Plan Number: S06-097
Parcel: Unknown

Address:
3808 N 1ST AV

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW

Plan Number - S06-097
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/08/2007 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
05/22/2007 JOE LINVILLE LANDSCAPE REVIEW Denied 1) Identify the species for each individual plant in the street landscape borders using symbols or other appropriate means.
Identify the trees in the southern part of the site and list quantities. DS 2-07.2.2

2) Submit the Native Plant Preservation Plans. Revise the landscape plans to provide a summary of native plant preservation requirements (see totals on sheet L2) and show all transplants and mitigation plantings on the drawing.
DS 2-15.3.4.B
Several plants could not be located on the landscape plan.
05/25/2007 KAY MARKS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S06-097 THE LOFTS AT VILLA SAVONNA/REVISED TENTATIVE PLAT
DATE: May 25, 2007



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.





***The Pima County Addressing Section can use digital CAD drawing files when
submitted with your final plat Mylar. These CAD files can be submitted through Pima
County Addressing. The digital CAD drawing files expedite the addressing
and permitting processes when we are able to insert this digital data into the County’s
Geographic Information System. Your support is greatly appreciated.***





jg
05/28/2007 PATRICIA GILBERT ENGINEERING REVIEW Approved TO: Patricia Gehlen; CDRC Coordinator DATE: May 28, 2007

SUBJECT: Engineering review of the Lofts at Villa Savonna Tentative Plat. The activity number is S06-097.

SUMMARY: The Tentative Plat and Drainage Report were received by Engineering on February 13th, 2007. Engineering has reviewed the received items and recommends approval of the Tentative Plat and the Drainage Report.

APPROVED: TENTATIVE PLAT, DRAINAGE REPORT
06/05/2007 KAROL ARAGONEZ ZONING REVIEW Approved CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office

FROM: Karol Aragonez
Planner

PROJECT: S06-097
The Lofts at Villa Savonna
Tentative Plat Resubmittal

TRANSMITTAL DATE: June 5, 2007

DUE DATE: June 6, 2007

COMMENTS:

The Zoning Review Section verifies that the tentative plat meets the requirements of the Land Use Code. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the corrected tentative plat to verify that those changes do not affect any zoning requirements.

If you have any questions about this transmittal, please call Karol Aragonez, (520) 791-5550, ext. 74960.

KAA S:\zoning review\karol\planning\cdrc\tentativeplat\S06-097tpr.doc
06/06/2007 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES
***REVISED***


June 13, 2007

Thomas E. Guido, P.E.
T & T Engineering, LLC.
5980 East Verde Place
Tucson, Arizona 85750

Subject: S06-097 The Lofts at Villa Savonna Tentative Plat

Dear Tom:

The above referenced plan has been CONDITIONALLY APPROVED by the Community Design Review Committee, subject to the revisions required on the mylars. Please submit the following documents for sign-off:

1 Reproducible Océ or Photo Mylar of the Plat, Landscape Plan and NPPO.

Additional blackline copies will be made from the complete set and distributed to various review agencies for their files. These copies will be ordered from the City's contracted print company and billed to you unless you already have an account at another printing company. Please let us know which printing company you would prefer to use and list them on your attached transmittal form when submitting your mylars to the CDRC office for sign-off approval. Your printing company will deliver the mylar and three (3) blackline copies to your office. If you are out of town you will need to contact the printing company for pick up or mailing arrangement options.

Please note that the final plat must be approved by Mayor and Council and recorded within one year of date of approval of the tentative plat per LUC 4.1.7.3.

TO ENSURE A MORE RAPID REVIEW OF THE MYLARS, PLEASE HAVE THE CITY OF TUCSON APPROVAL STAMP PLACED ON EACH SHEET OF THE SUBMITTAL SET, PREFERABLY IN THE LOWER RIGHT HAND CORNER NEAR THE TITLE BLOCK. THE STAMP IS LOCATED AT http://www.ci.tucson.az.us/dsd/CDRC Rezoning/CDRC/CDRC Stamp/cdrc stamp.html.

Should you have any questions, please call me at 837-4919.

Sincerely,



Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 577-0929