Plan Number: S06-065
Parcel: Unknown

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW

Plan Number - S06-065
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/11/2006 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
07/13/2006 JOE LINVILLE LANDSCAPE REVIEW Denied 1) Add the CDRC case number and any related case numbers to the landscape and native plant preservation plans.
DS 2-07.2.1.B

2) All disturbed, grubbed, graded, or bladed areas not otherwise improved shall be landscaped, reseeded, or treated with an inorganic or organic ground cover to help reduce dust pollution. Revise landscape plan to identify inert ground cover materials for all common areas and the adjacent right-of-way area. LUC 3.7.2.7., DS 2-06.5.2.C

3) Show and identify any existing plants to remain in place on the landscape plan. DS 2-07.2.2.A.1.e

4) Submit a native plant preservation plan per LUC 3.8.6.2 and DS 2-15.3.4. The plan is to include a native plant inventory, A Plant Preservation and Salvage Plan, and Salvage and Mitigation Report. DS 2-15.2.0

5) Revise the landscape plans to show the limits of grading. DS 2-07.2.2.B.5
Limits are to be established at property lines and areas where protected plants are to be preserved.

6) Revise the site tabulations and bufferyard tabulations on L-3. Remove incorrect data.

Resubmittal of all plans is required, including a native plant preservation plan.
07/17/2006 JIM EGAN COT NON-DSD FIRE Approved
07/19/2006 FRODRIG2 PIMA COUNTY WASTEWATER Approv-Cond July 18, 2006

TO: Joaquín Rincón
Civil Works Engineering

THRU: Patricia Gehlen
City of Tucson, Development Services Department

FROM: Dickie Fernández, E.I.T.
Pima County Development Services Department
Development Review Division (Wastewater)

SUBJECT: Casitas at Liberty
Tentative Plat – 2nd Submittal
S06-065

The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


SHEET 2. Show the Pima County plan number for the existing public sewer shown on this sheet.

SHEET 2. Show the six-digit Pima County manhole number for the existing public manhole shown on this sheet.

Subject to the above required revisions, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the tentative plat.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Department of Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.



If you have any questions regarding the above mentioned comments, please contact me. Sincerely,





Dickie Fernández, E.I.T.
Telephone: (520) 740-6947

Copy: Project
07/19/2006 JOSE ORTIZ COT NON-DSD TRAFFIC Approved July 19, 2006
ACTIVITY NUMBER: S06-065
PROJECT NAME: Casitas at Liberty
PROJECT ADDRESS: 5031 S Liberty Ave
PROJECT REVIEWER: Jose E. Ortiz PE, Traffic Engineer

Traffic Engineering recommends approval of the Tentative Plat.


If you have any questions, I can be reached at 791-4259 x305 or Jose.Ortiz@tucsonaz.gov
08/01/2006 KAY MARKS PIMA COUNTY ADDRESSING Denied 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S06-065 CASITAS AT LIBERTY/REVISED TENTATIVE PLAT
DATE: 8/01/06



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:


Danny Drive is unacceptable due to sound-alike with Dan Place. Please choose a new street name and use the suffix of Place.






es
08/08/2006 GLYNDA ROTHWELL UTILITIES TUCSON ELECTRIC POWER Approved SUBJECT: CASITAS AT LIBERTY

Lots 1 - 12

S06-065



Tucson Electric Power Company (TEP) has no objection to the preliminary
plat resubmitted for review July 11, 2006.



The preliminary point where TEP will serve this project is from the pole
along Liberty Ave. Enclosed is a copy of TEP's facility map showing
the approximate location and unit numbers of the existing facilities.
There are conflicts with existing pole #264, a J1 (LRM-32), an UG
transformer (SMR-33), and the underground primary from the J1 to the
transformer and two underground service runs. Relocation of TEP poles
and/or equipment is 100% billable to the customer. Also enclosed is a
copy of the tentative plat showing where TEP will be placing the
aboveground equipment for this subdivision. This is not a preliminary
design. TEP has provided this drawing to show where the proposed
locations are for transformers and pedestals.



