Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Plan Number - S06-045
Review Name: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/27/2006 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 07/10/2006 | JOSE ORTIZ | ENGINEERING | REVIEW | Approv-Cond | DATE: July 10, 2006 TO: Patricia Gehlen, CDRC Manager FROM: Jose E. Ortiz, Civil Engineering SUBJECT: Engineering review of the La Playa Condominium Final Plat. The act # is S06-045. RESUBMITTAL REQUIRED: Final Plat (Mylar) Engineering has reviewed the received items and recommends a conditional approval of the Final Plat. 1. Course and distance will tie at least one (1) corner of the site to a section corner, a quarter section corner, or an established City survey monument. The plat must include a description of that corner marker and an indication of how the bearings were determined. Corner tie recordation information is to be provided on the plat. DS 2-03.6.5.A. It appears Speedway Blvd or Dodge Blvd will meet this standard therefore label either leg appropriately to meet this standard. If you have any questions, I can be reached at 791-5640 ext. 1191 or jose.ortiz@tucsonaz.gov Jose E. Ortiz, PE Civil Engineer |
| 08/04/2006 | FRODRIG2 | COT NON-DSD | REAL ESTATE | Approved | S06-045 La Playa Condominiums: Resubmittal - CDRC - Final Plat Review - Request confirmation that legal access is available to on-site parking located at the N. area of Subject Parcel. R.O.W. Agreement, Doc. 1863 Pg. 544, appears valid. However, access is currently denied by a closed gate at the NEC of Parcel 125-11-0810 (Lot 9 Blk. 2, E. Speedway Add.). |
| 08/04/2006 | FRODRIG2 | COT NON-DSD | REAL ESTATE | Approved | S06-045 La Playa Condominiums: Resubmittal - CDRC - Final Plat Review ***Refer to my previous 8/2/06 e-mail, same subject*** Confirmation has been provided that legal access is available and the concern is satisfied. Please withdraw the words in the 8/2/06 comments. RE has no additional comment. |
| 08/28/2006 | STEVE SHIELDS | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Steve Shields Lead Planner PROJECT: LA PLAYA CONDOMINIUMS - S06-045 FINAL PLAT - RESUBMITTAL TRANSMITTAL DATE: August 25, 2006 DUE DATE: July 26, 2006 COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. An applicant has one (1) year from the date of the submittal to obtain approval of a final plat that complies with zoning and other departments requirements in effect at the time of application. This final plat must be approved and recorded on or before March 26, 2007. 2. DS 2-03.6.1.K This project has been assigned the subdivision case number S06-045. Please list the case number in the lower right corner of all final plat sheets. This was not provided with this submittal. 3. In regards to the parking located to the north of the existing buildings either: A. The owner will need to provide proof that the issues with the existing 20' access easement have been resolved (current LUC requirements are for a 24' wide PAAL for two way traffic, and it is acknowledged that the existing 20' easement is nonconforming) or B. That the parking has been removed and the play area installed. A zoning inspection will be required. One of the two options will need to be completed prior to approval of the final plat. 4. Please provide written documentation on how section 4.1.9.2. of the LUC will be met with this proposed condominium conversion project. If you have any questions about this transmittal, please call Steve Shields, (520) 791-5608 ext. 1180 C\planning\cdrc\finaplat\S06-045fp.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat, CC&R's and additional requested documents. |
| 08/29/2006 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES August 29, 2006 Thomas E. Guido, P.E. T and T Engineering, LLC 5980 East Verde Place Tucson, AZ 85750 Subject: S06-045 La Playa Condominiums Final Plat Dear Tom: Your submittal of June 27, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLUELINES MUST BE FOLDED 2 Copies Revised Final Plat (Zoning, DSD) 2 Copies Affidavits (Zoning, DSD) Should you have any questions, please call me at 791-5608 ext. 1179. Sincerely, Patricia Y. Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 577-0929 |