Plan Number: S06-086
Parcel: Unknown

Address:
1745 E GLENN ST

Review Status: Completed

Review Details: FINAL PLAT REVIEW

Plan Number - S06-086
Review Name: FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/17/2006 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
04/25/2006 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Approved SUBJECT: COPPER STAR CONDOMINIUMS
S06-086



Tucson Electric Power Company has reviewed and approved the plat
submitted for review April 18, 2006.



Please call me at (520) 917-8745, should you have any questions.



Liza Castillo
Right of Way Agent
Land Management
Tucson Electric Power Co.
(520) 917-8745
lcastillo@tep.com
04/28/2006 FRODRIG2 PIMA COUNTY WASTEWATER Approv-Cond April 27, 2006

To: Jack Buchanan, The WLB Group

Thru: Patricia Gehlen, CDRC Project Manager
City of Tucson Development Services Department

____________________________________
From: Michael Harrington (520-740-6579), representing the Pima County
Departments of Wastewater Management and Environmental Quality

Subject: Copper Star Condominium
Units: 101-143 and 201-243
Limited Common Elements and Common Element
Final Plat - 1st Submittal
S06-086

The proposed final plat for the above-referenced project has been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.



This project will be tributary to the Roger Road Wastewater Treatment Facility via the South Rillito - West (South Line) Interceptor. Per written guidance provided by the PCWMD Development Services Section, sufficient conveyance and treatment capacity exists in the downstream public sewerage system for this project, and a formal capacity response letter from the PCWMD will not be required. The sewers are existing and private.

All Sheets: Add the subdivision case number, S06-086, to the title block of each sheet. This number should be shown larger or bolder than any cross-reference numbers. No wastewater review fees will be charged for sheets where this is the only required revision.

Subject to the above, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the final plat. The required revision(s) may be shown on the Mylars.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.


If you have any questions regarding the above mentioned comments, please contact me at the telephone number shown under my signature on the first page of this letter

CC: Project File
05/15/2006 JOSE ORTIZ ENGINEERING REVIEW Denied DATE: May 15, 2006

TO: Patricia Gehlen, CDRC Manager

FROM: Jose E. Ortiz, Civil Engineering

SUBJECT: Engineering review of the Copper Star Condo Conversion. The activity # S06-086.

RESUBMITTAL REQUIRED: Final Plat

Engineering has reviewed the received items and does not recommend approval of the Final Plat.


1. The words "Book ____ Page ____" get cut off on a number of sheets. Please correct.

2. Dedication Language. Use one (1) of the following four (4) statements as may be appropriate for the plat. Sec. 2-03.6.3.B.2.c may be used in subdivisions with private elements. Sec. 2-03.6.3.B.2.d may be used where electrical facilities are not specifically located in common areas. DS 2-03.6.3.B.2

q "(I/We) hereby dedicate and convey to the Public forever all rights-of-way as shown hereon, including all streets, roads, parks, easements, and drainageways." DS 2-03.6.3.B.2.a

q "(I/We) hereby grant to the Public and all utility companies all easements as shown hereon for the purposes of access for installation and maintenance of public sewers and utilities and other uses as designated by this plat." DS 2-03.6.3.B.2.b

q "Private streets, drainageways, and common areas, as shown hereon, are reserved for the private use and convenience of all owners of property within this subdivision and are granted as easements to the Public and all utility companies for the purposes of access, installation, and maintenance of utilities, drainage, and public sewers. Title to the land of all private streets, drainageways, and common areas shall be vested in an association of individual lot owners as established by Covenants, Conditions, and Restrictions recorded in Docket ____ at Pages ____ through ____ in the office of the Pima County Recorder. The association will accept responsibility for control, maintenance, and liability for the private streets, drainageways, private sewers, and common areas within this subdivision." DS 2-03.6.3.B.2.c

q "Private streets, drainageways, and common areas shown on this plat are reserved for the private use and convenience of all owners of property within this subdivision, and easements are granted to the Public and all utility companies together with access for the installation, maintenance, and improvements of aboveground and underground utilities, public sewers, and drainage. Title to the land of all private streets, drainageways, and common areas will be vested in an association of individual lot owners as established by Covenants, Conditions, and Restrictions recorded in Docket ____ at Pages ____ through ____ in the office of the Pima County Recorder. The association will accept responsibility for control, maintenance, and liability for the private streets, drainageways, private sewers, and common areas within this subdivision." DS 2-03.6.3.B.2.d



