Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Plan Number - S06-076
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/06/2006 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 09/12/2006 | KAROL ARAGONEZ | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Karol Aragonez Planner PROJECT: S06-076 Grant Road Professional Plaza Tentative Plat Resubmittal TRANSMITTAL DATE: September 12, 2006 DUE DATE: October 4, 2006 COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. Previous Comment: Once approved, add the W.A.S.H. overlay zone case number, date of approval, what was approved, and any conditions imposed as a general note and reference the overlay zone case number in the lower right hand corner near the title block. City Code Sec. 23A-51.4 2. The boundary between common areas "A" and "C" cannot be determined from the drawings. Please enclose each common area with a heavy solid line that will help distinguish the common area from each other clearly on sheet 2 of 3. Dimension each of the common areas on the plat. DS 2-03.2.4.C If you have any questions about this transmittal, please call Karol Aragonez, (520) 791-5550. KAA S:\zoning review\karol\planning\cdrc\tentativeplat\S06-076tpr.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised tentative plat. |
| 09/27/2006 | MARILYN KALTHOFF | PIMA COUNTY | WASTEWATER | Denied | September 26, 2006 TO: Dave Martin Kimley-Horn and Associates, Inc. THRU: Patricia Gehlen City of Tucson, Development Services Department FROM: R S Engineering (Contract Reviewer) Chandubhai Patel, P.E. Pima County Development Services Department Development Review Division (Wastewater) SUBJECT: Grant Road Professional Plaza Development Plan/ Tentative Plat-3rd Submittal, S06-076 The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. 1. It is recommended that the designer familiarize himself with the Arizona Department of Environmental Quality's Engineering Bulletin #11. Specifically, Chapter IV, Section D, "Design Details". This design appears to have cleanouts located in places that require manhole structures. Please review the requirements of Bulletin #11 (page IV-9) and insure that manholes are provided at all locations of the 8" sewer line that have a change in grade, direction and/or alignment, at intersections, etc. The next submittal of this project will be the 4th submittal. A check for the review fee of this submittal in the amount of $39.00 per sheet, made out to PIMA COUNTY TREASURER must accompany the revised set of bluelines and response letter. For any questions regarding the fee schedule, please go to http://www.pimaxpress.com/SubDivision/Documents/Fees.PDF where you may find the appropriate wastewater review fees at the bottom of page 1. If the number of sheets changes, please adjust the review fee accordingly. If you have any questions regarding the above comments, please do not hesitate to contact me. Sincerely, Chandubhai Patel, P.E. Telephone: (520) 740-6563 Copy: Project File |
| 09/27/2006 | JOE LINVILLE | LANDSCAPE | REVIEW | Approv-Cond | The Landscape Section conditionally approves the project subject to compliance with the following conditions and approval of the WASH Case. Note the case number and date of approval on all plans. 1) Revise tree planters located in vehicle overhang areas such that the trees are planted at the edge of adjoining spaces, rather than centered in the front of the parking space. Revise both the landscape and development plans. DS 2-06.3.3.E 2) Slopes for retention/detention basins are required to have slopes no steeper than 4:1 where depths exceed three feet, 3:1 for unprotected side slopes and 2: 1 for protected slopes for depths less than three feet. Revise basin slopes. DS 10-01.4 3) A covenant is requied to allow the use an existing screen on an adjacent property to meet screening requirements. When executed, provide a copy of the recorded covenant for use the existing screen(s) on adjacent property. Certificates of Occupancy will not be issued until the wall requirements are met. All walls must be tall enough to provide the code required screening. DS 2-03.2.1.A.15 4) Revise the landscape plans to indicate the preservation of existing vegetation along the Rose Hill Wash and to identify the species proposed between the parking lot and the trail easement. |
