Plan Review Detail
Review Status: Completed
Review Details: FINAL PLAT REVIEW
Plan Number - S06-050
Review Name: FINAL PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/15/2009 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 01/23/2009 | PGEHLEN1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Approved | |
| 01/27/2009 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Approved | Office of the Pima County Assessor 115 N. Church Ave. Tucson, Arizona 85701 BILL STAPLES ASSESSOR TO: CDRC Office Subdivision Review City of Tucson (FAX# 791-5559) FROM: Gary Ault, Mapping Supervisor Pima County Assessor’s Office Mapping Department DATE: 01/23/09 RE: Assessor’s Review and Comments Regarding Final Plat S06-050, Las Nubes, T13S-R13E-33 * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * x Plat meets Assessor’s Office requirements. _______ Plat does not meet Assessor’s Office requirements. COMMENTS: Thank you for your submittal. NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED. |
| 01/27/2009 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Denied | SUBJECT: LAS NUBES S06-050 Tucson Electric Power Company (TEP) has reviewed the final plat submitted January 15, 2009. TEP is unable to approve the plat at this time. In order for TEP to approve the final plat, the following will be required. * A 10' x 10' easement is required for the pedestal to serve Lot 5. Show the requested easement on the resubmittal of the final plat. Submit a copy to the City of Tucson for TEP's final approval. Please contact me at (520) 917-8745 if you have any questions. Liza Castillo, Right of Way Agent II Tucson Electric Power Co. Unisource Energy Services offc-(520) 917-8745 fax-(520) 545-1416 lcastillo@tep.com |
| 01/27/2009 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Denied | SUBJECT: LAS NUBES S06-050 Tucson Electric Power Co. (TEP) approves the attached final plat. Please forward any resubmittals of the final plat to this office. Please contact me at (520) 917-8745 if you have any questions. ________________________________ From: Jeff Stanley [mailto:stanley19263@msn.com] Sent: Thursday, March 05, 2009 1:18 PM To: Castillo, Liza Subject: Fw: Las Nubes final plat S06-050 Liza I meant to send this the other day. the easement shows up on sheet 3 thanks jeff |
| 01/27/2009 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Denied | Jeff Stanley brought the Mylar to me just now. TEP approves the Mylar. Thanks!! Liza Castillo, Right of Way Agent II Tucson Electric Power Co. Unisource Energy Services offc-(520) 917-8745 fax-(520) 545-1416 lcastillo@tep.com |
| 01/30/2009 | ANDY STEUART | COT NON-DSD | REAL ESTATE | Denied | Two items are requested: 1. Confirm the sole Owner/Developer is Luis Ybarra. The title report provided shows owners as Luis and Sally Ybarra (50%) and William Davis (50%). 2. As of 1/30/09, it appears property taxes are delinquant since 2007. Request taxes be shown as current before full approval is provided. |
| 01/30/2009 | ANDY STEUART | COT NON-DSD | REAL ESTATE | Denied | Hi Patricia Real Estate provides an "Approved" this Final Plat. Jeff Stanley showed me that taxes are current and ownership is now in trust, which satisfies my previous comments. I have no need to review the Mylar, unless you wish me to do so. Regards, Andy Steuart Property Agent Real Estate Program City of Tucson 201 N. Stone Ave. 6th Fl. Tucson, Arizona 85701 (O) 520.837.6715 (F) 520.791.5641 andy.steuart@tucsonaz.gov |
| 02/12/2009 | DAVID RIVERA | ZONING | REVIEW | Approved | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: David Rivera Principal Planner PROJECT: S06-050 Las Nubes Final Plat TRANSMITTAL DATE: February 12, 2009 DUE DATE: February 13, 2009 COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. An applicant has one (1) year from the date of approval of tentative plat to obtain approval of a final plat that complies with zoning and other development requirements in effect at the time of application. This final plat must be approved and recorded on or before February 12, 2010. 