3. Show no-vehicular access easements where applicable. DS 2-03.6.4.H

4. If applicable, show detention/retention areas in a surveyable and readily retraceable manner. DS 2-03.6.4.I

5. If applicable, indicate all with accurate dimensions and bearings. DS 2-03.6.5.B

6. Sheet 3: address the following comments (These comments are typical for sheets 3-14)

· Provide a common tie down point to the building to link with the dimensions provided on sheet 2.
· Provide a bearing and distance from the LCE patio corner (tie-downed on sheet 2) to a corner of the unit.
· Provide a dimension from the exterior wall to the interior wall of each unit.
· Provide a distance between units vertically. From the ceiling of the lower unit to the FFE of the upper unit.
· Provide an FFE on the first floor of each building.
· Complete the "UNIT DESCRIPTION TABLE" and insert interior volumes.

7. Sheet 4: In addition to comment # 6, provide dimensions between each units.

8. Sheet 5: See comment # 6.

9. Sheet 6: See comment # 6 & 7. The dedication on sheet 1 indicates that the office is part of the common element; therefore provide unit boundaries between the office and the condo unit.

10. Sheet 7: See comment # 6.

11. Sheet 8: See comment # 6 & 7.

12. Sheet 9: See comment # 6 & 7.

13. Sheet 10: See comment # 6 & 7.

14. Sheet 11: See comment # 6. The north arrow appears to be pointing in the wrong direction, if needed please correct.

15. Sheet 12: See comment # 6. The north arrow appears to be pointing in the wrong direction, if needed please correct.

16. Sheet 13: See comment # 6 & 7.

17. Sheet 14: See comment # 6.

18. Schedule B of the title report indicates that the following easements exist; docket #'s 1648, 7729, 7757, 7800, and 8977. The only docket # provided is 7729, do the other easements effect this site? If so please show these easements in a surveyable manner with Docket information.



If you have any questions, I can be reached at 791-5640 ext. 1191 or jose.ortiz@tucsonaz.gov

Jose E. Ortiz, PE
Civil Engineer
05/16/2006 ED ABRIGO PIMA COUNTY ASSESSOR Approved Office of the Pima County Assessor
115 N. Church Ave.
Tucson, Arizona 85701

BILL STAPLES
ASSESSOR




TO: CDRC Office
Subdivision Review
City of Tucson (FAX# 791-5559)

FROM: Gary Ault, Mapping Supervisor
Pima County Assessor’s Office
Mapping Department

DATE: May 15, 2006


RE: Assessor’s Review and Comments Regarding Final Plat
S06-086 Copper Star Condominiums T141405 (113-07)

* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

X Plat meets Assessor’s Office requirements.
_______ Plat does not meet Assessor’s Office requirements.


COMMENTS: Thank you for your submittal. Please make the following additions before recording this plat.
Add the bearing for the north line of the subdivision and add the bearings for the tie lines from the boundary to the buildings.
Unless the drive and the subdivision grounds are two separate elements, please dash the lines delineating the private drive. Otherwise, it looks like two parcels and would require two parcel codes.
If there are any questions, please contact Susan King at 740-4391.

NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.






Susan King
05/16/2006 KAY MARKS PIMA COUNTY ADDRESSING Approv-Cond 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S06-086 COPPER STAR CONDOMINIUMS/FINAL PLAT
DATE: 5/15/06



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.

NOTE: Approved with the following condition:

1.) Complete the spelling of Avenue for Cherry and Campbell (Sheet 2) on mylar.



