Plan Number: S06-117
Parcel: Unknown

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - FINAL PLAT REVIEW

Plan Number - S06-117
Review Name: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/26/2007 MARILYN KALTHOFF START PLANS SUBMITTED Completed
03/01/2007 FRODRIG2 COT NON-DSD REAL ESTATE Approved S06-117 Wingate Lot 3: Resubmittal - CDRC - Final Plat Review - No comment.
03/02/2007 GLYNDA ROTHWELL UTILITIES TUCSON ELECTRIC POWER Needs Review Ferne-

I noticed that the online Plan Review Results show that TEP approved the
final plat for this project. I didn't repond to the plat submitted
02/27. The electrical design for the subdivision was just completed
04/26/07. Is it too late to add additional easements to the plat??

Liza Castillo, Right of Way Agent
Land Management
Tucson Electric Power Co.
Unisource Energy Gas & Unisource Energy Electric
PH: (520) 917-8745
RightFax: (520) 545-1416
lcastillo@tep.com <mailto:lcastillo@tep.com>
03/08/2007 STEVE SHIELDS ZONING REVIEW Approved CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office
FROM: Steve Shields
Lead Planner

PROJECT: WINGATE LOT 3 - FINAL PLAT
S06-117
3rd REVIEW

TRANSMITTAL DATE: March 8, 2007

DUE DATE: March 5, 2007

COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. 1. The Zoning Review Section approves the final plat for this subdivision. Should there be any changes requested by other CDRC members, however, the Zoning Review Section approval is void, and we request copies of those changes to insure that those changes do not affect zoning requirements.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 791-5608 ext. 1180.

C:\planning\cdrc\final plat\S06-117fp-3rd.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development plan, tentative plat, final plat, CC&R's and additional requested documents.
03/19/2007 KAY MARKS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S06-117 WINGATE LOT 3/REVISED FINAL PLAT
DATE: 3/02/07



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.



***The Pima County Addressing Section can use digital CAD drawing files when
submitted with your final plat Mylar. These CAD files can be submitted through Pima
County Addressing. The digital CAD drawing files expedite the addressing
and permitting processes when we are able to insert this digital data into the County’s
Geographic Information System. Your support is greatly appreciated.***


ES
03/22/2007 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

May 18, 2007

Ryan Stucki
Stantec Consulting Inc.
201 North Bonita Avenue
Tucson, Arizona 85745-2999

Subject: S06-117 Wingate Lot 3 Final Plat

Dear Ryan:

Your submittal of February 27, 2007 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

2 Copies Revised Final Plat (TEP, DSD)

Sorry for the confusion on this project. Please contact Liza Castillo with TEP for specific revisions needed to the final plat.





Should you have any questions, please call me at 791-5608 extension 1179.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 750-7470
fpresubmittal
03/22/2007 PAUL MACHADO ENGINEERING REVIEW Approved DS Sec.2-03.7.1.G: The final plat cannot be scheduled for Mayor and Council consideration until the financial assurances are approved. For the third party trust paperwork for the subdivision assurance, address the following remaining comments:
a) In the AGREEMENT TO CONSTRUCT SUBDIVISION IMPROVEMENTS / THIRD PARTY TRUST, address the following:
i) The assurable items list shall be corrected to include:
(1) For item 8, “… all off-site and onsite improvements as shown on …”
(2) Revise item 9, (per recent directive from the City Attorney) to read: “If any offsets against impact fees have been requested, all improvements that are the subject of the requested offsets shall be completed and accepted by the City prior to the final release of assurances. Assurances may be partially released prior to the completion of all improvements provided the releases are proportional to the level of completion of improvements.”