Plan Review Detail
Review Status: Completed
Review Details: FINAL PLAT REVIEW
Plan Number - S06-112
Review Name: FINAL PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/10/2006 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 05/16/2006 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Approved | SUBJECT: PASTINE ROAD CONDOMINIUMS S06-112 Tucson Electric Power Company has reviewed and approved the plat submitted for review May 10, 2006. Please call me at (520) 917-8745, should you have any questions. Liza Castillo Right of Way Agent Land Management Tucson Electric Power Co. (520) 917-8745 lcastillo@tep.com |
| 05/31/2006 | FRODRIG2 | PIMA COUNTY | WASTEWATER | Denied | May 31, 2006 To: Seth Ferguson, The WLB Group Thru: Patricia Gehlen, CDRC Project Manager City of Tucson Development Services Department ____________________________________ From: Michael J. Harrington, representing the Pima County Departments of Wastewater Management and Environmental Quality Subject: Pastime Road Condominiums Bldg. 166 Units 1, 2, 3 & 4, Bldg. 176 Units 1, 2, 3 & 4, Bldg. 186 Units 1, 2, 3 & 4 Final Plat - 1st Submittal S06-112 The proposed final plat for the above-referenced project has been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. This apartment to condominium project will be tributary to the Roger Road Wastewater Treatment Facility via the South Rillito - West (Central Line). The on-site sewers are existing and private, except for the public sewer G-75-17 located in a public sewer easement. No new sewers are proposed. No Capacity Response Letter is required. Add a General Note that states: THE LANDSCAPING WITHIN ALL PUBLIC SEWER EASEMENTS SHOWN HEREON SHALL BE IN ACCORDANCE WITH THE PLANTING GUIDELINES OF PC/COT STANDARD DETAIL WWM A-4. Add a General Note that states: THE ASSOCIATION OF CONDOMINIUM UNIT OWNERS SHALL NOT CONSTRUCT ANY PERMANENT STRUCTURE (I.E., MASONRY WALLS, FENCES, ETC.), ON OR THROUGH THE PUBLIC SEWER EASEMENT, WITHOUT SEPARATE WRITTEN CONSENT FROM THE PIMA COUNTY WASTEWATER MANAGEMENT DEPARTMENT. This office will require a revised set of bluelines, and a response letter, addressing these comments. Additional comments may be made during the review of these documents. Pima County Code Title 13.20.030.A.2 requires that a wastewater review fee be paid for each submittal of the final plat. The fee for the first submittal is $166 plus $50 per sheet. For the second submittal, the review fee is $50 per sheet. For all subsequent submittals, the review fee is $39 per sheet. The next submittal of this project will be the second (2nd) submittal. A check for the review fee of this submittal in the amount of $50.00 (made out to PIMA COUNTY TREASURER) must accompany the revised set of bluelines and response letter. If the number of sheets changes, please adjust the review fee accordingly. If you have any questions regarding the above mentioned comments, please contact me at the telephone number shown under my signature on the first page of this letter CC: Project File |
| 06/07/2006 | KAY MARKS | PIMA COUNTY | ADDRESSING | Denied | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 KAY MARKS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: KAY MARKS, ADDRESSING OFFICIAL SUBJECT: S06-112 PASTIME ROAD CONDOMINIUMS/FINAL PLAT DATE: JUNE 7, 2006 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval: Delete all directions on streets. Change France Terrace Townhomes Book 39, Page 22 to Page 42. Change Buildings 166, 176 & 186 to Buildings 1, 2 & 3. Addresses cannot be used as building numbers. The addresses will continue to be used but should not be shown on the plat. jg |
| 06/08/2006 | JOSE ORTIZ | ENGINEERING | REVIEW | Denied | DATE: June 12, 2006 TO: Patricia Gehlen, CDRC Manager FROM: Jose E. Ortiz, Civil Engineering SUBJECT: Engineering review of the Pastime Road Condominium Conversion Final Plat; Activity # S06-112. RESUBMITTAL REQUIRED: Final Plat Engineering has reviewed the received items and does not recommend approval of the Final Plat. 1. If applicable, show detention/retention areas in a surveyable and readily retraceable manner. DS 2-03.6.4.I 2. At least one (1) corner of the Property line will be tied by course and distance to a section corner, a quarter section corner, or an established City or County survey monument. DS 2-03.6.5.A. This tie needs to contain both a distance and bearing to the corner of the property line. 3. Label Pastime Road monument line as the Basis of Bearing on sheet 2. 4. The legend in incomplete: please include the various line-work used for this project. 5. Provide all dimensions along the exterior portion of all condo structures, and provide a dimension between the interior portion of the structure to the exterior portion of the structure. 6. Tie down one corner of each building to the property line with a bearing and distance, and ensure that the portion of property being tied into has a bearing and distance to a fixed point along the property line. If you have any questions, I can be reached at 791-5640 ext. 1191 or jose.ortiz@tucsonaz.gov Jose E. Ortiz, PE Civil Engineer |
