Plan Number: S06-089
Parcel: Unknown

Address:
2550 E RIVER RD

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - FINAL PLAT REVIEW

Plan Number - S06-089
Review Name: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/09/2006 MARILYN KALTHOFF START PLANS SUBMITTED Completed
06/20/2006 FRODRIG2 PIMA COUNTY WASTEWATER Approved June 20,2006

To: Doug Schneider, Rick Engineering

Thru: Patricia Gehlen, CDRC Project Manager
City of Tucson Development Services Department

____________________________________
From: Michael J. Harrington (520-740-6579), representing the Pima County
Departments of Wastewater Management and Environmental Quality

Subject: Villas at Hacienda Del Sol (The)
Units 1-218, Units G1 thru G29
Limited Common Elements C1 thru C205 and Common Element
Final Plat - 2nd Submittal
S06-089

The proposed final plat for the above-referenced project has been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.



The Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the final plat as submitted.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.


If you have any questions regarding the above mentioned comments, please contact me at the telephone number shown under my signature on the first page of this letter

CC: Project File
06/29/2006 PATRICIA GILBERT ENGINEERING REVIEW Denied TO: Patricia Gehlen; CDRC Coordinator DATE: June 29, 2006

SUBJECT: Engineering review of the Villas at Hacienda Del Sol Final Plat. The activity number is S06-089.

SUMMARY: The Final Plat and CC&Rs were received by Engineering on June 9th, 2006. Engineering has reviewed the received items and does not recommend approval of the Final Plat or the Assurances.

RESUBMITTAL REQUIRED: FINAL PLAT, ASSURANCES, BOUNDARY CLOSURE CALCS,

SUBMITTAL REQUIRED: original CC&Rs

CC&Rs are approvable. Once the mylars for the final plat please submit the signed original CC&Rs.

The next submittal must address the following items:

GENERAL COMMENTS

1. The final plat cannot be scheduled for Mayor and Council consideration until the financial assurances are approved. The complete assurances package must include a copy of the original trust, the original amendment to trust with exhibit A, the original agreement to construct with exhibit B, a copy of the warranty deed, a current title report and a location map on an 8 ½ x 11 sheet. DS 2-03.7.1.G

The Final Plat will not be approved until the Assurance Package is approved.

ASSURANCE COMMENTS

1. The first page of the "Amendment to Trust" and the "Agreement to Construct" must be revised. The Subdivision Case number, S01-045 is not correct, the Subdivision Case number for this project is S06-089. Revise both documents to show the correct Subdivision Case number, S06-045 at the top of each document.

2. The title in section one, first page of the "Amendment to Trust" and section A of the "Agreement to Construct" is incorrect. Provide the verbiage, "Units 1 Thru 218, Units G1 Thru G29, limited Common Elements C1 Thru C205 and Common Element," after the verbiage, "The Villas at Hacienda Del Sol." Revise both documents as requested.

3. Exhibit A "legal description" In the "Amendment to Construct" appears to not be correct. Typically Exhibit A the reads for example something like; lots 1-100 of Saguaro Estates, and CA's of Saguaro Estates … in Book ___ page ___ (blank). It is not clear why a legal description with bearings and distances has been provided. Please clarify in the response letter or submit a revised Exhibit A.

4. It is not clear why an "Exhibit B" was attached to the "Amendment to Trust." Typically "Exhibit B" is attached to "Amendment to Construct." This office will change the documents appropriately. No revision required.

5. Replace the verbiage found in Exhibit B, number 9, with the following verbiage, "If any offsets against impact fees have been requested, all improvements that are the subject of the requested offsets shall be completed and accepted by the City prior to the final release of assurances. Assurances may be partially released prior to the completion of all improvements provided the releases are proportional to the level of completion of improvements."

6. A full explanation of the easements found in the title report must be shown on the final plat. There are several easements listed in the title report that are not shown on the final plat. Revise the plat to show all easements listed on title report or explain the discrepancies in the response letter

7. Submit a copy of an 8.5x11 index map - they are used for final plat assurances processing, tracking lot releases and construction progress. Provide a (8½ by 11) copy of a location map.


FINAL PLAT COMMENT

1. It has been brought to this office attention that the plat activity number, S01-045, pertains to a development, Hacienda Del Sol Office Complex just north of The Villas at Hacienda Del Sol. Is this project a resubdivision of S1-045, Hacienda Del Sol Office Complex? If this project is a resubdivision of a previously recorded subdivision, indicate the appropriate verbiage in the title block. If this project is not a resubdivision, remove the S01-045 activity number from each page of the plat.

2. It has also been brought to the attention of this office a submittal of a revised grading plan has been requested by the City of Tucson Engineering Inspector. Be advised any changes on the revised grading plan that affect the final plat must be made on the final plat. For example if the square footage any of the common elements have changed this would effect the final plat. Revise if necessary and it is recommended to submit the revised grading plan to Development Services Permit Counter as soon as possible.
07/14/2006 KAY MARKS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S06-089 THE VILLAS AT HACIENDA DEL SOL/REVISED FINAL PLAT
DATE: July 14, 2006



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.



***The Pima County Addressing Section can use digital CAD drawing files when
submitted with your final plat Mylar. These CAD files can be submitted through the Pima
County Subdivision Coordinator. The digital CAD drawing files expedite the addressing
and permitting processes when we are able to insert this digital data into the County’s
Geographic Information System. Your support is greatly appreciated.***
07/18/2006 HEATHER THRALL ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office

FROM: Heather Thrall
Senior Planner

PROJECT: S06-089
The Villas At Hacienda del Sol, condominiums conversion
Final Plat

TRANSMITTAL DATE: July 18, 2006

DUE DATE: July 18, 2006

COMMENTS:

1. Section 4.1.7.1, LUC, permits a maximum of one year from the date of application to obtain approval of a final plat. If, at the end of that time, the final plat has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this final plat is April 19, 2007.

2. The zoning comments issued June 4, 2006 (as follows) were not addressed. Resubmit a revised final plat and a response letter indicated how zoning comments were addressed.

3. Label the location map with both Allen/Tucson streets.

4. Clarify if building G29 will be assigned a building number and label.

5. Common elements should be delineated or enclosed with solid line and labeled separately as "A" landscape, "B" vehicular. Title block should also show these changes.

6. Show and label 1' no vehicular access easements where applicable.

7. The title sheet of the CCR's should include unit numbers, limited common elements and common area designations.

8. Cubic volumes should be listed for each unit on sheet 7 of 7.

9. If you have questions, contact me at Heather.Thrall@tucsonaz.gov or 791-4541x1156.

C:\planning\cdrc\finalplat\S06-089 villas at hacienda del sol 2.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat/CC&R's.
07/20/2006 FRODRIG2 COT NON-DSD REAL ESTATE Approved S06-089 The Villas at Hacienda del Sol: Resubmittal - CDRC - Final Plat P - No comment.
07/21/2006 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

July 21, 2006

Doug Schneider
Rick Engineering Company, Inc.
1745 East River Road, Suite 101
Tucson, AZ 85718

Subject: S06-089 - The Villas at Hacienda Del Sol Condominium Final Plat

Dear Doug:

Your submittal of July 21, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLUELINES MUST BE FOLDED

3 Copies Revised Final Plat (Zoning, Engineering, DSD)

3 Copies Revised CC&R's (Zoning, Engineering, DSD),

2 Copies Boundary Closure Calculations (Engineering, DSD)









Should you have any questions, please call me at 791-5608 ext. 1179.

Sincerely,


Patricia Y. Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/
Via fax: 322-6956