Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Plan Review Detail
Review Status: Completed
Review Details: TENTATIVE PLAT REVIEW
Plan Number - S06-020
Review Name: TENTATIVE PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/20/2006 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 01/20/2006 | JIM EGAN | COT NON-DSD | FIRE | Approved | The Tentative Plat is approved January 20, 2006. |
| 01/26/2006 | JCLARK3 | ENV SVCS | REVIEW | Approved | * No known landfill with in 1000 feet of this development. * Development is a lot split for three lots. (1.86 ac, 2.15 ac, and 3.0 ac) No idea of what the lots are for. Surrounding properties are commercial C-1. Note: ES cannot comment are the compliance of the development standards because no admenties are shown. |
| 01/27/2006 | TOM MARTINEZ | OTHER AGENCIES | AZ DEPT TRANSPORTATION | Approved | NO COMMENT S06-020 PHYSICAL RESOURCE ENGINEERING INC BROADWAY-STONER ********************************************************************* Confidentiality and Nondisclosure Notice: This email transmission and any attachments are intended for use by the person(s)/entity(ies) named above and may contain confidential/privileged information. Any unauthorized use, disclosure or distribution is strictly prohibited. If you are not the intended recipient, please contact the sender by e-mail, and delete or destroy all copies plus attachments. ********************************************************************* |
| 02/10/2006 | FRODRIG2 | OTHER AGENCIES | PIMA ASSN OF GOVTS | Approved | Estimated daily traffic in 24 hr period - 140 |
| 02/15/2006 | RICHARD WILLIAMSON | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Approv-Cond | Conditioned upon meeting Tucson Water requirements for water service. |
| 02/16/2006 | FRODRIG2 | COT NON-DSD | REAL ESTATE | Approved | S06-020 Broadway Stoner Tentative, No Comment |
| 02/17/2006 | ROGER HOWLETT | COT NON-DSD | COMMUNITY PLANNING | Approved | DEPARTMENT OF URBAN PLANNING & DESIGN Regarding SUBJECT: Community Design Review Committee Application CASE NUMBER: CASE NAME: DATE SENT S06-020 Broadway – Stoner 02/16/06 () Tentative Plat ( ) Development Plan () Landscape Plan ( ) Revised Plan/Plat ( ) Board of Adjustment () Other CROSS REFERENCE: C9-77-33 NEIGHBORHOOD PLAN: Pantano East Area Plan GATEWAY/SCENIC ROUTE: N/A COMMENTS DUE BY: February 17, 2006 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: () No Annexation or Rezoning Conditions, Not an RCP - No Comment ( ) Proposal Complies with Annexation or Rezoning Conditions ( ) RCP Proposal Complies With Plan Policies ( ) See Additional Comments Attached ( ) No Additional Comments - Complies With Planning Comments Submitted on: ( ) Resubmittal Required: ( ) Tentative Plat ( ) Development Plan ( ) Landscape Plan ( ) Other REVIEWER: K. Aragonez 791-4505 DATE: 2/7/2006 |
| 02/20/2006 | JOE LINVILLE | LANDSCAPE | REVIEW | Denied | 1) The screen wall required along the north property line is to be located on the property line in compliance with LUC 3.7.3.2.A. 2) Show the location of the water meter on the irrigation plan. Clarify that the irrigation equipment will be located within the property limits, except as permitted in adjacent right-of-way areas by the Department of Transportation. 3) The landscape plan should not include the required screen heights until a site/development plan is submitted. For example, the required screen height for a multi-unit storage facility is six feet. Other specific uses may require screens higher than those indicated. Revise as necessary. 4) The infrastructure and drainage improvements may precede site development. All areas disturbed by construction will need interim dust control such as hydroseeding. Clarify compliance with the dust control standards for such interim conditions on the landscape plan. LUC 3.7.2.7 5) Revise the native plant preservation plan to indicate the limits of phase 1 disturbance/grading. DS 2-15.3.4.A.1 |
| 02/21/2006 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Approved | Office of the Pima County Assessor 115 N. Church Ave. Tucson, Arizona 85701 BILL STAPLES ASSESSOR TO: CDRC Office Subdivision Review City of Tucson (FAX# 791-5559) FROM: Gary Ault, Mapping Supervisor Pima County Assessor’s Office Mapping Department DATE: February 21, 2006 RE: Assessor’s Review and Comments Regarding Tentative Plat S06-020 Broadway-Stoner T141511 (133-36) * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * X Plat meets Assessor’s Office requirements. _______ Plat does not meet Assessor’s Office requirements. COMMENTS: Thank you for your submittal. NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED. Susan King |