2. Label the rezoning case C9-04-22 in the lower right corner of all final plat sheets. DS 2-03.6.2.K 3. If applicable add the Beneficiary. DS 2-03.6.C 4. In the approval text block revise the word Approvals To Approval. Also revise the year from 2008 to 2009 in both the approval and recording data text blocks. Place the approval text block above the Recording Data text block. DS 2-03.6.3.D 5. Under the Assurances text block revise the following: Under the director signature line add the word DIRECTOR after the word department. Under the engineers signature line revise as follows: CITY OF TUCSON DEVELOPMENT SERVICES ENGINEERING ADMINISTRATOR. DS 2-03.6.3.E. 6. Add a street dimension at the narrowest portion of the street entrance to the subdivision. DS 2-03.6.4.A 7. Label common area "A". Define and label the natural undisturbed open space on the final plat as it is depicted on the approved tentative plat. (It is acknowledged that this open space is not part of the common open space.) DS 2-03.6.4.C 8. Label the erosion hazard setback line on the final plat and revise the erosion hazard setback line work under the Legend block to match the line on sheet two or visa versa. (thickness and darkness of the lines differ) DS 2-03.6.4.E 9. Label the 100 year flood prone line on the final plat and revise the 100 year flood prone line work under the Legend block to match the line on sheet two or visa versa. (thickness and darkness of the lines differ) DS 2-03.6.4.F 10. Corner lots may be designated with a star symbol indicating which street will be used for access. Use of this designation may limit design options for access. In instances where the City, for safety reasons, limits accessibility, a one (1) foot no access easement will be required. Address as required for all corner lots. DS 2-03.6.4.G 11. Show no-vehicular access easements where applicable. DS 2-03.6.4.H If you have any questions about this transmittal, please call David Rivera, (520) 791-5608. DGR C:\planning\cdrc\finalplat\S06050fp.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat |
| 02/12/2009 | DAVID RIVERA | ZONING | REVIEW | Approved | >>> David Rivera 03/05/2009 10:02 AM >>> Trish I had originally denied the final plat on my last review. I understand that my denial was changed to a conditional approval. I met with Jeff Stanley just now 9:45 and reviewed the changes and I can sat that he has revised the plans based on my comments. From a Zoning review perspective I approve the revised plans and good to go if Mylars are submitted. David David Rivera Principal Planner Development Services Department (520) 837-4957 david.rivera@tucsonaz.gov |
| 02/13/2009 | JASON GREEN | ENGINEERING | REVIEW | Denied | DATE: February 13, 2009 SUBJECT: Las Nubes Final Plat Submittal- Engineering Review TO: Patricia Gehlen, CDRC Manager LOCATION: 2740 W Goret Road, T13S R13E Sec 33 Ward 1 REVIEWERS: Jason Green, CFM ACTIVITY: S06-050 SUMMARY: Engineering Division of Development Services Department has received the proposed Final Plat, a copy of the Conditions, Covenants and Restrictions (CC&Rs) and a copy of the lot closure calculations. Engineering Division has reviewed the submitted Final Plat and CC&Rs and does not recommend approval of the Final Plat or CC&Rs at this time. The following items need to be addressed: FINAL PLAT COMMENTS: 1) DS Sec.2-03.6.1.A: Revise the final plat so that all mapped data is drawn having no more than 40 feet to the inch. Verify that all sheets are drawn at the same engineering scale for dimension verification. 2) DS Sec.2-03.6.1.B: Revise the Final Plat so that each sheet includes a 2-inch margin on the left side of each sheet to comply with standardization requirements of state law for recorded plats. 3) DS Sec.2-03.6.1.J: Revise Sheet 2 of the Final Plat and the labeled 100-year floodplain line and Erosion Hazard Setback Line to match the symbols used in the legend. Specifically the line weights must match the symbol line weight to reflect the nature of the line. 4) DS Sec.2-03.6.2.C: Revise General Note #3 to also include the verbiage "total miles of public streets as "0". 5) DS Sec.2-03.6.2.E: Provide the following note on the Final Plat; "Prior to issuance of any grading permit or building permit a Floodplain Use Permit is required for Lots 5, 6, 8, 9, 10, 11, 12, 13 and 14." The lots listed all have delineated floodplain and verification that no disturbance within the mapped floodplain is required at building plan submittal. 6) DS Sec.2-03.6.2.E: Provide the following note on the Final Plat; "Prior to issuance of any grading permit for the construction of the roadway improvements a Floodplain Use Permit is required to ensure that the improvements are built per the Drainage Report." 7) DS Sec.2-03.6.3.A: Acknowledged. However both Survey and Engineering statements must be sealed and signed by the professional at Mylar submittal. 8) DS Sec.2-03.6.3.B.1: Revise the Certification of Title paragraph to accurately read the following statement from the Development Standard section referenced, "We, the undersigned, hereby warrant that we are the owners and the only parties having any interest in the land shown on this plat, and we consent to the subdivision of said land in the manner shown hereon." Remove the wording "Title." 