Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Plan Number - S06-050
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/21/2007 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 08/23/2007 | JASON GREEN | ENGINEERING | REVIEW | Approved | DATE: September 24, 2007 SUBJECT: Las Nubes Tentative Plat- 4th Engineering Review TO: Patricia Gehlen, CDRC Manager LOCATION: 2740 W Goret Road, T13S R13E Sec33 Ward 1 REVIEWER: Jason Green, CFM ACTIVITY: S06-050 SUMMARY: Engineering Division of Development Services Department has received the revised Tentative Plat, Hydrology/Hydraulic Report (Stanley Engineering and Drainage, Inc., 31MAY07 revised 17AUG07), Pavement Section Design Geotechnical Report (Pattison-Evanoff Engineering, LLC, 11APR05), Preliminary Development Plan, DSMR approval, the homeowners letter of intent for the $30,0000 contribution, and Title Report. Engineering Division recommends approval of the Tentative Plat at this time. The Drainage Report was reviewed for Tentative Plat purposes only. § DS Sec.2-03.2.2.B.3: Engineering Division has received the letter from the property owner stating their intent of contributing the $30,000 towards the cost of a traffic signal at the intersection of Goret Road and Silverbell Road, this is required prior to Final Plat approval. Please contact Thomas Weiderman at 837-6617 for further clarification. § A Floodplain Use Permit will be required with the grading plan application for all work proposed in the floodplain or erosion hazard area. If you have any questions, I can be reached at 520-837-4929. Jason Green, CFM Senior Engineer Associate Engineering Division Development Services |
| 09/14/2007 | JOE LINVILLE | LANDSCAPE | REVIEW | Denied | 1) Along the scenic route, exposed cut or fill slopes shall be no greater than a one (1) foot rise or fall over a three (3) foot length. Clarify how the entrance street complies with the 3:1 slope requirement. LUC 3.7.5.2.E 2) When using the Set Aside Methodology an Environmental Resource Report (ERR) per Development Standard 1-07.0 and in conformance with Development Standard 2-15.3.5 shall be prepared for the entire site to determine the general viability, density, and variety of Protected Native Plants within areas on the site. The Report shall include an assessment of areas of NUOS and shall prioritize the natural resource value of vegetated areas on the site in conformance with the intent and purpose of this Division. Provide an aerial photograph, taken within a maximum of three (3) years of submittal, is required at a minimum 1" = 100’ delineating the natural resource values for areas on the site and the area to be set aside which will be platted and included in Covenants, Conditions, and Restrictions (CC&Rs) as NUOS. 3) Revise the ERR and the NPP plan to correspond regarding the number of existing saguaros on the site. 4) Per DS 2-15.2.6.C Privately owned individual residential lots that are greater than 24,000 square feet may include Protected Riparian Area where (i) the Protected Riparian Area is delineated on the plat providing a surveyed description of the location within each lot, and (ii) there is a note on the plat requiring that each purchaser of a lot shall sign a disclosure form acknowledging the prohibition upon development in the Protected Riparian Area and no walls or fences are constructed within the Protected Riparian Areas. Delineate the Protected Riparian Area per DS 2-13 on the Tentative Plat and add the required disclosure to the plat. |
| 09/21/2007 | DAVID RIVERA | ZONING | REVIEW | Approved | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: David Rivera Principal Planner PROJECT: S06-050 Las Nubes Lots 1 - 14 and Common Areas A, B, C, and D Tentative Plat TRANSMITTAL DATE: September 21, 2007 DUE DATE: September 20, 2007 COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. The Zoning Review Section approves the final plat for this subdivision. Should there be any changes requested by other CDRC members, however, the Zoning Review Section approval is void, and we request copies of those changes to insure that those changes do not affect zoning requirements. If you have any questions about this transmittal, please call David Rivera, (520) 791-5608. C:\planning\cdrc\finalplat\S06050fpa.doc |
| 10/01/2007 | FRODRIG2 | PDEQ | PIMA COUNTY DEPT OF ENVIRONMENTAL QUALITY | Approved | Memo on file. |
| 10/03/2007 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES October 3, 2007 Jeff Stanley Stanley Engineering and Drainage PO Box 1888 Tucson, AZ 85702 Subject: S06-050 Las Nubes Tentative Plat Dear Jeff: Your submittal of August 21, 2007 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLUELINES MUST BE FOLDED 2 Copies Revised Tentative Plat (Landscape, DSD) 2 Copies Revised Landscape and Irrigation Plans (Landscape, DSD), 2 Copies Revised NPPO Plans (Landscape, DSD), 2 Copies Environmental Resource Report (Landscape, DSD) Should you have any questions, please call me at 837-4919. Sincerely, Patricia Y. Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 792-0318 |