| 02/21/2006 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Approved | SUBJECT: Broadway - Stoner S06-020 Tucson Electric Power Company has reviewed and approved the tentative plat submitted January 20 , 2006. Attached is a pdf file of a TEP facilities map showing the approximate location of the existing facilities. There may be a conflict with the existing pole line along Broadway. All costs associated with the relocation of facilities in conflict will be billable to the developer. In order to apply for electric service, call the New Construction Department at (520) 918-8300. Submit a final set of plans including approved site, offsite and electrical load plans. Include a CD with the AutoCAD version of the plans. If easements are required, they will be secured by separate instrument. Your final plans should be sent to: Nancy DiMaria Design/Build - DB 102 Tucson Electric Power Company P. O. Box 711 Tucson, AZ 85702 Please call me at (520) 917-8745, should you have any questions. (The attached map is meant for general information use only, and does not necessarily depict the exact location or nature of any TEP facilities) Liza Castillo Right of Way Agent Land Management Tucson Electric Power Co. (520) 917-8745 lcastillo@tep.com |
| 02/21/2006 | KAY MARKS | PIMA COUNTY | ADDRESSING | Denied | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 KAY MARKS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: KAY MARKS, ADDRESSING OFFICIAL SUBJECT: S06-020 BROADWAY STONER/TENTATIVE PLAT DATE: February 17, 2006 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval: Change J. Las Placitas Townhouses Phase 1 to Bloodworth Addition on Location Map. Change O. Solano Estates N/A to 32/44 and T. Halcyon Acres 6/4 to 6/40 on Location Map. jg |
| 02/27/2006 | FRODRIG2 | PIMA COUNTY | WASTEWATER | Denied | February 24, 2006 TO: Daniel White Physical Resource Engineering THRU: Patricia Gehlen City of Tucson, Development Services Department FROM: Dickie Fernández, E.I.T. Pima County Development Services Department Development Review Division (Wastewater) SUBJECT: Broadway Stoner, Lots 1-3 and Common Area A Tentative Plat – 1st Submittal S06-020 The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. Provide a letter from PCWWM Planning Services, written within the past 90 days, stating that treatment and conveyance system capacity for this project is available. A capacity request form may be found at http://www.pima.gov/wwm/forms/docs/CapResponseRequest.pdf. ALL SHEETS. Add the project number, S06-020, to the title block of each sheet. This number should be shown larger or bolder than any cross-reference numbers. Based on the evaluation of the proposed sewer design, this project qualifies for Standard sewer connection fee rates. This tentative plat is incomplete. Follow the tentative Pima County tentative plat requirements for wastewater by adding the required general notes and showing the proposed sewer layout. We will require a revised set of drawings and a response letter addressing each comment. Additional comments may be made during the review of these documents. The next submittal of this project will be the 2nd submittal. A check for the review fee of this submittal in the amount of $100.00 made out to PIMA COUNTY TREASURER must accompany the revised set of bluelines and response letter. For any questions regarding the fee schedule, please go to http://www.pimaxpress.com/SubDivision/Documents/Fees.PDF where you may find the appropriate wastewater review fees at the bottom of page 1. If the number of sheets changes, please adjust the review fee accordingly. If you have any questions regarding the above mentioned comments, please contact me. Sincerely, Dickie Fernández, E.I.T. Telephone: (520) 740-6947 Copy: Project |
| 03/01/2006 | DALE KELCH | COT NON-DSD | TRAFFIC | Approved | Traffic Engineering recommends APPROVAL of this TP. D. Dale Kelch, PE Senior Engineering Associate Traffic Engineering Division (520)791-4259x305 (520)791-5526 (fax) dale.kelch@tucsonaz.gov |
| 03/03/2006 | PAUL MACHADO | ENGINEERING | REVIEW | Denied | To: Patricia Gehlen DATE: March 3, 2006 CDRC/Zoning Manager Engineering Division SUBJECT: Broadway and Stoner, 9725 E. Broadway Blvd. Tentative Plat S06-020 (First Review) T14S, R15E, Section 11 RESUBMITTAL REQUIRED: Tentative Plat and Drainage Report. The Tentative Plat (TP) and Drainage Report (DR) cannot be approved as submitted. Please address the following review comments prior to the next submittal. Tentative Plat: 1. Please include a response letter to the comments along with the corrected copies of the TP. 2. Please provide property description per D.S. 2-02.2.1.3. 3. Add note indicating that Baniff Wash and its tributary are subject to the W.A.S.H. wash ordinance for future development. 4. Label existing and future sight visibility triangles per D.S. 2-02.2.1.10. 5. Show all points of egress and ingress including locations and width of driveways and parking area access lanes (P.A.A.L.) per D.S. 2-02.2.1.11. 6. Please label all vehicular, bicycle, pedestrian, and handicapped circulation clearly identified per D.S. 2-02.2.1.12. 