Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: S06-072
Parcel: Unknown

Address: Unknown

Review Status: Completed

Review Details: TENTATIVE PLAT REVIEW

Plan Number - S06-072
Review Name: TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/28/2006 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
04/11/2006 JIM EGAN COT NON-DSD FIRE Approved For future reference....
Tucson Fire Code Section 10.302, 10.207, etc. has been replaced by the IFC 2003, and C.O.T. modifications.
04/12/2006 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Approved SUBJECT: NCR OF TUCSON
S06-072


Tucson Electric Power Company has reviewed and approved the tentative
and final plat submitted March 28, 2006. It appears that there are no
conflicts with the existing facilities within the boundaries of this
proposed development.

Enclosed is a copy of a TEP facilities map showing the approximate
location of the existing facilities.

In order to apply for electric service, call the New Construction
Department at (520) 918-8300. Submit a final set of plans including
approved site, offsite and electrical load plans. Include a CD with the
AutoCAD version of the plans. If easements are required, they will be
secured by separate instrument. Your final plans should be sent to:

Tucson Electric Power Company
Attn: Ms. Mary Boice
New Business Project Manager
P. O. Box 711 (DB-101)
Tucson, AZ 85702
520-917-8732

Please call the area Designer Mike Kaiser at (520) 918-8244, should you
have any questions.


Sincerely,



Kathy Clark
Scheduling Coordinator
Design/Build
kc
Enclosures
cc: P. Gehlen, City of Tucson
M. Kaiser, Tucson Electric Power Company

Kathy Clark
Scheduling Coordinator
Design/Build
520-918-8271
kclark@tep.com
04/12/2006 FRODRIG2 PIMA COUNTY WASTEWATER Denied April 11, 2006

TO: Thomas Sayler-Brown
Sayler-Brown Bolduc Lara Architects, LLC

THRU: Patricia Gehlen
City of Tucson, Development Services Department

FROM: Dickie Fernández, E.I.T.
Pima County Development Services Department
Development Review Division (Wastewater)

SUBJECT: NCR of Tucson, Lots 1-3 & Block A
Development Plan – 1st Submittal
S06-072


The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


Be aware that the final plat for this project will not be approved until the subject tentative plat/development plan is approved.

Provide a letter from PCWWM Planning Services, written within the past 90 days, stating that treatment and conveyance system capacity for this project is available. A capacity request form may be found at http://www.pima.gov/wwm/forms/docs/CapResponseRequest.pdf.

ALL SHEETS. Add the project number, S06-072, to the title block of each sheet. This number should be shown larger or bolder than any cross-reference numbers.

SHEET DP1. Place the project number S04-038 in the box along with the rest of the reference project numbers.

Based on the evaluation of the proposed sewer design, this project qualifies for Standard sewer connection fee rates.

SHEET DP1. Divide General Note 9 into three different general notes.

SHEET DP1. Revise General Note 16 as follows and fill in the blanks appropriately.

THIS PROJECT HAS ____ PROPOSED AND ____ EXISTING WASTEWATER FIXTURE UNIT EQUIVALENTS, PER TABLE 13.20.045(E)(1) IN PIMA COUNTY CODE 13.20.045(E).

SHEET DP2. Revise the sewer layout so that it matches exactly the symbols within the legend.

SHEET DP2. Revise the sewer design so that no more than 100 feet separate any proposed cleanout from a manhole or another proposed cleanout.

We will require a revised set of drawings and a response letter addressing each comment. Additional comments may be made during the review of these documents.

The next submittal of this project will be the 2nd submittal. A check for the review fee of this submittal in the amount of $100.00 made out to PIMA COUNTY TREASURER must accompany the revised set of bluelines and response letter.

For any questions regarding the fee schedule, please go to http://www.pimaxpress.com/SubDivision/Documents/Fees.PDF where you may find the appropriate wastewater review fees at the bottom of page 1. If the number of sheets changes, please adjust the review fee accordingly.


