Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Plan Number - S06-071
Review Name: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/14/2006 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 09/15/2006 | KAROL ARAGONEZ | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Karol Aragonez Planner PROJECT: S06-071 La Estancia de Tucson 419-674 Final Plat Resubmittal TRANSMITTAL DATE: September 14, 2006 DUE DATE: September 19, 2006 COMMENTS: The Zoning Review Section approves the final plat for this subdivision, subject to the following changes on the executed final plat. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised final plat to verify that those changes do not affect any zoning requirements. 1. Recordation of the previous plat must be preformed filling in Book and Page number blanks in title block. Note as to requirements for this process will be provided by the CDRC Manager at time of mylar submittal. If you have any questions about this transmittal, please call Karol Aragonez, (520) 791-5550. KAA S:\zoning review\karol\planning\cdrc\finalplat\S06-071fp.doc |
| 09/15/2006 | ROGER HOWLETT | COT NON-DSD | COMMUNITY PLANNING | Approved | SUBJECT: Community Design Review Committee Application Regarding CASE NUMBER: CASE NAME: DATE SENT S06-071(Final Plat) La Estancia De Tucson 09/15/06 (X) Final Plat () Development Plan () Landscape Plan () Revised Plan/Plat () Board of Adjustment () Other CROSS REFERENCE: La Estancia (PAD-7) & Tent.Plat- S05-098 (Tied to tent. Plat conditions and Phasing Notes 1 & 2) NEIGHBORHOOD PLAN: Rincon/Southeast Subregional Plan GATEWAY/SCENIC ROUTE: N/A COMMENTS DUE BY: September 19, 2006 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: () No Annexation or Rezoning Conditions, Not an RCP - No Comment () Proposal Complies with Annexation or Rezoning Conditions () RCP Proposal Complies With Plan Policies () See Additional Comments Attached (X) No Additional Comments - Complies With Planning Comments Submitted on: July 20, 2006 |
| 09/19/2006 | GLYNDA ROTHWELL | UTILITIES | TUCSON ELECTRIC POWER | Approved | SUBJECT: LA ESTANCIA DE TUCSON Lots 1-330, 331-410, 411-664 S05-098, S06-067, S06-071 The Final Plats for the subject projects will meet this Company's easement requirements. An additional easement will be added to sheet 4 of the mylar set for Lots 331-410 (S06-067), and TEP approves this. Please forward any resubmittals to this office. Electric service will be provided to this subdivision in accordance with the rules and regulations approved by the Arizona Corporation Commission. Please contact me at (520) 917-8745 if you have any questions. Liza Castillo Right of Way Agent Land Management Tucson Electric Power Co. (520) 917-8745 lcastillo@tep.com |
| 09/19/2006 | LAITH ALSHAMI | ENGINEERING | REVIEW | Denied | Laith Alshami, Engineering and Floodplain Review, 09/19/2006 TO: Patricia Gehlen FROM: Laith Alshami, P.E. CDRC Engineering SUBJECT: La Estancia De Tucson 411-664 S06-071, T15S, R15E, SECTION 19 RECEIVED: Final Plat and Assurances on September 14, 2006 Final Plat: The subject submittal has been reviewed. The Final Plat can not be approved until the following comments are satisfied: 1. The subject project Tentative Plat is approved and the Final Plat information matches the information on the approved Tentative Plat. 2. Complete the BOOK and PAGE information in the Title Block. Since the Title Block states that the subject development is a resubdivision of Block "D", then it is assumed that Block "D" subdivision was recorded. Fill in the recordation Book and Page numbers for Block "D" subdivision. 3. Although the basis of bearing is shown on the Plat, it does not appear that the subject development is tied into the basis of bearing. Verify compliance with the requirements of D.S. 2-03.6.5.A. 4. Provide the Bk. and Pg. numbers for the existing sewer easement south of lot 425 on Sheet 6/11. RESUBMITTAL REQUIRED: Revised Final Plat |
| 09/29/2006 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES September 29, 2006 Scott Altherr Castro Engineering Corp 3580 West Ina Road, #200 Tucson, Arizona 85741 Subject: S06-071 La Estancia De Tucson Lots 419-674 Final Plat Dear Scott: The above referenced project has been CONDITIONALLY APPROVED by the Community Design Review Committee. Please make any necessary corrections and submit the following documents: (2) Title reports current within the last thirty (30) days. (1) Executed Final Plat Double Matte Océ or Photo Mylar. (1) * Check in the amount of $8.50 per plat page for Mayor & Council distribution made payable to the local print company of your choice or provide an account number to charge. (1) * Check in the amount of $55.00 per plat page for recorded plat distribution made payable to the local print company of your choice or provide an account number to charge. (1) Check made payable to "Pima County Recorder" in the amount of $20.00 per plat page plus a $4.00 handling fee, along with CC&R fees if applicable. CC&R fees are $9.00 for the first 5 pages and $1.00 for each additional page. (1) Executed and notarized CC&R's document (if applicable). *Please do not combine the checks for the printing charges. They are processed at different times and require separate checks. An account number is also acceptable and you can include this information on your transmittal sheet when submitting the above listed items. Assurances (if applicable) must be reviewed by the City Attorney's Office prior to being presented to the Mayor and Council. Plats, CC&R's and assurances must be approved at the same Mayor and Council Meeting. Please expect 7 - 8 weeks from the date submitted to the date scheduled for Mayor and Council approval. PLEASE INCLUDE THE MEMO FOR THE RECORDERS OFFICE THAT DETAILS ALL THE LOCATIONS WHERE RECORDATION INFORMATION MUST BE FILLED ON THE FINAL PLATS FOR S06-067 AND S06-071. Should you have any questions, please call me at 791-5608 extension 1179. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 293-2115 Fp-approved |