.


COMMENTS: Thank you for your submittal. Per phone conference with Mr. Yellowhair, the boundaries for the common areas will be made solid and the square footage will be in tables on each sheet.
If there are any questions, please contact Susan King at 740-4391 or Roseanna Werner at 740-4390.

NOTE: THE ASSESSOR'S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.





Susan King
03/20/2008 HEATHER THRALL ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department, Plans Coordination Office

FROM: Heather Thrall, Senior Planner

PROJECT: S06-125, Rincon Knolls, 10495 S. Millicent Trail
Final Plat, all 4 phases reviewed (each will be recorded separately)
1st review

TRANSMITTAL DATE: March 18, 2008

DUE DATE: March 10, 2008

COMMENTS:

1. An applicant has one (1) year from the date of approval of tentative plat to obtain approval of a final plat that complies with zoning and other development requirements in effect at the time of application. This final plat must be approved and recorded on or before September 18, 2008.

2. This project was reviewed for content specified in DS 2-03, final plat requirements.

3. As there are four separate phases to the overall subdivision, each phase is a separate final plat that is recorded. As a courtesy, staff agreed to review all four phases of the project in one submittal package. For clarity of the review comments, they are provided separately for each "phase".

4. I acknowledge the CCRs have been received, and zoning has found sufficient notes in the CCRs to provide for common area maintenance by the HOA, and for proper 'annexation' of all 4 phases of the subdivision into the same HOA agreements. A copy of the CCRS for each phase should be submitted with each future final plat submittal - see comment 2 under phase 2 review.

PHASE 1

1. Per DS 2-03.6.3.D, in the approval paragraph;
A) fill in the name of the city clerk as Roger W. Randolph on the first line.
B) on the second line, after the word "Tucson", add a comma and then the word "Arizona" followed by a second comma

2. Per DS 2-03.6.3.D, in the recordation paragraph:
A) in the second line, under State of Arizona, write in "County of Pima" rather than Pima County
B) in the 4th line, provide a comma before the year
C) in the 4th line, provide a comma after the year
D) in the 5th line, provide a comma after the word "seal"

3. Per DS 2-03.6.4.C, regarding common areas:
A) for phase 1, all common areas outside blocks A, B & C need to be shown distinctly with heavier lines on sheet 1
B) for phase 1, any common area that will be contained within block A, B & C will be shown on the phase of development for that block. In the title block for phase I, please ensure the removal of references to common areas that are within blocks A, B & C - like common area "F", which is in phase 2.

C) on phase 1, sheet 1, label the smaller area at the very far west subdivision boundary (towards the top of the drawing) between phases 2 & 3 as additional common area "B2"

D) is the phase line correct on sheet 1? On the tentative plat, it shows the phase line as being to the east of lot 80, but I see it as going just to the west of lot 80 on sheet 1.

E) if the phase line is correct on sheet 1, please remove reference to common area D5, as it appears it would then be in phase 2 development.

F) common area "I" appears to be outside of any particular block, and thus should be shown depicted on the plat for phase 1.

G) all common areas - including roads - need to be delineated as to where they begin/end and identified on the actual plat pages. I see the roadway common areas delineated on the first sheet, thank you - and I acknowledge the chart on sheet 2, thank you. (I see the square footage data for the common areas on the chart, don't worry about providing them on the subsequent plat sheets)

4. The final plat document is a very precise document as to the information it should contain. While I appreciate your efforts to include all the general notes and rezoning conditions on sheet 2 of phase 1, these notes are not required - as you've provided the minimum notes for the development on sheet 1 under General Notes. Please remove all notes on sheet 2 that are not part of the listed notes needed for the final plat, under DS 2-03.

5. Even though zoning does not review for the dedication paragraph, I noted a concern - the dedication is for all street to the public. These are not public, but private streets, and thus no dedication of them is needed.

PHASE 2 COMMENTS:

1. Please check the location of the phase lines to ensure they match what is shown on the tentative plat. It appears lot 80, for example will be in phase 2, when I believe the line should show lot 80 in phase 1 and the roadway in phase 2 in this area. Clarify.

2. The subdivision phases are each going to be recorded as their own separate final plat, therefore, when they are resubmitted, they will be assigned a new subdivision number at the bottom right near the title block - please make a little room for the new subdivision number. Please place the words "reference tentative plat" next to the provided subdivision number of S06-125.

3. Per DS 2-03.6.2.A, the gross area of just Phase II subdivision should be listed, not the full size of Rincon Knolls overall, as Phase I took care of that.