If you have any questions regarding the above mentioned comments, please contact me. Sincerely,





Dickie Fernández, E.I.T.
Telephone: (520) 740-6947

Copy: Project
04/19/2006 PETER MCLAUGHLIN ZONING REVIEW Denied 1. An applicant has one (1) year from the date of application to obtain approval of a tentative plat that complies with zoning and other development requirements in effect at the time of application. This tentative plat must be approved on or before March 27, 2007.

2. Fill in the S06-072 number near the title block in the lower right hand corner of all sheets of the plat, landscape and NPPO plans.
DS 2-03.2.2.B.1

3. All pedestrian sidewalks and ramps must meet new ADA requirements by utilizing truncated domes rather than the scored concrete tactile warning devices shown in access ramp details #3 and #4 on sheet DP2. Revise details to show the truncated domes indicating all sidewalk grade changes and pedestrian crosswalks. Also, add a specific statement to general note 24 indicating that truncated domes shall be used at all crosswalks, access ramps and as otherwise required.
ANS

4. Revise "12th Street" in the location map on sheet DP1 to read "12 Avenue".
DS 2-05.2.1.D.2

5. The square footage of site area for Lot #3 as stated in the calculations (167,937 square feet) does not equal 3.90 acres and is not consistent with the square footage given in general note 5 (170,054 square feet) for Lot #3. It is also not consistent with the square footage given on the final plat (170,065 square feet). Revise to be accurate and consistent. Revise percent coverage calculation if necessary based on any changes in square footages calculated.
DS 2-03.2.4.B

6. For measuring building heights the vertical distance of a building is measured from design grade elevation rather than finished floor elevation, at any point within the building footprint to the middle (between eave and ridge) of the highest gable of a pitched roof. Revise all elevation drawings on sheet DP4 to show compliance with maximum height restriction of 25 feet based on design grade elevation. Add dimensions to the elevation drawings showing midpoint height maximum, ridgeline height maximum and eave height maximum above design grade as required.
LUC 3.2.7.2

7. Label class 1 and class 2 bicycle parking clearly on the plan or provide a legend symbol. Bicycle parking must be evenly distributed and conveniently located to main building entrances. Where not directly visible and obvious from the public right-of-way and entrances to the site, project entry and directional signs will be provided to direct bicyclists to the bicycle parking areas.
DS 2-03.2.4.Q
DS 2-09.4
DS 2-09.5
04/19/2006 PETER MCLAUGHLIN LANDSCAPE REVIEW Approv-Cond Fill in the S06-072 number near the title block in the lower right hand corner of all sheets of the plat, landscape and NPPO plans.
DS 2-03.2.2.B.1
04/21/2006 KAY MARKS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S06-072 NCR OF TUCSON/TENTATIVE PLAT
DATE: 4/21/06



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.


***The Pima County Addressing Section can use digital CAD drawing files when
submitted with your final plat Mylar. These CAD files can be submitted through the Pima
County Subdivision Coordinator. The digital CAD drawing files expedite the addressing
and permitting processes when we are able to insert this digital data into the County’s
Geographic Information System. Your support is greatly appreciated.***





ES
04/25/2006 ELIZABETH EBERBACH ENGINEERING REVIEW Approved TO: Patricia Gehlen; CDRC Coordinator
SUBJECT: NCR Tentative Plat Submittal Engineering Review
REVIEWER: Elizabeth Eberbach
ACTIVITY NUMBER: S06-072

SUMMARY: The Tentative Plat package was received by Engineering. Development Services Department Engineering Division has done a review of the received items and recommends approval. Call me at 791-5550, extension 2204 if you would like to set up a meeting or if you have any questions.