9) DS Sec.2-03.6.3.B.4: Revise the signature line to include a line for both parties that have an interest. Add a signature line for the Title Company with the name of the Trust Officer and a signature line for the property owner with the owner's name. 10) DS Sec.2-03.6.3.C: Revise the Final Platy to include a Beneficiary paragraph. The paragraph must state; "The beneficiary of (Title Company Name and Trust Number) is (Name and address)." 11) DS Sec.2-03.6.3.D: Revise the Recording Data paragraph and all other applicable Standard Paragraphs to read the correct year "2009." 12) DS Sec.2-03.6.3.E: Revise the Assurance paragraph to read per the referenced standard; "This is to certify that all improvements, such as streets, sidewalks, private sewers, water and utility installation, drainage and flood control facilities, and monuments, required by the City of Tucson have been completed or the future completion of such improvements has been assured by the posting of performance bonds, assurances, or other security as the City of Tucson deems necessary and proper." 13) DS Sec.2-03.6.3.E: Revise the Assurance paragraph to read per the referenced section and Department Directive; _____________________________________________ City of Tucson Development Services Department Director _________________________________________________________ City of Tucson Development Services Department Engineering Administrator 14) DS Sec.2-03.6.4.G: Corner lots may be designated with a star symbol indicating which street will be used for access. Use of this designation may limit design options for access. In instances where the City, for safety reasons, limits accessibility, a one (1) foot no access easement will be required. Address as required for all corner lots, specifically Lot 1. 15) DS Sec.2-03.6.5.C.1: Revise the Final Plat to show the Basis of Bearing line in plan view along the westerly line of Section 33 per the referenced General Note #5. 16) DS Sec.2-03.6.5.C.5: Revise the Final Plat to clearly indicate whether the distance and bearings between monuments were measured or calculated for all property line boundary information. 17) DS Sec.2-03.6.6: Revise the proposed CC&Rs to provide specific language for the maintenance and responsibility of the private roadway. Revise the CC&Rs to provide the original signed package. The Final Plat can not be approved prior to original CC&Rs being submitted and approved. 18) DS Sec.2-03.7.1.G: The final plat cannot be scheduled for Mayor and Council consideration until Financial Assurances are submitted and approved. It is recommended that the Assurance be submitted now for review so that any correction required can be handled prior to Mylar submittal to help expedite the Mayor and Council meeting once the Mylar's are submitted. GENERAL COMMENTS: Provide a revised Final Plat, CC&R package and a Financial Assurance Package at re-submittal. The revised Final Plat, CC&Rs and Assurance Package must address the comments provided above. Include a comprehensive response letter addressing in detail responses to all of the above comments. Further comments may be generated upon resubmittal of the Final Plat, CC&Rs and Assurance Package. For any questions or to schedule a meeting I can be reached at 837-4929. Jason Green, CFM Senior Engineer Associate Engineering Division COT Development Services |
| 02/13/2009 | JGREEN2 | CC&R | CC&R's | Denied | DATE: February 13, 2009 SUBJECT: Las Nubes Final Plat Submittal- Engineering Review TO: Patricia Gehlen, CDRC Manager LOCATION: 2740 W Goret Road, T13S R13E Sec 33 Ward 1 REVIEWERS: Jason Green, CFM ACTIVITY: S06-050 SUMMARY: Engineering Division of Development Services Department has received the proposed Final Plat, a copy of the Conditions, Covenants and Restrictions (CC&Rs) and a copy of the lot closure calculations. Engineering Division has reviewed the submitted Final Plat and CC&Rs and does not recommend approval of the Final Plat or CC&Rs at this time. The following items need to be addressed: FINAL PLAT COMMENTS: 1) DS Sec.2-03.6.1.A: Revise the final plat so that all mapped data is drawn having no more than 40 feet to the inch. Verify that all sheets are drawn at the same engineering scale for dimension verification. 2) DS Sec.2-03.6.1.B: Revise the Final Plat so that each sheet includes a 2-inch margin on the left side of each sheet to comply with standardization requirements of state law for recorded plats. 