Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Plan Number - S06-117
Review Name: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/11/2007 | PAUL MACHADO | ENGINEERING | REVIEW | Denied | To: Patricia Gehlen DATE: January 11, 2007 CDRC/Zoning Manager SUBJECT: Wingate 3, 8903 E. Linderbrook Dr. Final Plat S06-117 (Second Review) T15S, R14E, Section 34 RESUBMITTAL REQUIRED: Final Plat. The Final Plat (FP) cannot be approved as submitted. Please address the following review comments prior to the next submittal. Final Plat: 1. Please include a response letter to the comments along with the corrected copies of the FP. 2. Submit the Subdivision Improvement Assurances for review. The following items are required in the assurance package if a Third Party Trust Agreement will be used: · Title Report · Special Warranty Deed · Trust Agreement · Amendment to Trust · Agreement to Construct Submit the above documents containing original signatures, copies of the documents and signatures will not be forwarded to the City of Tucson attorney for review. Per previous comment and per your response acknowledging that the assurances need to be resolved prior to the approval of the Final Plat. 3. Per the City of Tucson Transportation Dept., Steve Pageau, the fill slope and retaining wall located in the right-of-way will require a slope easement and a maintenance agreement on both the plat and assurances, as well as for the Ret./Det. basins. Per previous comment and per your response that this comment will be handled by a separate instrument and will be noted on the plat once it is available prior to the approval of the Final Plat. 4. Please re-label the common areas that may be used in a dual and/or single use capacity per D.S. 2-03.6.4.C. For example, a Ret./Det. Basin may also be used as a recreation facility or only a drainage facility or drainage channel and this must be reflected on the Final Plat. A key note explaining the labels could be used in conjunction with the labels, ie.: Common Area "A" - Streets Common Area "B" - Drainage/Recreation Facilities Common Area "C" - Recreation Facilities Common Area "D" - Drainage Facilities Common Area "E" - Landscaping The common areas, especially adjacent to any lot, must be designated separately from the open areas. Particularly any of the detention basins and/or drainage channels next to any lots. Per previous comment. If you have any questions, I can be reached at 791-5550 x1193 or Paul.Machado@tucsonaz.gov Paul P. Machado Senior Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 791-5550 x1193 office (520) 879-8010 fax C:/8903 E. Linderbrook Dr. FP 2 |
| 01/17/2007 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES January 17, 2007 Ryan Stucki Stantec Consulting Inc. 201 North Bonita Avenue Tucson, Arizona 85745-2999 Subject: S06-117 Wingate Lot 3 Final Plat Dear Ryan: Your submittal of December 7, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLACKLINES MUST BE FOLDED 6 Copies Revised Final Plat (TEP, Zoning, Real Estate, Addressing, Engineering, DSD) Should you have any questions, please call me at 791-5608 extension 1179. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 750-7470 fpresubmittal |
| 12/07/2006 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 12/11/2006 | STEVE SHIELDS | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Steve Shields Lead Planner PROJECT: WINGATE LOT 3 - FINAL PLAT S06-117 2nd REVIEW TRANSMITTAL DATE: December 11, 2006 DUE DATE: December 14, 2006 COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. The Zoning Review Section approves the final plat for this subdivision, subject to the following changes on the executed final plat. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised final plat to verify that those changes do not affect any zoning requirements. 2. This comment has not been addressed. Either remove the note or if you choose to have a note which addresses the proposed use then provide a proposed use per the Land Use Code. The proposed use would be "Family Dwelling "RCP-4", subject to: Sec. 3.6.1 and Sec. 3.5.7.1.E AND .F". Remove General Note 2 from the plat. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 791-5608 ext. 1180. C:\planning\cdrc\final plat\S06-117fp-2nd.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development plan, tentative plat, final plat, CC&R's and additional requested documents. |
| 12/14/2006 | KAY MARKS | PIMA COUNTY | ADDRESSING | Denied | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 KAY MARKS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: KAY MARKS, ADDRESSING OFFICIAL SUBJECT: S06-117 WINGATE LOT 3/REVISED FINAL PLAT DATE: December 13, 2006 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval: Change lot 223 to 221 on pg. 2. Change Gate Stone Drive to Loop. Change Stone Outlook Drive to Stone Lookout Drive. Change Blood Stone Drive to Bloodstone Drive (one word). Change Hail Stone Drive to Hailstone Drive (one word) jg |
| 12/14/2006 | FRODRIG2 | COT NON-DSD | REAL ESTATE | Approv-Cond | S06-117 Wingate Lot 3: Resubmittal - CDRC - Final Plat Review - R.E. has no objection as long as title transfers to "250 South L.L.C., a Delaware limited liability company" prior approval of plat. |
| 12/14/2006 | GLYNDA ROTHWELL | UTILITIES | TUCSON ELECTRIC POWER | Denied | SUBJECT: WINGATE LOT 3 Lots 1-336 S06-117 Tucson Electric Power Company (TEP) has received the final plat submitted for review December 7 , 2006. TEP is unable to approve the plat at this time. An electrical design to determine our easement requirements will be provided on the Approved Tentative Plat within thirty (30) working days upon receipt of the plat. Additional plans necessary for preparation of the design are: building plans including water, electrical, landscape, sidewalk and paving plans. Also, submit the AutoCAD version of the plat on a CD or email to lcastillo@tep.com <mailto:lcastillo@tep.com> . Should you have any questions, please contact me at (520) 917-8745. Liza Castillo Right of Way Agent Land Management Tucson Electric Power Co. (520) 917-8745 lcastillo@tep.com |