Elizabeth Eberbach, PE, CPM
Civil Engineer
Engineering Division
Development Services
05/01/2006 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Denied DEPARTMENT OF URBAN PLANNING & DESIGN

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

S06-072 NCR of Tucson 04/27/06

(X) Tentative Plat/Development Plan
() Development Plan
() Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
() Other

CROSS REFERENCE: C9-03-15

NEIGHBORHOOD PLAN: General Plan

GATEWAY/SCENIC ROUTE: NO

COMMENTS DUE BY: April 25, 2006

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

() No Annexation or Rezoning Conditions, Not an RCP - No Comment
() Proposal Complies with Annexation or Rezoning Conditions
() RCP Proposal Complies With Plan Policies
(X) See Additional Comments Attached
() No Additional Comments - Complies With Planning Comments Submitted on:
(X) Resubmittal Required:
(X) Tentative Plat/Development Plan
() Development Plan
(X) Landscape Plan
() Other

REVIEWER: msp 791-4505 DATE: April 25, 2006

Department of Planning and Design Comments
S06-072-NCR of Tucson Tentative Plat
April 25, 2006

The development site is subject to rezoning case C9-03-15, and any reference to rezoning conditions make on this review are made in reference to C9-03-15. Staff offers the following comments:

Please revise tentative plat/development plan to be in compliance with rezoning condition # 1, which requires the development plan to be in substantial compliance with development plan dated June 13, 2003. Development plan, dated June 13, 2003, states within lot 3, just south of the building foot print that “this project is self sufficient apartment living and is not an adult care facility.” Please add this information, per “verbatim” on tentative plat/development plan. Add this information in bold letters, locate information on sheet 2 of 4, and add it to the bold letter that identifies the existing zone as R-1 and proposed zone as R-2.

Please revise tentative plat/development plan to be in compliance with rezoning condition # 2. Revise sheet 2 of 4, as a revised key note # 6 to ensure that a cross access easement has been recorded to provide cross-access to Irvington Road, between lots 1, 2, & 3, as recorded in Docket _____ and Page _____. Please provide the actual DKT. & PG. Numbers as part of Key Note # 6. In addition, please provide a hard copy of recorded document.

Please revise tentative plat/development plan; sheet 2 of 4, to complete the note that makes reference to a covenant stating “housing only to the elderly.” Please include the actual Docket and Page(s) numbers of this recorded covenant.

Please revise tentative plat/development plan to be in compliance with rezoning condition # 6, which requires that 5% of the residential units within the apartment complex shall be fully ADA compliant and that 2% of the residential units shall be designed for hearing/visually impaired tenants. Please revise DP3, sheet 3 of 4 to identify 4 residential units as fully ADA compliant units and to identify 2 residential units designed for hearing/visually impaired tenants.
05/08/2006 JCLARK3 ENV SVCS REVIEW Approved * No known landfill with in 1000 feet of this development.
* Commercial property for elderly apartments. Refuse agreement is for the dumpster to be serviced off the adjacent property to the south. Was assured by the Architect that an agreement was made between the two property owners.
05/08/2006 DALE KELCH COT NON-DSD TRAFFIC Approved Traffic Engineering recommends APPROVAL of this TP/DP

D. Dale Kelch, PE
Senior Engineering Associate
Traffic Engineering Division
(520)791-4259x305
(520)791-5526 (fax)
dale.kelch@tucsonaz.gov
05/11/2006 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

May 11, 2006

Thomas Saylor-Brown
Sayor-Brown Bolduc Lara Architects, LLC
1001 North Alvernon Way, Suite 105
Tucson, AZ 85711

Subject: S06-072 NCR of Tucson Tentative Plat

Dear Thomas:

Your submittal of March 28, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLUELINES MUST BE FOLDED

4 Copies Revised Tentative Plat (Community Planning, Wastewater, Zoning, DSD)

3 Copies Revised Landscape and Irrigation Plans (Community Planning, Zoning, DSD),









Should you have any questions, please call me at 791-5608 ext. 1179.

Sincerely,


Patricia Y. Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/
Via fax: 620-0535