Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Plan Review Detail
Review Status: Completed
Review Details: FINAL PLAT REVIEW
Plan Number - S06-117
Review Name: FINAL PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/25/2006 | MARILYN KALTHOFF | START | PLANS SUBMITTED | Completed | |
| 10/04/2006 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Denied | SUBJECT: WINGATE LOT 3 Lots 1-336 S06-117 Tucson Electric Power Company (TEP) has received the final plat submitted for review September 25, 2006. TEP is unable to approve the plat at this time. An electrical design to determine our easement requirements will be provided on the Approved Tentative Plat within thirty (30) working days upon receipt of the plat. Additional plans necessary for preparation of the design are: building plans including water, electrical, landscape, sidewalk and paving plans. Also, submit the AutoCAD version of the plat on a CD or email to lcastillo@tep.com <mailto:lcastillo@tep.com> . Should you have any questions, please contact me at (520) 917-8745. Liza Castillo Right of Way Agent Land Management Tucson Electric Power Co. (520) 917-8745 lcastillo@tep.com |
| 10/17/2006 | STEVE SHIELDS | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Steve Shields Lead Planner PROJECT: WINGATE LOT 3 - FINAL PLAT S06-117 1ST REVIEW TRANSMITTAL DATE: 10-17-06 DUE DATE: October 20,2006 COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. An applicant has one (1) year from the date of approval of tentative plat to obtain approval of a final plat that complies with zoning and other development requirements in effect at the time of application. This final plat must be approved and recorded on or before September 24, 2007. As of this final plat review date the tentative plat has not been approved therefore the one year date of the final plat approval is based on the date of submittal of the final plat documents. Once the tentative plat has been approved the approval date of the final plat will be on one year from the tentative plat approval date. This date will be provided on a future review of the final plat. 2. Place the S06-117 subdivision case number in the lower right corner of the plat next to the title block. D.S. 2-03.6.1.K 3. Remove case numbers C9-87-19 & C12-90-4 from the plan. D.S. 2-03.6.1.K 4. Provide the following general note on the plan, "This plat is subject to the conditions of rezoning case C9-86-40, unless superseded by a subsequent rezoning ordinance" D.S. 2-03.6.2.D 5. Remove General Note 2 from the plat. 6. Zoning is unable to review the Protective Covenants at this time. The covenants submitted are for a different subdivision. Provide the covenants for Wingate Lot 3. D.S. 2-03.6.6 If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 791-5608 ext. 1180. C:\planning\cdrc\final plat\S06-117fp.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development plan, tentative plat, final plat, CC&R's and additional requested documents. |
| 10/19/2006 | FRODRIG2 | COT NON-DSD | REAL ESTATE | Denied | S06-117 Wingate Lot 3: Final Plat Review - Two items: -Per 10/17/2206 discussion w/ Thomas Vickery, KB Homes, ownership is required to transfer from the State of Arizona to 250 South LLC, a Delaware limited liability company, prior acceptance of Subject Plat. -Sht. 11 of 14, at the intersection of Street K and Linderbrook Dr., a line (8.93', 64.04' & 62.2') shows like a property line. |
| 10/20/2006 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Approved | Office of the Pima County Assessor 115 N. Church Ave. Tucson, Arizona 85701 BILL STAPLES ASSESSOR TO: CDRC Office Subdivision Review City of Tucson (FAX# 791-5559) FROM: Gary Ault, Mapping Supervisor Pima County Assessor’s Office Mapping Department DATE: October 20, 2006 RE: Assessor’s Review and Comments Regarding Final Plat S06-117 WINGATE LOT 3 T141534 * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * X Plat meets Assessor’s Office requirements. _______ Plat does not meet Assessor’s Office requirements. COMMENTS: THANK YOU FOR YOUR SUBMITTAL. IF YOU HAVE ANY QUESTIONS PLEASE CALL SUSAN KING AT 740-4391. NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED. ROSANNA WERNER |
| 10/20/2006 | KAY MARKS | PIMA COUNTY | ADDRESSING | Denied | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 KAY MARKS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: KAY MARKS, ADDRESSING OFFICIAL SUBJECT: S06-117 WINGATE LOT 3/FINAL PLAT DATE: 10/20/06 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval: Label Wingate Boulevard on Sheets 2 and 11. Ghost-in Linderbrook Drive on Sheet 9. Label interior street names. es |