TEP will provide a preliminary electrical design on the Approved
Tentative Plat within Fifteen (15) working days upon receipt of the
plat. Additional plans necessary for preparation of the design are:
building plans including water, electrical, landscape, sidewalk and
paving plans. Also, submit the AutoCAD version of the plat on a CD or
email to kclark@tep.com <mailto:lcastillo@tep.com> . Should you have
any questions, please contact the Designer for this project Frank
Grijalva at (520) 918-8361.






Sincerely,








Kathy Clark


Scheduling Coordinator


Design/Build

kc

Enclosures

cc: P. Gehlen, City of Tucson

A. Espinosa, ESS Properties (Letter only)

F. Grijalva, Tucson Electric Power Co.





Kathy Clark
Scheduling Coordinator
Design/Build
520-918-8271
kclark@tep.com
08/14/2006 FRODRIG2 COT NON-DSD REAL ESTATE Approved S06-065 Casitas at Liberty Tentative Plat
No objection.
08/14/2006 GLENN HICKS COT NON-DSD PARKS & RECREATION Approved DATE: August 14 , 2006

TO: Ferne Rodriguez, Development Services

FROM: Glenn Hicks
Parks and Recreation
791-4873 ext. 215
Glenn.Hicks@tucsonaz.gov

CC:


SUBJECT: S06-065 Casitas at Liberty: Tentative Plat(7-11-06)


Approved.
08/28/2006 STEVE SHIELDS ZONING REVIEW Approv-Cond TO: Development Services Department Plans Coordination Office

FROM: Steve Shields
Lead Planner

PROJECT: CASITAS AT LIBERTY
S06-065
TENTATIVE PLAT - RESUBMITTAL

TRANSMITTAL DATE: August 28, 2006

DUE DATE: August 8, 2006

COMMENTS:

1. The Zoning Review Section approves the tentative plat for this subdivision, subject to the following changes on the executed tentative plat. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised tentative plat to verify that those changes do not affect any zoning requirements.

2. Per DS 2-03.2.1.D A small, project-location map will be provided, drawn at a scale of 3" = 1 mile. On multiple sheet drawings, the map will be located on the first sheet of the plat. Please provide the Project Location Map on the first sheet.

3. DS 2-03.2.4.I The existing easements as indicated are to be abandoned. Add to General Note 19, "PROVIDE RECORDATION INFORMATION (DOCKET & PAGE) ON THE FINAL PLAT".

If you have any questions about this transmittal, please call Steve Shields, (520) 791-5608 ext. 1180

C\planning\cdrc\finaplat\S06-065tp.doc
09/08/2006 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

September 8, 2006

Joaquin Rincon
Civil Works Engineering
515 East Grant Road #141-226
Tucson, AZ 85705

Subject: S06-065 Casitas at Liberty Tentative Plat

Dear Joaquin:

Your submittal of July 11, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLUELINES MUST BE FOLDED

4 Copies Revised Tentative Plat (Landscape, Addressing, Wastewater, DSD)

2 Copies Revised Landscape and Irrigation Plans (Landscape, DSD),

2 Copies NPPO Plans (Landscape, DSD),






Should you have any questions, please call me at 791-5608 ext. 1179.

Sincerely,


Patricia Y. Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/
Via fax: 628-7503
09/08/2006 LOREN MAKUS ENGINEERING REVIEW Approved DATE: September 8, 2006

To: Patricia Gehlen
CDRC/Zoning Manager
FROM: Loren Makus, EIT
Engineering Division

SUBJECT: Casitas At Liberty
Tentative Plat S06-065 (Second Review)
T15S, R13E, Section 01

RESUBMITTAL REQUIRED: None

The Tentative Plat and Drainage Report have been reviewed by the Engineering Division and we recommend approval at this time.
If you have any questions, I can be reached at 791-5550 x1161 or loren.makus@tucsonaz.gov.

Loren Makus, EIT
Senior Engineering Associate