Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: S06-094
Parcel: Unknown

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW

Plan Number - S06-094
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/10/2007 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
01/11/2007 JIM EGAN COT NON-DSD FIRE Approved
01/25/2007 JCLARK3 ENV SVCS REVIEW Approv-Cond * Dumpster detail enclosure doesnot show the 10' clear between the sidewall protection.
* Acess and service requirements seem to meet the Development Standards, OK.
* Recommend that the enclosure for Building 1 be constructed at a 30 degree angle to the PAAL. At the present angle there might be conflict with the parking on the opposite side of the PAAL.
01/25/2007 FRODRIG2 PIMA COUNTY WASTEWATER Approv-Cond January 25, 2007

TO: Marty Magelli, P.E.
Baker & Associates Engineering, Inc.

THRU: Patricia Gehlen, CDRC Manager
City of Tucson Development Services Department

FROM: Chandubhai C. Patel, P.E., Civil Engineering Manager
Pima County Development Services Department
Development Review Division (Wastewater)

SUBJECT: Desert View Plaza, Lots 1-7
Tentative Plat/Development Plan -3rd Submittal
S06-094


The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


SHEETS 4 & 5. Provide a 25-feet wide public sewer easement as asked for in the previous review, rather than the 24-feet wide as shown.


SUBJECT TO THE ABOVE, the Pima County Department of Environmental Quality and the Wastewater Management Department hereby conditionally approve the above referenced submittal of the development plan as received by us on January 10, 2007. The revision may be shown on the Mylars without having to resubmit the bluelines.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality Department.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating, or engaging in any activity which may cause or contribute to air pollution.


If you have any questions regarding the above comments, please do not hesitate to contact me.



Sincerely,







Chandubhai C. Patel, P.E.
Telephone: (520) 740-6563

Copy: Project File
02/05/2007 JOE LINVILLE LANDSCAPE REVIEW Approved
02/07/2007 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Approved DEPARTMENT OF URBAN PLANNING & DESIGN

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

S06-094 Desert View Plaza, L. 1-7 02/07/07

(ü) Tentative Plat/Development Plan
( ) Development Plan
(ü) Landscape Plan
( ) Revised Plan/Plat
( ) Board of Adjustment
( ) Other

CROSS REFERENCE: C9-90-18

NEIGHBORHOOD PLAN: General Plan

GATEWAY/SCENIC ROUTE: Valencia is a Gateway Route

COMMENTS DUE BY: February 8, 2007

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

( ) No Annexation or Rezoning Conditions, Not an RCP - No Comment
( ) Proposal Complies with Annexation or Rezoning Conditions
( ) RCP Proposal Complies With Plan Policies
( ) See Additional Comment Attached
(ü) No Additional Comments - Complies With Planning Comments Submitted on: 10/3/06 - see next page
(ü) No Resubmittal Required
( ) Tentative Plat/Development Plan
( ) Development Plan
( ) Other
( ) Landscape Plan

REVIEWER: J. Hershenhorn 791-4505 DATE: 2/5/07


S06-094
Desert View Plaza, L. 1-7


On 10/3/06, I asked for a pedestrian connection between the residential area north of Antrim Loop Road and the commercial area south of Antrim Loop Road.
Per discussion w/Jose Ortiz, TDOT Traffic Engineering, a crosswalk is not required. Since this was the only outstanding UPD comment, the plat is approved.
02/21/2007 TERRY STEVENS ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Terry Stevens
Lead Planner

PROJECT: S06-094
Desert View Plaza
Tentative Plat / Development Plan

TRANSMITTAL: 02/21/07

DUE DATE: 2/8/07

COMMENTS:

1. Zoning acknowledges your response and assumes you mean the Temporary Revocable Easement not an Assured Water Certificate.. Provide documentation of the approved Temporary Revocable Easement at the next submittal. The following comments will remain as a reminder for the reviewer.

The monument signs indicated in the public right of way along Alvernon will not be allowed. Relocate or remove.

2. DS 2-05.2.4.C Show and label any temporary improvements that may be needed to make the site function for each phase as one entity.

Temporary bollards will be required at the entrance to all parking spaces located near building #10 along the phase line or change the phase line.

3. DS 2-05.2.4.I All applicable building setback lines will be shown. On zoning setbacks, if the building is proposed for location at a greater distance from the property line than the required setback, show only the dimension of the distance between the building and the property line. If the setback's point of measurement is not the property line, include the distance from the property line to the point of measurement.

