Review Date Reviewer's Name Type of Review Description Status Comments
02/27/2006 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
03/01/2006 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Approved SUBJECT: LA PLAYA APARTMENTS

S06-045



Tucson Electric Power Company has reviewed and approved the final plat
submitted February 27, 2006.



In order to apply for electric service, call the New Construction
Department at (520) 918-8300. Submit a final set of plans including
approved site, offsite and electrical load plans. Include a CD with the
AutoCAD version of the plans. If easements are required, they will be
secured by separate instrument. Your final plans should be sent to:



Mike Kaiser

Design/Build - DB 102

Tucson Electric Power
Company

P. O. Box 711

Tucson, AZ 85702



Please call me at (520) 917-8745, should you have any questions.


Liza Castillo
Right of Way Agent
Land Management
Tucson Electric Power Co.
(520) 917-8745
lcastillo@tep.com
03/10/2006 FRODRIG2 PIMA COUNTY WASTEWATER Approv-Cond March 9, 2006

To: Tom Guido, T & T Engineering

Thru: Patricia Gehlen, CDRC Project Manager
City of Tucson Development Services Department

____________________________________
From: Michael J. Harrington, representing the Pima County
Departments of Wastewater Management and Environmental Quality

Subject: La Playa Condominiums
Units 1-16, Common Elements and Limited Common Elements (Yard Area)
Final Plat - 1st Submittal
S06-045

The proposed final plat for the above-referenced project has been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.



This project will be tributary to the Roger Road Wastewater Treatment Facility via the South Rillito - West (South Line) Interceptor. Per written guidance provided by the PCWMD Development Services Section, sufficient conveyance and treatment capacity exists in the downstream public sewerage system for this project, and a formal capacity response letter from the PCWMD will not be required for this small project. The on-site sewers are existing and private. No new public sewers are proposed for this apartment to condominium conversion project.

Sheet 1: Revise the Dedication block, 4th paragraph, last sentence so that:

PRIVATE SEWERS are included as part of the list of COMMON ELEMENTS that the ASSOCIATION will accept responsibility for managing, controlling and maintaining.

Subject to the above, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the final plat. The required revision(s) may be shown on the Mylars.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.


If you have any questions regarding the above mentioned comments, please contact me at the telephone number shown under my signature on the first page of this letter

CC: Project File
03/21/2006 KAY MARKS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S06-045 LA PLAYA APARTMENTS / FINAL PLAT
DATE: March 21, 2006



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:

1: Label Condominium Units per Pima County Code (see attachment).

2: Delete direction (E) from 2nd Street on sheet 2.
03/21/2006 KAY MARKS PIMA COUNTY ADDRESSING Approved ADDRESS STANDARDS 18.83.040

5)Condominiums:
a)Condominium developments shall be assigned a situs address for each building.
b)Individual living facilities in each building shall be assigned occupant identifiers (unit numbers): First floor units shall have 100 series numbers, second floor units shall have 200 series numbers, and additional floors shall be numbered accordingly.
03/27/2006 FRODRIG2 COT NON-DSD REAL ESTATE Denied S06-045 La Playa Apartments: Final Plat Review. The following items are of concern:

-Easement Doc./Pg. 139/284, is not identified on Plat.
-Onsite vehicle parking not annotated.
-Vehicle entryway onto E. 2nd. Street is not annotated.
-Vehicle entryway to the N. parking not identified.
-Physical access is denied to the E. 20' of Lot 9/Blk. 2, E. Speedway Addition, per Doc./Pg. 1863/544 (Rcrd. 12/4/61).
-Request for confirmation of legal and physical access to the N. parking area. Current access is apparently using parcels to the N.
03/27/2006 JOSE ORTIZ ENGINEERING REVIEW Denied DATE: March 26, 2006

TO: Patricia Gehlen, CDRC Manager

FROM: Jose E. Ortiz, Civil Engineering

SUBJECT: Engineering review of the La Playa Condominium Final Plat. The activity number is S06-045.

RESUBMITTAL REQUIRED: Final Plat

Engineering has reviewed the received items and does not recommend approval of the Final Plat.

1. Approval DS 2-03.6.3.D

q APPROVAL
The following signature block may be needed along with the remainder of the approval block.


q (Name of current Recorder) .
Pima County Recorder Deputy County Recorder



2. Assurances. DS 2-03.6.3.E

The following ASSURANCE block must be placed on the plat's first sheet.

q ASSURANCES
"This is to certify that all improvements, such as streets, sidewalks, sewers, water and utility installation, drainage and flood control facilities, and monuments, required by the City of Tucson have been completed or the future completion of such improvements has been assured by the posting of performance bonds, assurances, or other security as the City of Tucson deems necessary and proper."

_______________________________________________
q City of Tucson Development Services Department Director

_______________________________________________
q City of Tucson Engineer


3. If applicable show detention/retention areas in a surveyable and readily retraceable manner. DS 2-03.6.4.I

4. Show all known existing and proposed easements.

5. Indicate in the title block what the various common elements are on the site (for example parking, drainage, recreational area, etc.). If the site contains a retention or detention basis then the boundaries of the basis must be illustrated in a surveyable manner.

6. Callout the 'CONDOMINIUM UNIT DETAIL' within the horizontal plan view of the condominium unit layout.

PROTECTIVE COVENANTS OR COVENANTS, CONDITIONS, AND RESTRICTIONS (CC&RS)

1. Are there assigned parking via the CC&R's Section 13.21 and Section 2.4? If assigned parking exist then the final plat may need to be modified to reflect the location of this assigned parking and may need to be designated as a limited common element and not a common element as shown on the final plat.



