Plan Number: S06-093
Parcel: Unknown

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW

Plan Number - S06-093
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/30/2006 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
07/03/2006 JIM EGAN COT NON-DSD FIRE Approved
07/06/2006 JOE LINVILLE LANDSCAPE REVIEW Denied 1) Revise the landscape plan to identify all plant symbols used. DS 2-07.2.2

2) Revise the plan to eliminate conflicts with trees and refuse storage/pickup locations. A container service area is ten (10) feet by ten (10) feet with a minimum vertical clearance of twenty-five (25) feet. DS 6-01.4.1

3) The minimum screen required along the street is 30" for vehicular use areas. Revise to provide the required screening. Select and place plants to avoid the sight visibility
triangles.

4) Provide screening for the outdoor storage areas located within one hundred feet of the street. Show and label any walls on the plat and landscape plans.
LUC 3.7.2-I
07/07/2006 JCLARK3 ENV SVCS REVIEW Approved
07/12/2006 FRODRIG2 PIMA COUNTY WASTEWATER Denied July 12, 2006

TO: Greg Carlson, P.E.
Greg Carlson Engineering

THRU: Patricia Gehlen
City of Tucson, Development Services Department

FROM: Dickie Fernández, E.I.T.
Pima County Development Services Department
Development Review Division (Wastewater)

SUBJECT: Eastside Industrial Center, Lots 1-12
Tentative Plat – 2nd Submittal
S06-093

The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


As previously requested on May 24, 3006, please provide a letter from PCWWM Planning Services, written within the past 90 days, stating that treatment and conveyance system capacity for this project is available. A capacity request form may be found at http://www.pima.gov/wwm/forms/docs/CapResponseRequest.pdf.

SHEET 3. As previously requested on May 24, 3006, please show the recording information for any existing public sewer easements. Please make sure that if such easements do exist, they are properly demarcated. This information shall include the recording information.

We will require a revised set of drawings and a response letter addressing each comment. Additional comments may be made during the review of these documents.

The next submittal of this project will be the 2nd submittal. A check for the review fee of this submittal in the amount of $39.00 made out to PIMA COUNTY TREASURER must accompany the revised set of bluelines and response letter.

For any questions regarding the fee schedule, please go to http://www.pimaxpress.com/SubDivision/Documents/Fees.PDF where you may find the appropriate wastewater review fees at the bottom of page 1. If the number of sheets changes, please adjust the review fee accordingly.


If you have any questions regarding the above mentioned comments, please contact me. Sincerely,





Dickie Fernández, E.I.T.
Telephone: (520) 740-6947

Copy: Project
07/20/2006 PETER MCLAUGHLIN ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

TO: Development Services Center
Plans Coordination Office

FROM: Peter McLaughlin
Senior Planner

FOR: David Rivera
Principal Planner

PROJECT:
S06-093
Eastside Industrial Center
Tentative Plat/Development Plan

TRANSMITTAL: July 20, 2006
DUE DATE: July 31, 2006

The Zoning Review Section at Development Services verifies that the tentative plat meets the requirements of the Land Use Code, subject to the following changes/requirements. However, should there be any changes requested by other CDRC members, the approval is void, and we request copies of the corrected tentative plat to verify that those changes do not affect any zoning requirements.

1. The title block in the lower right hand corner of each sheet of the plat must include a statement that this project is a condominium development. Revise.
DS 2-03.2.1.G.2

2. As acknowledged in the response comments a copy of proposed CC&R's must be provided to the Zoning Review Section for review and approval prior to approval of the final plat. The CC&R's must meet the criteria of DS 2-03.6.6.
DS 2-03.7.1.E

If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608.
07/26/2006 LAITH ALSHAMI ENGINEERING REVIEW Approved Laith Alshami, Engineering and Floodplain Review, 07/26/2006

TO: Patricia Gehlen FROM: Laith Alshami, P.E.
CDRC Engineering


SUBJECT: Eastside Industrial Center
S06-093, T14S, R15E, SECTION 21

RECEIVED: Tentative Plat and Drainage Report on June 30, 2006

The subject project has been reviewed. The Drainage Report is acceptable for Tentative Plat purposes and it is hereby approved. Additional drainage related information might be required with the Grading Plan. The Tentative Plat is recommended for approval pertaining to Engineering and Floodplain.
07/28/2006 KAY MARKS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S06-093 EASTSIDE INDUSTRIAL CENTER/TENTATIVE PLAT
DATE: 7/27/06



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.



***The Pima County Addressing Section can use digital CAD drawing files when
submitted with your final plat Mylar. These CAD files can be submitted through the Pima
County Subdivision Coordinator. The digital CAD drawing files expedite the addressing
and permitting processes when we are able to insert this digital data into the County’s
Geographic Information System. Your support is greatly appreciated.***




ES
08/04/2006 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

August 4, 2006

Greg Carlson
Greg Carlson Engineering, LLC
1521 East Broadway
Tucson, AZ 85719

Subject: S06-093 Eastside Industrial Center TentativePlat

Dear Greg:

Your submittal of June 30, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLUELINES MUST BE FOLDED

3 Copies Revised Tentative Plat (Landscape, Wastewater, DSD)

2 Copies Revised Landscape Plans (Landscape, DSD),








Should you have any questions, please call me at 791-5608 ext. 1179.

Sincerely,


Patricia Y. Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/
Via fax: 624-4197
08/04/2006 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Approved DEPARTMENT OF URBAN PLANNING & DESIGN

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

S06-093 Eastside Industrial Center 08/04/06

(XXXX) Tentative Plat
() Development Plan
() Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
() Other

CROSS REFERENCE: C9-85-95

NEIGHBORHOOD PLAN: General Plan

GATEWAY/SCENIC ROUTE:

COMMENTS DUE BY: 07/31/06

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

() No Annexation or Rezoning Conditions, Not an RCP - No Comment
() Proposal Complies with Annexation or Rezoning Conditions
() RCP Proposal Complies With Plan Policies
() See Additional Comments Attached
(XXXX) No Additional Comments - Complies With Planning Comments Submitted on: 05/19/06
() Resubmittal Required:
() Tentative Plat
() Development Plan
() Landscape Plan
() Other