4. Per DS 2-03.6.3.D, in the approval paragraph;
A) fill in the name of the city clerk as Roger W. Randolph on the first line.
B) on the second line, after the word "Tucson", add a comma and then the word "Arizona" followed by a second comma

5. Per DS 2-03.6.3.D, in the recordation paragraph:
A) in the second line, under State of Arizona, write in "County of Pima" rather than Pima County
B) in the 4th line, provide a comma before the year
C) in the 4th line, provide a comma after the year
D) in the 5th line, provide a comma after the word "seal"

6. Per DS 2-03.6.5.C, regarding common areas:
A) Phase I final plat covered development for phase 1, all blocks A, B & C - and all common areas outside the blocks. In the title block, please remove references to blocks B & C and the common areas within them - as well as removing reference to the common areas outside any blocks. The only common area references to be in the title block should be those within this phase.

B) Common areas I and B2 appear to be outside this Phase 2, and separate from blocks B & C. Please remove reference to them in the common area calculations for phase 2 as well as the title block.

C) all common areas - including roads - need to be delineated as to where they begin/end and identified on the actual plat pages. I see the roadway common areas delineated on the first sheet, thank you - and I acknowledge the chart on sheet 2, thank you. (I see the square footage data for the common areas on the chart, don't worry about providing them on the subsequent plat sheets)

7. The final plat document is a very precise document as to the information it should contain. While I appreciate your efforts to include all the general notes and rezoning conditions on sheet 2 of phase 1, these notes are not required - as you've provided the minimum notes for the development on sheet 1 under General Notes. Please remove the notes on sheet 2 that are not part of the listed notes needed for the final plat, under DS 2-03.

8. Even though zoning does not review for the dedication paragraph, I noted a concern - the dedication is for all street to the public. These are not public, but private streets, and thus no dedication of them is needed.

PHASE 3

1) The subdivision phases are each going to be recorded as their own separate final plat, therefore, when they are resubmitted, they will be assigned a new subdivision number at the bottom right near the title block - please make a little room for the new subdivision number. Please place the words "reference tentative plat" next to the provided subdivision number of S06-125.

2. Per DS 2-03.6.3.D, in the approval paragraph;
A) fill in the name of the city clerk as Roger W. Randolph on the first line.
B) on the second line, after the word "Tucson", add a comma and then the word "Arizona" followed by a second comma

3. Per DS 2-03.6.3.D, in the recordation paragraph:
A) in the second line, under State of Arizona, write in "County of Pima" rather than Pima County
B) in the 4th line, provide a comma before the year
C) in the 4th line, provide a comma after the year
D) in the 5th line, provide a comma after the word "seal"

4. Per DS 2-03.6.5.C, regarding common areas:
A) Phase I final plat covered development for phase 1, all blocks A, B & C - and all common areas outside the blocks. In the title block, please remove references to block C and the common areas within them - as well as removing reference to the common areas outside any blocks. The only common area references to be in the title block should be those within this phase.

B) Common areas I and B2 appear to be outside this Phase 2, and separate from blocks A, B & C. Please remove reference to them in the common area calculations for phase 2 as well as the title block.

C) common areas noted in the tentative plat for phase 2 do not match with regards to the labeling and it appears some small common areas, such as drainages, etc. within the boundaries of larger common areas - are missing on sheet 1 - see common area D12 on the tentative. Please revisit the tentative plat and compare to ensure all common areas are shown on the final plat.

D) all common areas - including roads - need to be delineated as to where they begin/end and identified on the actual plat pages. I see the roadway common areas delineated on the first sheet, thank you - and I acknowledge the chart on sheet 2, thank you. (I see the square footage data for the common areas on the chart, don't worry about providing them on the subsequent plat sheets)

5. The final plat document is a very precise document as to the information it should contain. While I appreciate your efforts to include all the general notes and rezoning conditions on sheet 2 of phase 1, these notes are not required - as you've provided the minimum notes for the development on sheet 1 under General Notes. Please remove the notes on sheet 2 that are not part of the listed notes needed for the final plat, under DS 2-03.

6. Even though zoning does not review for the dedication paragraph, I noted a concern - the dedication is for all street to the public. These are not public, but private streets, and thus no dedication of them is needed.

PHASE 4

1. The subdivision phases are each going to be recorded as their own separate final plat, therefore, when they are resubmitted, they will be assigned a new subdivision number at the bottom right near the title block - please make a little room for the new subdivision number. Please place the words "reference tentative plat" next to the provided subdivision number of S06-125.

