Plan Number: S06-025
Parcel: Unknown

Address:
2000 N 1ST AV

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - FINAL PLAT REVIEW

Plan Number - S06-025
Review Name: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/13/2006 MARILYN KALTHOFF START PLANS SUBMITTED Completed
07/11/2006 KAY MARKS PIMA COUNTY ADDRESSING Denied 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S06-025 RANCHO DEL SOL CONDOMINIUMS/REVISED FINAL PLAT
DATE: 7/11/06



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:



Change Mansfield Height Addition Book 7, Page 90 to Tucson Heights Book 2, Page 18 on pgs. 2 & 3 per letter dated 4-26-06.









es
07/17/2006 PETER MCLAUGHLIN ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office
FROM: Peter McLaughlin
Senior Planner

FOR: David Rivera
Principal Planner

PROJECT:
Rancho del Sol
S06-025
Final Plat

TRANSMITTAL: July 17, 2006
DUE DATE: July 12, 2006

The Zoning Review Section at the Development Services Department approves the final plat for this subdivision, subject to the following changes on the executed final plat. However, should there be any changes requested by other CDRC members, the approval is void, and we request copies of the revised final plat to verify that those changes do not affect any zoning requirements.


COMMENTS:

1. Label common element "A" on the drawings on sheets 2 and 3.
DS 2-03.6.4.C

If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608.
07/19/2006 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

July 19, 2006

Rick Murillo
Stantec Consulting, Inc.
201 North Bonita Avenue
Tucson, AZ 85745

Subject: S06-025 Rancho Del Sol Condominiums Final Plat

Dear Rick:

The above referenced project has been CONDITIONALLY APPROVED by the Community Design Review Committee. Please make the any necessary corrections and submit the following documents:

(2) Title reports current within the last (30) days.
(1) Executed Final Plat Double Matte Océ or Photo Mylar.
(1) * Check made to "Reproductions, Inc." in the amount of $8.50 per plat page for Mayor & Council distribution.
(1) * Check made to "Reproductions, Inc." in the amount of $55.00 per plat page for recorded plat distribution.
(1) Check made to "Pima County Recorder" in the amount of $20.00 per plat page plus a $4.00 handling fee, along with CC&R fees if applicable. CCR fees are $9.00 for the first 5 pages and $1.00 for each additional page.
(1) Executed and notarized CC&Rs (if applicable).

*Please do not combine the checks for "Reproductions, Inc.". They are processed at different times and require separate checks. An account number is also acceptable.

Assurances (if applicable) must be reviewed by the City Attorney's Office prior to being presented to the Mayor and Council. Plats, CCR's and assurances must be approved at the same Mayor and Council Meeting. Please expect 7-8 weeks from the date submitted to the date scheduled for Mayor and Council approval.

Prior to submittal of mylar, it is recommended that the CC&R's are provided to Paul Machado with DSD Engineering for review and approval.

Should you have any questions, please call me at 791-5608 ext. 1179.

Sincerely,

Patricia Y. Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/
Via fax: 750-7470