| 09/27/2006 | ROGER HOWLETT | COT NON-DSD | COMMUNITY PLANNING | Approved | DEPARTMENT OF URBAN PLANNING & DESIGN Regarding SUBJECT: Community Design Review Committee Application CASE NUMBER: CASE NAME: DATE SENT S06-076 Grant Road Professional Plaza 09/26/06 ( ) Tentative Plat (XXXX) Development Plan (XXXX) Landscape Plan ( ) Revised Plan/Plat ( ) Board of Adjustment ( ) Other CROSS REFERENCE: C9-05-28 NEIGHBORHOOD PLAN: Arcadia-Alamo GATEWAY/SCENIC ROUTE: COMMENTS DUE BY: 10/04/06 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: ( ) No Annexation or Rezoning Conditions, Not an RCP - No Comment ( ) Proposal Complies with Annexation or Rezoning Conditions ( ) RCP Proposal Complies With Plan Policies ( ) See Additional Comments Attached (XXXX) No Additional Comments - Complies With Planning Comments Submitted on: 07/1/06 ( ) Resubmittal Required: ( ) Tentative Plat ( ) Development Plan ( ) Landscape Plan ( ) Other REVIEWER: DCE 791-4505 DATE: 09/26/06 |
| 09/29/2006 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES September 29, 2006 Dave Martin Kimley-Horn and Associates, Inc 1860 East River Road, Suite 100 Tucson, Arizona 85718 Subject: S06-076 Grant Road Professional PlazaTentative Plat Dear Dave: The above referenced plan has been CONDITIONALLY APPROVED by the Community Design Review Committee, subject to the revisions required on the mylars. Please submit the following documents for sign-off: 1 Reproducible Océ or Photo Mylar of the Plat, Landscape Plan and NPPO. Additional blackline copies will be made from the complete set and distributed to various review agencies for their files. These copies will be ordered from the City's contracted print company and billed to you unless you already have an account at another printing company. Please let us know which printing company you would prefer to use and list them on your attached transmittal form when submitting your mylars to the CDRC office for sign-off approval. Your printing company will deliver the mylar and three (3) blackline copies to your office. If you are out of town you will need to contact the printing company for pick up or mailing arrangement options. PRIOR TO SUBMITTAL OF THE MYLARS TO THE CDRC OFFICE, THEY MUST BE REVIEWED AND APPROVED BY PIMA COUNTY WASTEWATER. A GENERAL NOTE MUST BE ADDED TO THE TENTATIVE PLAT THAT LISTS THE DSMR CASE NUMBER, DATE OF APPROVAL, MODIFICATIONS GRANTED AND CONDITIONSOF APPROVAL. THE CASE NUMBER MUST ALSO BE ADDED TO EACH SHEET OF THE PLAT, LANDSCAPE, AND NPPO PLANS, IN THE LOWER RIGHT HAND CORNER NEXT TO THE TITLE BLOCK. Should you have any questions, please call me at 791-5608 extension 1179. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 615-9292 tp-approved |
| 09/29/2006 | LOREN MAKUS | ENGINEERING | REVIEW | Approv-Cond | DATE: September 29, 2006 To: Patricia Gehlen CDRC/Zoning Manager FROM: Loren Makus, EIT Engineering Division SUBJECT: Grant Road Professional Plaza Development Plan/Tentative Plat S06-076 (Third Review) T14S, R14E, Section 19 RESUBMITTAL REQUIRED: None The Engineering Division has reviewed the Development Plan and Drainage Report for Grant Road Professional Plaza and recommends approval at this time subject to the following conditions: 1. The Development Plan/Tentative Plat must show maneuverability for the appropriate design vehicle for access to each loading zone and for the solid waste enclosures. 2. The Development Plan/Tentative Plat must clearly indicate where curb access ramps will be provided throughout the project area. If curb access ramps are not provided near each handicapped parking space, indicate how access will be provided. If the sidewalk is flush with the adjacent pavement, additional truncated domes may be required. 3. The Development Plan/Tentative Plat must show sufficient landings for all curb access ramps. If you have any questions, I can be reached at 791-5550 x1161 or loren.makus@tucsonaz.gov. Loren Makus, EIT Senior Engineering Associate |