| 10/27/2006 | PGEHLEN1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Passed | |
| 11/09/2006 | PAUL MACHADO | ENGINEERING | REVIEW | Denied | To: Patricia Gehlen DATE: November 8, 2006 CDRC/Zoning Manager SUBJECT: Wingate 3, 8903 E. Linderbrook Dr. Final Plat S06-117 (First Review) T15S, R14E, Section 34 RESUBMITTAL REQUIRED: Final Plat. The Final Plat (FP) cannot be approved as submitted. Please address the following review comments prior to the next submittal. Final Plat: 1. Please include a response letter to the comments along with the corrected copies of the FP. 2. Submit the Subdivision Improvement Assurances for review. The following items are required in the assurance package if a Third Party Trust Agreement will be used: · Title Report · Special Warranty Deed · Trust Agreement · Amendment to Trust · Agreement to Construct Submit the above documents containing original signatures, copies of the documents and signatures will not be forwarded to the City of Tucson attorney for review. 3. The title block of the plat must match the Subdivision Assurances verbatim. 4. Per the City of Tucson Transportation Dept., Steve Pageau, the fill slope and retaining wall located in the right-of-way will require a slope easement and a maintenance agreement on both the plat and assurances, as well as the Ret./Det. basin.+9 5. Please re-label all common areas that may be used in a dual and/or single use capacity per D.S. 2-03.6.4.C. For example, a Ret./Det. Basin may also be used as a recreation facility or only as a drainage facility or drainage channel and this must be reflected on the Final Plat. A key note explaining the labels could be used in conjunction with the labels, ie.: Common Area "A" - Streets Common Area "B" - Drainage/Recreation Facilities Common Area "C" - Recreation Facilities Common Area "D" - Drainage Facilities Common Area "E" - Landscaping 6. Complete the case no. S06-117. 7. Replace the word "clerk" under the signature line with the actual name of the clerk per D.S. 2-03.6.2.C. 8. Show the limits of the 100-year floodline…..with frequent ties to intersecting lot lines per D.S. 2-03.6.4.E. 9. Corner lots shall be designated with a star symbol indicating which street will be used for access D.S. 2-03.6.5.G. 10. At least (one) corner of subdivision will be tied to by course and distance……..per D.S. 2-03.6.5.A. 11. Please submit a copy of the subdivision boundary closure calculations. If you have any questions, I can be reached at 791-5550 x1193 or Paul.Machado@tucsonaz.gov Paul P. Machado Senior Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 791-5550 x1193 office (520) 879-8010 fax C:/8903 E. Linderbrook Dr. FP |
| 11/13/2006 | FRODRIG2 | PIMA COUNTY | WASTEWATER | Approv-Cond | November 9, 2006 To: Ryan Stucki, P.E. Stantec Consulting, Inc. Thru: Patricia Gehlen, CDRC Project Manager City of Tucson Development Services Department From: Chandubhai C. Patel, P.E. Pima County Development Services Department Development Review Division (Wastewater) Subject: Wingate Lot 3, Lots 1 Through 336 and Common Areas “A” and “B” Final Plat – 1st Submittal, S06-117 The drawings for the proposed final plat of the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. All Sheets : Add the case number SO6-117 to the title block of each sheet. This may be shown on the Mylars. SUBJECT TO THE ABOVE, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the Final Plat as received by us on September 22, 2006. Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality Department. Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating, or engaging in an activity which may cause or contribute to air pollution. If you have any questions regarding the above comments, please do not hesitate to contact me. Sincerely, Chandubhai Patel, P.E. Telephone: (520) 740-6563 CC: Project File |
| 11/14/2006 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES November 14, 2006 Ryan Stucki Stantec Consulting Inc. 201 North Bonita Avenue Tucson, Arizona 85745-2999 Subject: S06-117 Wingate Lot 3 Final Plat Dear Ryan: Your submittal of September 25, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLACKLINES MUST BE FOLDED 6 Copies Revised Final Plat (TEP, Zoning, Real Estate, Addressing, Engineering, DSD) 2 Copies Boundary Closure Calculations (Engineering, DSD) 3 Copies CC&R's (Zoning, Engineering, DSD) Should you have any questions, please call me at 791-5608 extension 1179. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 750-7470 fpresubmittal |