| 06/09/2006 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Approved | Office of the Pima County Assessor 115 N. Church Ave. Tucson, Arizona 85701 BILL STAPLES ASSESSOR TO: CDRC Office Subdivision Review City of Tucson (FAX# 791-5559) FROM: Gary Ault, Mapping Supervisor Pima County Assessor’s Office Mapping Department DATE: June 9, 2006 RE: Assessor’s Review and Comments Regarding Final Plat S06-112 Pastime Road Condominiums T131325 (106-02) * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * X Plat meets Assessor’s Office requirements. _______ Plat does not meet Assessor’s Office requirements. COMMENTS: Thank you for your submittal. Per phone conference with Mr. Seth Ferguson of the WLB Group, the road information for Stone and East Pastime will be added to the plat and the square footage for the Common Elements involving the driveway, parking and open space will be added to either the general notes or to the plat. NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED. Susan King |
| 06/16/2006 | FRODRIG2 | COT NON-DSD | REAL ESTATE | Approved | S06-112 Pastime Road Condominiums: Final Plat Review - No comment. |
| 06/23/2006 | PGEHLEN1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Approv-Cond | WATER SUPPLY Tucson Water has been designated by the State of Arizona, Department of Water Resources, as having an assured water supply. This does not mean that water service is currently available to the proposed development. This development lies within the exterior boundary of Tucson Water's planned 50-year service area. Therefore, water supply is assured. WATER SERVICE The approval of water meter applications is subject to the availability of water service at the time an application is made. The developer shall be required to submit a water master plan identifying but not limited to: Water Use Fire Flow Requirements Offsite / Onsite Water Facilities Loops and Proposed Connection Points to Existing Water System Easements / Common Areas Any specific area plan fees, protected main / facility fees and / or other needed facilities' cost are to be paid by the developer. If the existing water system is not capable of meeting the requirements of the proposed development, the developer shall be fiscally responsible for modifying/enhancing the existing water system to meet those needs. This letter shall be null and void one year from the date of issuance. Issuance of this letter is not to be construed as agency approval of a water plan or as containing construction review comments relative to conflicts with existing water lines and the proposed development. If you have any questions, please call New Development at 791-4718. Sincerely, Richard S. Williamson, P.E. Manager, New Development RW:bjh |
| 07/17/2006 | TERRY STEVENS | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Terry Stevens Lead Planner PROJECT: S06-112 Pastime Road Condominiums Final Plat TRANSMITTAL: 07/17/06 DUE DATE: 06/08/06 COMMENTS: 1. The Zoning Review Section approves the final plat for this subdivision, subject to the following changes on the executed final plat. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised final plat to verify that those changes do not affect any zoning requirements. 2. DS 2-03.6.1.D In the location map, indicate the location of Pastime Road. 3. DS 2-03.6.1.K This project has been assigned the subdivision case number S06-112. Please list the case number in the lower right corner of all final plat sheets. If you have any questions about this transmittal, please call Terry Stevens, (520) 791-5550 ext. 2000. C\planning\cdrc\finaplat\S06-112fpca |
| 07/18/2006 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES July 18, 2006 Seth Ferguson WLB Group 4444 East Broadway Blvd. Tucson, AZ 85712 Subject: S06-112 - Pastime Road Condominium Final Plat Dear Seth: Your submittal of May 10, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLUELINES MUST BE FOLDED 4 Copies Revised Final Plat (Wastewater, Addressing, Engineering, DSD) Should you have any questions, please call me at 791-5608 ext. 1179. Sincerely, Patricia Y. Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 881-7492 |