Plan Number: S06-094
Parcel: Unknown

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW

Plan Number - S06-094
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/07/2007 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
07/02/2007 JOE LINVILLE LANDSCAPE REVIEW Approved
07/09/2007 TERRY STEVENS ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Terry Stevens
Lead Planner

PROJECT: S06-094
Desert View Plaza
Tentative Plat / Development Plan

TRANSMITTAL: 07/09/07

DUE DATE: 07/05/07

COMMENTS:


1. DS 2-05.2.4.C Show and label any temporary improvements that may be needed to make the site function for each phase as one entity.

This comment has not been addressed completely. Temporary bollards or temporary curb will be required at the entrance to all parking spaces and trash enclosure located near building #10 along the phase line or change the location of the phase line.

2. DS 2-05.2.4.K Show on-site pedestrian circulation as required by the LUC utilizing location and design criteria in Development Standard 2-08.0.

This comment has not been addressed correctly. The cross walks passing through the islands located north of building #8 and west of buildings #2 and #3 are required to have truncated domes on both sides of the islands or the full depth of the island if less than 4'. (transitioning from pedestrian area to vehicular use area). See ANSI Standards 117.1-2003 Sec. 406.14.

3. DS 2-05.2.4.M Zoning acknowledges your response in regards to the ingress/egress easements being provided in the CC&Rs. Provide a note on the plan that CC&R's with cross parking and cross ingress/egress will be recorded at time of Final Plat. The following comment will remain as a reminder to the reviewer.

4. DS 2-05.2.4.P This comment has not been addressed. The handicap parking sign indicated in detail 4 cannot be located in the required 4' sidewalk area, wheel stops have been provided therefore the sign can be located out side of the 4' sidewalk area.

The minimum distance from grade to the bottom of the handicap sign is seven (7) feet not seven feet to the top of sign as indicated on detail 4. Revise.

5. Based on responses to the comments and changes to the plans further comments may be forth coming.

If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961


TLS C:\planning\cdrc\tentativeplat\S06-094tp.doc
07/11/2007 ANDY VERA ENV SVCS REVIEW Approved
07/12/2007 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

July 31, 2007

Marty Magelli, P.E.
Baker & Associates Engineering, Inc.
1636 North Swan Road, Suite 200
Tucson, Arizona 85712

Subject: S06-094 Desert View Plaza Development Plan/Tentative Plat

Dear Marty:

The above referenced development plan/tentative plat has been CONDITIONALLY APPROVED by the Community Design Review Committee. Once the necessary corrections are made per on-line, please submit the following documents for sign-off.

1 Double Matte right-reading Océ or Photo Mylar of the COMPLETE SET of the Development Plan/Tentative Plat, Landscape Plan, and the Native Plant Preservation Plan (if part of the original submittal).
AND
1 Double Matte right-reading Océ or Photo Mylar of the Development Plan/Tentative Plat.

The extra Double Matte right-reading Océ or Photo Mylar that you submit will be delivered to Pima County for permanent recording. Additional blackline copies will be made from the complete mylar set and distributed to various review agencies for their files. These copies will be ordered from the City's contracted print company and billed to you unless you already have an account at another printing company. Please let us know which printing company you would prefer to use and list them on your attached transmittal form when submitting your mylars to the CDRC office for sign-off approval. Your printing company will deliver the mylar and two (2) blackline copies to your office. If you are out of town you will need to contact the printing company for pick up or mailing arrangement options.

Please note that the final plat must be approved by Mayor and Council and recorded within one year of date of approval of the tentative plat per LUC 4.1.7.3.

TO ENSURE A MORE RAPID REVIEW OF THE MYLARS, PLEASE HAVE THE CITY OF TUCSON APPROVAL STAMP PLACED ON EACH SHEET OF THE SUBMITTAL SET, PREFERABLY IN THE LOWER RIGHT HAND CORNER NEAR THE TITLE BLOCK. THE STAMP IS LOCATED AT http://www.ci.tucson.az.us/dsd/CDRC Rezoning/CDRC/CDRC Stamp/cdrc stamp.html.

Should you have any questions, please call me at 837-4919.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/
Via fax: 318-1930
07/12/2007 JASON GREEN ENGINEERING REVIEW Approved DATE: July 12, 2007
SUBJECT: Tentative Plat/Development Plan of Desert View Plaza - 4th Engineering review
TO: Patricia Gehlen, CDRC Manager
LOCATION: 3943 E Valencia Road, T15S R14E Sec10, Ward 5
REVIEWERS: Jason Green, CFM
ACTIVITY: S06-094


SUMMARY: Engineering Division of Development Services Department has received and reviewed the re-submitted Tentative Plat, Drainage Report, Geotechnical Report, Landscape Plan, and letter of certification from ADWR on assured water supply. The Drainage Report was reviewed for Tentative Plat purposes only. Engineering Division recommends approval of the Tentative Plat at this time.

Any major changes required by other Development Services Departments will require a re-review of the Tentative Plat.

If you have any questions, I can be reached at 837-4929.


Jason Green, CFM
Senior Engineer Associate
Engineering Division
COT Development Services