7. Show the limits of the 100-year floodplain and water surface elevation per D.S. 2-02.2.1.15. 8. Please list estimated cut & fill quantities per D.S. 2-02.2.1.17. 9. Please show dimensioned right-of-way, including any applicable Major Streets and Routes (MS&R) Plan right-of-way per D.S. 2-02.2.1.19. 10. Add the basin(s) maintenance responsibility note per S.M.D.D.F.M. 2.3.1.6 C 1 and 2 to the TP, if applicable. 11. Dimension from street monument lines to existing and proposed curbs, sidewalks, driveways, and utility lines per D.S. 2-02.2.1.21. 12. Show Tentative plat number (S06-020) on all sheets per D.S. 2-02.2.1.29. Drainage Report: 1. Please include a response letter to the comments along with the corrected copies of the DR. 2. This review was performed for Tentative Plat purposes only. 3. Eliminating the Ret/Det basins and draining directly into the Baniff Wash and its tributary would be preferred to aid the percolation rate. 4. Show the 100-year floodplain limits in a surveyable manner. 5. Show the ERZ setbacks. 6. If applicable, add the basin(s) maintenance responsibility note and checklist per S.M.D.D.F.M. 2.3.1.6 C 1 and 2 to the DR. If you have any questions, I can be reached at 791-5550 x1193 or Paul.Machado@ci.tucsonaz.govs Paul P. Machado Senior Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 791-5550 x1193 office (520) 879-8010 fax C:/9725 E. Broadway Blvd CDRC |
| 03/08/2006 | GLENN HICKS | COT NON-DSD | PARKS & RECREATION | Denied | DATE: March 7, 2006 TO: Ferne Rodriguez, Development Services FROM: Glenn Hicks Parks and Recreation 791-4873 ext. 215 Glenn.Hicks@tucsonaz.gov SUBJECT: S06-020 Broadway-Stoner: Tentative Plat Review(1-20-06) Please indicate a non-motorized public trail easement is being dedicated that corresponds with the 16’ access and utility easement along the west bank of Wrightstown Wash and the east bank of the tributary wash. |
| 04/06/2006 | HEATHER THRALL | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Heather Thrall Senior Planner PROJECT: S06-020 Broadway Stoner Subdivision Tentative Plat TRANSMITTAL DATE: April 6, 2006 DUE DATE: February 17, 2006 COMMENTS: 1. Section 4.1.7.1, LUC, permits a maximum of one year from the date of application to obtain approval of a tentative plat. If, at the end of that time, the tentative plat has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this tentative plat is January 19, 2007. 2. This project was reviewed for compliance with the Land Use Code (LUC), Development Standard (DS), International Building Code 2003 (IBC) and American National Standard Institute (ANSI). The formatting of this tentative plat was reviewed under DS 2-03. 3. Staff acknowledges the letter with the submittal advising of a recent city approved lot split of the subject parcel. Please provide a copy of that last approved lot split for the Southeast portion of this parcel, S05-060, with the resubmittal. 4. Per DS 2-03.2.1.D.3, show adjacent township/range/section numbers on location map. 5. Per DS 2-03.2.1.G, list case "S06-020" (from Development Services) near title block. 6. Change legal in title block to state the project is a "Resubdivision of Easterly Portion of Block 1 of Solano Estates", followed by book and page numbers already provided. 7. Per DS 2-03.2.2.B.7, list note: plat is designed to meet LUC Sec. 2.8.3, Major Streets and Routes Overlay zone, requirements. 8. Per DS 2-03.2.4.J, clarify if easements are going to remain and if public or private. 9. Provide copies of CCR's to ensure maintenance agreement done for common area. 10. Provide note "a separate site plan is required to be reviewed and approved by the City of Tucson for the development of each lot". Separate site review fees are applicable. 11. Should you have any questions about this review, contact me at Heather.Thrall@tucsonaz.gov or 791-4541x1156. Depending upon responses provided, further review comments may be forthcoming. If you have any questions about this transmittal, please call (520) 791-5608. C:\planning\cdrc\tentativeplat\S06-020tpa.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised tentative plat, CC&R's and/or additional requested documents. |
| 04/14/2006 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES April 14, 2006 Daniel White Physical Resource Engineering Inc. PO Box36985 Tucson, AZ 85740 Subject: S06-020 Broadway-Stoner Tentative Plat Dear Dan: Your submittal of January 20, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLUELINES MUST BE FOLDED 7 Copies Revised Tentative Plat (Landscape, Addressing, Parks and Recreation, Wastewater, Zoning, Engineering, DSD) 5 Copies Revised Landscape Plans (Engineering, Landscape, Parks and Recreation, Zoning, DSD) 2 Copies Revised NPPO Plans (Landscape, DSD) 2 Copies Revised Drainage Report (Engineering, DSD) Should you have any questions, please call me at 791-5608 ext. 1179. Sincerely, Patricia Y. Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 696-3250 |