***The Pima County Addressing Section can use digital CAD drawing files when
submitted with your final plat Mylar. These CAD files can be submitted through the Pima
County Subdivision Coordinator. The digital CAD drawing files expedite the addressing
and permitting processes when we are able to insert this digital data into the County’s
Geographic Information System. Your support is greatly appreciated.***





es
05/23/2006 FRODRIG2 COT NON-DSD REAL ESTATE Approved S06-086 Copper Star Condominiums: Final Plat Review. No Comments.
06/03/2006 PGEHLEN1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Passed
06/14/2006 HEATHER THRALL ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office

FROM: Heather Thrall
Senior Planner

PROJECT: S06-086
Copper Star Condominium conversion
1745 E. Glenn Street

TRANSMITTAL DATE: June 14, 2006

DUE DATE: May 15, 2006

COMMENTS:

1. Section 4.1.7.1, LUC, permits a maximum of one year from the date of application to obtain approval of a final plat. If, at the end of that time, the final plat has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this final plat is April 17, 2007.

2. This plat was reviewed for compliance with the Land Use Code (LUC) and Development Standards (DS). Specifically, the project was reviewed under requirements of final plat content listed in DS 2-03.6.0.

3. Per DS 2-03.6.1.B, please ensure the resubmittal has half-inch margins on all sides, excluding the left, to meet recordation standards.

4. Per DS 2-03.6.1.H.1, please list the elements of the common areas (separated common areas recommended A,B,C - see comments 8 and 9) - pool, recreation building, play area, parking area, office, etc. As for limited common elements, please clarify if stairways and covered parking areas are included in this category.

5. Per DS 2-03.6.1.K, list the case number "S06-086" near the title block.

6. Per DS 2-03.6.3.D, please revise the approval paragraph to include the word "Arizona," before hereby.

7. Per DS 2-03.6.3.D, to meet recording requirements, please revise the recording paragraph to match 2-03.6.3.D exactly as shown on page 22 of the platting process - final plat section. There are several extra words to be removed and some periods and commas needed.

8. General note 8 of the plat states the parking will not be assigned, however, page 16 of the CCRs state that the covered parking is reserved and will be allocated at time of unit sale. Please show assigned parking as a Limited Common Element, with a space number designation and measurements.

9. Page 22 of the CCRs states that the association has the right and easement of enjoyment in and to the common elements, subject to the provision that if the assessments are unpaid these rights are suspended. As the plat infers that parking is a common element, this provision must be either removed or modified to ensure that at no time vehicular (and obviously pedestrian and handicapped) access is prevented to a unit.

This is where the common elements may be more appropriately labeled individually as A, B, C, etc and what they contain. Be sure to change the title block appropriately if this is done.

10. It appears that 2 units and a public office for the condominiums will be located, as is currently for the apartments, in building 4. The plat does not clarify the square footage of the office and whether it is limited to the 1st floor. Please clarify.

11. The recreation building is not addressed in the plat, as to whether it is to become a common area, a condo conversion, etc. The square footage of the building should be provided in whatever element it will become with this project.

12. Provide a note on the plat (in general note of parking information is fine)and in the CCRs that each unit shall be provided a minimum of one parking space. (The site is legal nonconforming for the amount of parking spaces provided on the last approved site plan for the development, and thus with current code not being able to be met for the parking required for each unit, one space minimum shall be provided for each unit.)

13. Provide an affidavit certifying how LUC 4.1.9.1 and 4.1.9.2 will be met.

14. Provide cubic volume calculations for each condo unit.

15. Depending upon the responses provided, further review comments may be forthcoming. Should you have any questions on this review, please contact me via email at Heather.Thrall@tucsonaz.gov or at 791-4541x1156.



If you have any questions about this transmittal, please call (520) 791-5608.


C:\planning\cdrc\finalplat\S06-086 copper star.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat, revised CC&R's and additional requested documents.
06/16/2006 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

June 16, 2006

Jack Buchanan
The WLB Group, Inc.
4444 East Broadway Blvd.
Tucson, AZ 85711

Subject: S06-086 - Copper Star Condominiums Final Plat

Dear Jack:

Your submittal of April 18, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLUELINES MUST BE FOLDED

3 Copies Revised Final Plat (Zoning, Engineering, DSD)

3 Copies Revised CC&R's (Zoning, Engineering, DSD),

2 Copies Affidavit (Zoning, DSD)









Should you have any questions, please call me at 791-5608 ext. 1179.

Sincerely,


Patricia Y. Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/
Via fax: 881-7492