3) DS Sec.2-03.6.1.J: Revise Sheet 2 of the Final Plat and the labeled 100-year floodplain line and Erosion Hazard Setback Line to match the symbols used in the legend. Specifically the line weights must match the symbol line weight to reflect the nature of the line. 4) DS Sec.2-03.6.2.C: Revise General Note #3 to also include the verbiage "total miles of public streets as "0". 5) DS Sec.2-03.6.2.E: Provide the following note on the Final Plat; "Prior to issuance of any grading permit or building permit a Floodplain Use Permit is required for Lots 5, 6, 8, 9, 10, 11, 12, 13 and 14." The lots listed all have delineated floodplain and verification that no disturbance within the mapped floodplain is required at building plan submittal. 6) DS Sec.2-03.6.2.E: Provide the following note on the Final Plat; "Prior to issuance of any grading permit for the construction of the roadway improvements a Floodplain Use Permit is required to ensure that the improvements are built per the Drainage Report." 7) DS Sec.2-03.6.3.A: Acknowledged. However both Survey and Engineering statements must be sealed and signed by the professional at Mylar submittal. 8) DS Sec.2-03.6.3.B.1: Revise the Certification of Title paragraph to accurately read the following statement from the Development Standard section referenced, "We, the undersigned, hereby warrant that we are the owners and the only parties having any interest in the land shown on this plat, and we consent to the subdivision of said land in the manner shown hereon." Remove the wording "Title." 9) DS Sec.2-03.6.3.B.4: Revise the signature line to include a line for both parties that have an interest. Add a signature line for the Title Company with the name of the Trust Officer and a signature line for the property owner with the owner's name. 10) DS Sec.2-03.6.3.C: Revise the Final Platy to include a Beneficiary paragraph. The paragraph must state; "The beneficiary of (Title Company Name and Trust Number) is (Name and address)." 11) DS Sec.2-03.6.3.D: Revise the Recording Data paragraph and all other applicable Standard Paragraphs to read the correct year "2009." 12) DS Sec.2-03.6.3.E: Revise the Assurance paragraph to read per the referenced standard; "This is to certify that all improvements, such as streets, sidewalks, private sewers, water and utility installation, drainage and flood control facilities, and monuments, required by the City of Tucson have been completed or the future completion of such improvements has been assured by the posting of performance bonds, assurances, or other security as the City of Tucson deems necessary and proper." 13) DS Sec.2-03.6.3.E: Revise the Assurance paragraph to read per the referenced section and Department Directive; _____________________________________________ City of Tucson Development Services Department Director _________________________________________________________ City of Tucson Development Services Department Engineering Administrator 14) DS Sec.2-03.6.4.G: Corner lots may be designated with a star symbol indicating which street will be used for access. Use of this designation may limit design options for access. In instances where the City, for safety reasons, limits accessibility, a one (1) foot no access easement will be required. Address as required for all corner lots, specifically Lot 1. 15) DS Sec.2-03.6.5.C.1: Revise the Final Plat to show the Basis of Bearing line in plan view along the westerly line of Section 33 per the referenced General Note #5. 16) DS Sec.2-03.6.5.C.5: Revise the Final Plat to clearly indicate whether the distance and bearings between monuments were measured or calculated for all property line boundary information. 17) DS Sec.2-03.6.6: Revise the proposed CC&Rs to provide specific language for the maintenance and responsibility of the private roadway. Revise the CC&Rs to provide the original signed package. The Final Plat can not be approved prior to original CC&Rs being submitted and approved. 18) DS Sec.2-03.7.1.G: The final plat cannot be scheduled for Mayor and Council consideration until Financial Assurances are submitted and approved. It is recommended that the Assurance be submitted now for review so that any correction required can be handled prior to Mylar submittal to help expedite the Mayor and Council meeting once the Mylar's are submitted. GENERAL COMMENTS: Provide a revised Final Plat, CC&R package and a Financial Assurance Package at re-submittal. The revised Final Plat, CC&Rs and Assurance Package must address the comments provided above. Include a comprehensive response letter addressing in detail responses to all of the above comments. Further comments may be generated upon resubmittal of the Final Plat, CC&Rs and Assurance Package. For any questions or to schedule a meeting I can be reached at 837-4929. Jason Green, CFM Senior Engineer Associate Engineering Division COT Development Services |