Provide the height of the proposed covered parking structure located along the east property line of the proposed storage center. This is required in order to calculate the required setback. (minimum 11/2 times the height of the structure)

4. DS 2-05.2.4.K Show on-site pedestrian circulation as required by the LUC utilizing location and design criteria in Development Standard 2-08.0.

Provide a minimum 4' pedestrian refuge area along buildings #11 & #12.
The cross walks passing through the islands located north of building #8 and west of buildings #2 and #7 are required to have truncated domes on both sides of the islands. (transitioning from pedestrian area to vehicular use area)

Truncated Dome (early warning systems) must be added to all access ramps where transitioning from the pedestrian area to the vehicular use area or at HC access aisles transitioning to the sidewalk area. Indicate the required minimum 24" depth.

5. DS 2-05.2.4.M Zoning acknowledges your response in regards to the ingress/egress easements being provided in the CC&Rs. Provide a note on the plan that CC&R's with cross parking and cross ingress/egress will be recorded at time of Final Plat. The following comment will remain as a reminder to the reviewer.

In order to meet the requirements of a shopping center for parking purposes it appears the personal storage has not been considered in the calculations. If this is the case, provide documentation for a cross access only agreement for lot 1 and the rest of the shopping center. Provide documentation for cross access and cross parking agreements for the rest of the Lots in the shopping center.

6. DS 2-05.2.4.P The handicap parking sign indicated in detail 4 cannot be located in the required 4' sidewalk area, wheel stops have been provided therefore the sign can be located out side of the 4' sidewalk area.

7. DS 2-05.2.4.Q Provide on the detail 3 on 2 of 5 the required clearances for the class one bicycle parking space including the access area.

8 . Based on responses to the comments and changes to the plans further comments may be forth coming.

If you have any questions about this transmittal, please call Terry Stevens, (520) 791-5550 ext. 2000.


TLS C:\planning\cdrc\tentativeplat\S06-094tp.doc
02/27/2007 JASON GREEN ENGINEERING REVIEW Denied DATE: February 27, 2007
SUBJECT: Tentative Plat/Development Plan of Desert View Plaza - 3rd Engineering review
TO: Patricia Gehlen, CDRC Manager
LOCATION: Desert View Plaza- 3943 E Valencia Road, T15S R14E Sec10, Ward 5
REVIEWERS: Jason Green, CFM
ACTIVITY: S06-094


SUMMARY: Engineering Division of Development Services Department has received and reviewed the re-submitted Tentative Plat, Drainage Report, Geotechnical Report, and Landscape Plan. The Drainage Report was reviewed for Tentative Plat purposes only. The Tentative Plat is not approved at this time. The following items need to be addressed:

TENTATIVE PLAT:

1) DS Sec.2-03.3.1.G: Submit a letter of certification from the Arizona Department of Water Resources (ADWR) on assured water supply, if the project is not served by the City of Tucson Water Department. Tentative Plat can not be approved prior to submittal of the certification letter.

2) The Assurance Package was reviewed and needs corrections as noted prior to Final Plat submittal. The following information must be provided on the original assurance package:

a) The original package must be signed and notarized prior to Final Plat approval.
b) Revise Exhibit "A" under both the Agreement to Construct Third Party and the Amendment To Trust Third Party to include the entire name of the proposed subdivision.
c) Provide the Covenants Conditions and Restrictions (CC&Rs) with the Final Plat submittal.
d) Additional comments may be forth coming at Final Plat submittal.



GENERAL COMMENTS:

Provide a letter of certification from ADWR on assured water supply at re-submittal.

If you have any questions, I can be reached at 791-5550, extension 1189.


Jason Green, CFM
Senior Engineer Associate
Engineering Division
COT Development Services
03/01/2007 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

March 1, 2007

Marty Magelli, P.E.
Baker & Associates Engineering, Inc.
1636 North Swan Road, Suite 200
Tucson, AZ 85712

Subject: S06-094 Desert View Plaza Tentative Plat

Dear Marty:

Your submittal of January 10, 2007 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLUELINES MUST BE FOLDED

3 Copies Revised Tentative Plat (ESD, Zoning, DSD)

2 Copies Revised Landscape Plans (Zoning, DSD),

2 Copies Temporary Revocable Easement (Zoning, DSD)

2 Copy Assured Water Supply for Ray Water (Engineering, DSD)

Should you have any questions, please call me at 791-5608 ext. 1179.

Sincerely,


Patricia Y. Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/
Via fax: 318-1930