Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: S06-094
Parcel: Unknown

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - FINAL PLAT REVIEW

Plan Number - S06-094
Review Name: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/12/2007 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
08/09/2007 TERRY STEVENS ZONING REVIEW Approved CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Terry Stevens
Lead Planner

PROJECT: S06-094
Desert View Plaza
Final Plat

TRANSMITTAL: 08/10/07

DUE DATE: 08/09/07

COMMENTS:

1. The Zoning Review Section approves the final plat for this subdivision. Should there be any changes requested by other CDRC members, however, the Zoning Review Section approval is void, and we request copies of those changes to insure that those changes do not affect zoning requirements.

If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961


C:\planning\cdrc\finalplat\S06-094fpa.doc
09/18/2007 JASON GREEN ENGINEERING REVIEW Approv-Cond Called applicant. Need to clarify the common area in the Title Block and revise the General Note to list only the common area and the uses within. Applicant (Jean Armstrong) will set up a time after Sept 3 to come in so we can discuss what is required. This should be a simple fix that we can take care of so that they do not have to resubmit. JG
09/18/2007 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

September 18, 2007
Marty Magelli
Baker and Associates Engineering, Inc.
1636 North Swan Road, Suite 200
Tucson, Arizona 85712

Subject: S06-094 Desert View Plaza Final Plat

Dear Marty:

The above referenced project has been CONDITIONALLY APPROVED by the Community Design Review Committee. Please make any necessary corrections and submit the following documents:

(2) Title reports current within the last thirty (30) days.
(1) Executed Final Plat Double Matte Océ or Photo Mylar.
(1) * Check in the amount of $8.50 per plat page for Mayor & Council distribution made payable to the local print company of your choice or provide an account number to charge.
(1) * Check in the amount of $55.00 per plat page for recorded plat distribution made payable to the local print company of your choice or provide an account number to charge.
(1) Check made payable to "Pima County Recorder" in the amount of $20.00 per plat page plus a $4.00 handling fee, along with CC&R fees if applicable. CC&R fees are $9.00 for the first 5 pages and $1.00 for each additional page.
(1) Executed and notarized CC&R's document (if applicable).

*Please do not combine the checks for the printing charges. They are processed at different times and require separate checks. An account number is also acceptable and you can include this information on your transmittal sheet when submitting the above listed items.

Assurances (if applicable) must be reviewed by the City Attorney's Office prior to being presented to the Mayor and Council. Plats, CC&R's and assurances must be approved at the same Mayor and Council Meeting. Please expect 5-6 weeks from the date submitted to the date scheduled for Mayor and Council approval.

Should you have any questions, please call me at 837-4919.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 318-1930
Fp-approved
09/18/2007 JASON GREEN ENGINEERING REVIEW Approv-Cond DATE: September 18, 2007
SUBJECT: Final Plat for Desert View Plaza -2nd Engineering review
TO: Patricia Gehlen, CDRC Manager
LOCATION: 3943 E Valencia Road, T15S R14E Sec10 Ward 5
REVIEWERS: Jason Green, CFM
ACTIVITY: S06-094


SUMMARY: Engineering Division of Development Services Department has received, Sheet 1, 2 and 3 of the proposed Final Plat, a copy of the Covenants, Conditions, & Restriction's (CC&R's), the Title Report, and proposed Assurance Package. Engineering Division has reviewed the submitted Final Plat, CC&R's, and Assurance Package and recommends conditional approval of the Final Plat at this time. The following items need to be addressed prior to Mylar approval:


FINAL PLAT COMMENTS:

1) DS Sec.2-03.6.4.K: Revise the Final Plat to label and dimension the Common Areas that are being used as Parking Area Access Lanes (PAALs) and vehicular use areas throughout the multiphased project. These areas must be delineated on the plan per our meeting conversation with Michael McCory on September 13, 2007 to establish common areas that are for public use and for private maintenance.


GENERAL COMMENTS:

Provide the common area delineations on the Final Plat Mylar at submittal.

The revised Final Plat must address the comments provided above. Include a comprehensive response letter addressing in detail responses to all of the above comments.

If you have any questions, or to schedule a meeting, I can be reached at 837-4929.



Jason Green, CFM
Senior Engineer Associate
Engineering Division
COT Development Services