If you have any questions, I can be reached at 791-5640 ext. 1191 or jose.ortiz@tucsonaz.gov

Jose E. Ortiz, PE
Civil Engineer
05/04/2006 TERRY STEVENS ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Terry Stevens
Lead Planner

PROJECT: S06-045
La Playa Condominiums
Final Plat

TRANSMITTAL: 05/04/06

DUE DATE: 3/27/06

COMMENTS:

1. An applicant has one (1) year from the date of submittal to obtain approval of a final plat that complies with zoning and other development requirements in effect at the time of application. This final plat must be approved and recorded on or before 3/26/07.

2. DS 2-03.6.1.K This project has been assigned the subdivision case number S06-045. Please list the case number in the lower right corner of all final plat sheets.

3. The last approved site plan submitted dated 1959 does not appear to reflect the site conditions at present. The area on the north side of the buildings, according to the last site plan, was for a play area. The aerial photos indicate that this area has at some time in the past been converted to a vehicular parking area. The same photos indicate a roof structure has been added to the west side of unit number 15 (the second unit from the south on the west set of buildings). The indicated swimming pool appears has been filled in. If the submitted last approved site plan is not the most current plan please submit the stamped and approved site plan that addresses the above issues.

If the above mentioned roofed structure is an enclosed room it becomes a portion of unit number 15 and must be included in the square footage and cubic footage matrix. The square footage of the limited common area for this unit then would need to be reivised. If it is a open porch in a limited common area clearly indicate it as such.

If there is not a stamped and approved site plan that addresses the above issues a new site plan will be required to be submitted, stamped and approved by DSD before approval of the final plat can be completed. Some of the issues that may arise if a new site plan is submitted for are:
1. A DDO may be required for the structure added to unit #15. It appears to be built to close to the property line.
2. Full LUC code compliance for the entire site may be required if the vehicular use area has been expanded greater than 25%.
3. How are the new parking spaces on the north side of the buildings being provided with access to the site?
4. If access is being provided from the property to the northeast, how has the access affected that property. Is there a cross access agreement with this property owner?

One other option is to return the property to match the approved site plan from 1959. A demo permit could be secured for the swimming pool if one had not been obtained previously.

4. DS 2-03.6.3.C Label each common area individually with a separate letter designation.

5. Please provide written documentation on how sections 4.1.9.1. and 4.1.9.2. of the LUC will be met with this proposed condominium conversion project.

6. Per DS 2-03.6.2.J, provide note "This subdivision is subject to Ordinance No 2658 , which established zoning in the Pima - 22nd St.- City Limits - Craycroft Rd. Annexation Area."

If you have any questions about this transmittal, please call Terry Stevens, (520) 791-5550 ext. 2000.


TLS C:\planning\cdrc\finalplat\S06-045fp.doc
05/05/2006 ED ABRIGO PIMA COUNTY ASSESSOR Approved Office of the Pima County Assessor
115 N. Church Ave.
Tucson, Arizona 85701

BILL STAPLES
ASSESSOR




TO: CDRC Office
Subdivision Review
City of Tucson (FAX# 791-5559)

FROM: Gary Ault, Mapping Supervisor
Pima County Assessor’s Office
Mapping Department

DATE: May 5, 2006


RE: Assessor’s Review and Comments Regarding Final Plat
S06-045 La Playa Condominiums T141409 (125-11)

* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

X Plat meets Assessor’s Office requirements.
_______ Plat does not meet Assessor’s Office requirements.


COMMENTS: Thank you for your submittal.

NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.







Susan King
05/05/2006 FRODRIG2 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Passed WATER SUPPLY
Tucson Water has been designated by the State of Arizona, Department of Water Resources, as having an assured water supply. This does not mean that water service is currently available to the proposed development. This development lies within the exterior boundary of Tucson Water's planned 50-year service area. Therefore, water supply is assured.

WATER SERVICE
The approval of water meter applications is subject to the availability of water service at the time an application is made. The developer shall be required to submit a water master plan identifying but not limited to:

Water Use
Fire Flow Requirements
Offsite / Onsite Water Facilities
Loops and Proposed Connection Points to Existing Water System
Easements / Common Areas

Any specific area plan fees, protected main / facility fees and / or other needed facilities' cost are to be paid by the developer.

If the existing water system is not capable of meeting the requirements of the proposed development, the developer shall be fiscally responsible for modifying/enhancing the existing water system to meet those needs.

This letter shall be null and void one year from the date of issuance.

Issuance of this letter is not to be construed as agency approval of a water plan or as containing construction review comments relative to conflicts with existing water lines and the proposed development.

If you have any questions, please call New Development at 791-4718.

Sincerely,



Richard S. Williamson, P.E.
Manager, New Development
RW:bjh
05/05/2006 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

May 5, 2006

Thomas E. Guido, P.E.
T and T Engineering, LLC
5980 East Verde Place
Tucson, AZ 85750

Subject: S06-045 La Playa Condominiums Final Plat

Dear Tom:

Your submittal of February 27, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLUELINES MUST BE FOLDED

4 Copies Revised Final Plat (Real Estate, Zoning, Engineering, DSD)

2 Copies Affidavits (Zoning, DSD)




Should you have any questions, please call me at 791-5608 ext. 1179.

Sincerely,


Patricia Y. Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 577-1105