2. Per DS 2-03.6.3.D, in the approval paragraph;
A) fill in the name of the city clerk as Roger W. Randolph on the first line.
B) on the second line, after the word "Tucson", add a comma and then the word "Arizona" followed by a second comma

3. Per DS 2-03.6.3.D, in the recordation paragraph:
A) in the second line, under State of Arizona, write in "County of Pima" rather than Pima County
B) in the 4th line, provide a comma before the year
C) in the 4th line, provide a comma after the year
D) in the 5th line, provide a comma after the word "seal"

4. Per DS 2-03.6.4.C, regarding common areas:
A) common areas B1& B6 appear to be NUOS outside phase IV, and should be shown on phase I final plat only.

B) on sheet 1, a common area C12 is shown near lot 502 - however, the final plat sheet 4 and the common areas listed on sheet 2 show this common area identified as C10 - please correct.

C) on sheet 1, a common area 11 is shown across from lot 495, however, the final plat sheet 4 and the common areas listed on sheet 2 show this common area identified as C9 - please correct.

D) remove reference to common areas F, H and I in the title block.

E) all common areas - including roads - need to be delineated as to where they begin/end and identified on the actual plat pages. I see the roadway common areas delineated on the first sheet, thank you - and I acknowledge the chart on sheet 2, thank you. (I see the square footage data for the common areas on the chart, don't worry about providing them on the subsequent plat sheets
5) The final plat document is a very precise document as to the information it should contain. While I appreciate your efforts to include all the general notes and rezoning conditions on sheet 2 of phase 1, these notes are not required - as you've provided the minimum notes for the development on sheet 1 under General Notes. Please remove the notes on sheet 2 that are not part of the listed notes needed for the final plat, under DS 2-03.

6. Even though zoning does not review for the dedication paragraph, I noted a concern - the dedication is for all street to the public. These are not public, but private streets, and thus no dedication of them is needed.

PLEASE NOTE: FURTHER REVIEW COMMENTS MAY BE FORTHCOMING, DEPENDING UPON THE RESPONSES PROVIDED. I may be reached at Heather.Thrall@tucsonaz.gov or at 520-837-4951.

If you have any questions about this transmittal, please call (520) 791-5608.


C:\planning\cdrc\finalplat\S06-125 rincon knolls fp all phases.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat.
03/28/2008 LOREN MAKUS ENGINEERING REVIEW Denied DATE: March 28, 2008

To: Patricia Gehlen
CDRC/Zoning Manager
FROM: Loren Makus, EIT
Engineering Division

SUBJECT: Rincon Knolls
Final Plat S06-125 (First Review)
T16S, R16E, Section 04

RESUBMITTAL REQUIRED: Final Plat

The Final Plat has been reviewed by the Engineering Division and we do not recommend approval at this time. The following items must be addressed before the plat can be approved.

1. The final plat, as proposed, needs to be submitted as separate projects. The initial submittal must include the complete project area. The boundaries of Blocks A, B and C and all common areas listed in the title block will need to be fully described with distances and bearings. The additional phases then can be addressed as re-subdivisions of the blocks defined in the plat. Care should be taken to include in the title block only the descriptions for common areas and other areas that are defined by the plat.
2. Change the title of the second "dedication" to "Beneficiary."
3. Clarify in the Dedication that the dedication of roads to right of way doesn't include the private streets.
4. Remove the general notes and rezoning conditions from sheet 2. Only the notes that are required for the final plat should remain. Tentative plat notes should be removed.
5. Clearly tie the boundaries of the WASH Study areas to a project corner with distances and bearings.

If you have any questions, I can be reached at 520.837.4927 or loren.makus@tucsonaz.gov.
Please note that I am available to walk-in customers before 10 am on Mondays, Wednesdays and Fridays and while I am on the counter. If you wish to see me at other times please make an appointment.

Loren Makus, EIT
Senior Engineering Associate
04/01/2008 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

April 1, 2008

Merwin Yellowhair
Arrowhead Engineering, Inc.
1685 South San Todaro Place
Tucson, Arizona 85713

Subject: S06-125 Rincon Knolls Final Plat

Dear Merwin:

Your submittal of February 8, 2008 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

8 Copies Revised Final Plat (Wastewater, TEP, Addressing, Real Estate, Assessor, Zoning, Engineering, DSD)

2 Copies CC&R's (Zoning, DSD)

PLEASE NOTE THAT THE RESUBMITTAL OF THIS PLAT WILL REQUIRE FOUR (4) SEPARATE SUMBITTALS PER THE REVIEWERS COMMENTS. ONCE PLANS ARE RESUBMITTED, NEW NUMBERS WILL BE ASSIGNED TO THREE (3) OF THE FOUR (4) PHASES.


Should you have any questions, please call me at 837-4919.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 777-3438
fpresubmittal