| 02/17/2009 | FERNE RODRIGUEZ | PDEQ | PIMA COUNTY DEPT OF ENVIRONMENTAL QUALITY | Approv-Cond | MEMORANDUM PIMA COUNTY DEVELOPMENT REVIEW DEPARTMENT OF ENVIRONMENTAL QUALITY SECTION DATE: February 17, 2009 TO: City of Tucson, Subdivision Coordinator FROM: Robert E. Flynt, Public Works Mgr. SUBJECT: Las Nubes, Lots 1-14 Plat # S06-050 We have reviewed the above-referenced submittal and have no objection to its approval subject to the following comments, which may be addressed on the Quality Assurance Routing submittal: Please add a General Note as follow: Sewage disposal for lots 1 – 14 will be on-site disposal systems. Any grading land clearing or earthmoving of more than one acre, more than 50 feet of road construction, or more than 300 feet of trenching will require an Air Quality Activity Permit. These permits must be obtained prior to commencement of construction. |
| 02/20/2009 | JENNIFER STEPHENS | PIMA COUNTY | ADDRESSING | Denied | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 JENNIFER STEPHENS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: JENNIFER STEPHENS, ADDRESSING OFFICIAL SUBJECT: S06-050 LAS NUBES/FINAL PLAT DATE: 2/19/09 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval: Delete “a subdivision of parcels” and parcel numbers from Location Map. Delete parcel numbers for surrounding properties on all applicable sheets. Label Black Cloud Court on sheet 3. |
| 02/20/2009 | JENNIFER STEPHENS | PIMA COUNTY | ADDRESSING | Denied | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 JENNIFER STEPHENS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: JENNIFER STEPHENS, ADDRESSING OFFICIAL SUBJECT: S06-050 LAS NUBES/REVISED FINAL PLAT DATE: 03/05/09 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project. Submit a 24 x 36 Reverse Reading Double Matte Photo Mylar of approved Development Plan to City Planning. Signed and dated Mylar will be forwarded to Pima County Addressing prior to assignment of addresses. 2.) All addresses will need to be displayed per Pima County Address Standards at the time of final inspection. |
| 02/24/2009 | RONALD BROWN | ZONING HC SITE | REVIEW | Approved | A. Insure Compliance with Inclusive Home Design Ordinance 10463 and add a note to the final mylars to that effect. B. Please reference the two code requirements below: 1. As per Section 1003.2, Provide at least one accessible entrance on an accessible route from public…areas. 2. Reference Section 103.1, Wavier of Provisions in this Standard. Ronald Brown |
| 02/24/2009 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES February 24, 2009 Jeffrey A. Stanley Stanley Engineering & Drainage PO Box ???? Tucson, Arizona 85702 Subject: S06-050 Las Nubes Final Plat Dear Jeffrey: The above referenced project has been CONDITIONALLY APPROVED by the Community Design Review Committee. Please make any necessary corrections and submit the following documents: (2) Title reports current within the last thirty (30) days. (1) Executed Final Plat Double Matte Océ or Photo Mylar. (1) * 81/2"X11" copy of plat (1) * Check in the amount of $20.00 per plat page for recorded plat distribution made payable to the local print company that has access to Pima County Recorders on line platting system or provide an account number to charge. (1) Check made payable to "Pima County Recorder" in the amount of $20.00 per plat page plus a $4.00 handling fee, along with CC&R fees if applicable. CC&R fees are $9.00 for the first 5 pages and $1.00 for each additional page and fees for consent(s) to dedicate, if applicable. (2) Executed and notarized CC&R's document (if applicable) and Assurance Package (if applicable). One original set and one copy of each. Assurances (if applicable) must be reviewed by the City Attorney's Office prior to being presented to the Mayor and Council. Plats, CC&R's and assurances must be approved at the same Mayor and Council Meeting. Please expect 5-6 weeks from the date submitted to the date scheduled for Mayor and Council approval. THIS FINAL PLAT MUST BE APPROVED AND RECORDED BY MARCH 17, 2009 PER LUC 4.1.7.3. A CONDITIONAL APPROVAL HAS BEEN GRANTED ON THE CONDITION THAT THE PLAT MOVES FORWARD QUICKLY. PRIOR TO SUBMITTAL TO THE CDRC OFFICE, THE FINAL PLAT MYLARS MUST BE REVIEWD AND APPROVED BY TEP, REAL ESTATE, PC ADDRESSING. THE APPROVALS MUSTBE IN WRITING (E-MAIL IS OKAY). Should you have any questions, please call me at 837-4919. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 792-0318 |