Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Plan Number - S06-018
Review Name: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/02/2007 | KAY MARKS | PIMA COUNTY | ADDRESSING | Approved | PIMA COUNTY ADDRESSING 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 KAY MARKS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: KAY MARKS, ADDRESSING OFFICIAL SUBJECT: S06-018 ALAMO LOFTS/REVISED FINAL PLAT DATE: 12/29/06 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project. ***The Pima County Addressing Section can use digital CAD drawing files when submitted with your final plat Mylar. These CAD files can be submitted through the Pima County Subdivision Coordinator. The digital CAD drawing files expedite the addressing and permitting processes when we are able to insert this digital data into the County's Geographic Information System. Your support is greatly appreciated.*** ES |
| 01/17/2007 | PAUL MACHADO | ENGINEERING | REVIEW | Denied | To: Patricia Gehlen DATE: January 17, 2007 CDRC/Zoning Manager SUBJECT: Alamo Lofts, 6105 E. Pima Street Final Plat S06-018 (Second Review) T14S, R14E, Section 01 RESUBMITTAL REQUIRED: Final Plat. The Final Plat (FP) cannot be approved as submitted. Please address the following review comments prior to the next submittal. Final Plat: 1. Please include a response letter to the comments along with the corrected copies of the FP. 2. The following items are required in the assurance package if a Third Party Trust Agreement will be used and was not included in the recent re-submittal. · Title Report Submit the above documents containing original signatures, copies of the documents and signatures will not be forwarded to the City of Tucson attorney for review. 3. Correct the title block to match the plan views to read "Common Elements "A" and "B" instead of "Common Areas "A" and "B". The designations of the common elements are still labeled as "CA A or B" and so forth on the plan view instead of "CE A or B". Revise as required. 4. Indicate the name and width of each street, alley, easement (type) and drainageway within….per D.S. 2-03.6.4.A. 5. Provide location, dimensions, areas in square footage, and purposes of lots proposed for dedication….per D.S. 2-03.6.4.D. 6. Indicate tract boundary lines; right-of-way and centerlines of streets, easements and other R/W per….per D.S. 2-03.6.5.B. 7. Basis of Bearings - the purpose of the basis of the basis of bearings on a survey is to enable…. per D.S. 2-03.6.5.C.1.a. The basis of bearing on the plat plan view does not match the BOB in the description from the plat of Minarik Estates, Lot 1, recorded in Bk. 22 of Maps and Plats at Page 14 on sheet no. 1. 8. The title block of the plat must match the Subdivision Assurances verbatim. 9. Please submit a copy of the subdivision boundary closure calculations. Per previous comment. If you have any questions, I can be reached at 791-5550 x1193 or Paul.Machado@tucsonaz.gov Paul P. Machado Senior Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 791-5550 x1193 office (520) 879-8010 fax C:/6105 E. Pima St. FP 2 |
| 01/19/2007 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES January 19, 2007 Doug Schneider Rick Engineering Company 1745 East River Road, Suite 101 Tucson, Arizona 85718 Subject: S06-018 Alamo Lofts Final Plat Dear Doug: Your submittal of November 30, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLACKLINES MUST BE FOLDED 3 Copies Revised Final Plat (TEP, Engineering, DSD) Should you have any questions, please call me at 791-5608 extension 1179. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 322-6956 fpresubmittal |
| 11/29/2006 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 12/14/2006 | KAROL ARAGONEZ | ZONING | REVIEW | Approved | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Karol Aragonez Planner PROJECT: S06-018 Alamo Lofts Resubmittal Final Plat TRANSMITTAL DATE: December 14, 2006 DUE DATE: December 28, 2006 COMMENTS: The Zoning Review Section approves the final plat for this subdivision. Should there be any changes requested by other CDRC members, however, the Zoning Review Section approval is void, and we request copies of those changes to insure that those changes do not affect zoning requirements. If you have any questions about this transmittal, please call Karol Aragonez, (520) 791-5550, ext. 1197. KAA S:\zoning review\karol\planning\cdrc\finalplat\S06-018fpr.doc |
| 12/14/2006 | GLYNDA ROTHWELL | UTILITIES | TUCSON ELECTRIC POWER | Denied | SUBJECT: ALAMO LOFTS Units 1-22 S06-018 Tucson Electric Power Company (TEP) has reviewed the final plat submitted November 30, 2006. TEP is unable to approve the plat at this time. General note 8 should be included in the dedication. This easement must be dedicated. An offsite easement will be required for the electric line from the existing transformer (SUP-6) to the property line of this project. See the requirement as shown on the design mailed out December 5, 2006. Forward me a legal description for the offsite easement. Show the requested dedication on the resubmittal of the final plat. Submit two bluelines to the City of Tucson for TEP's final approval. Please contact me at (520) 917-8745 if you have any questions. Liza Castillo, Right of Way Agent Land Management Tucson Electric Power Co. Unisource Energy Gas & Unisource Energy Electric PH: (520) 917-8745 lcastillo@tep.com <mailto:lcastillo@tep.com> |
| 12/27/2006 | FRODRIG2 | PIMA COUNTY | WASTEWATER | Approv-Cond | December 26, 2006 To: Doug Schneider, Rick Engineering Thru: Patricia Gehlen, CDRC Project Manager City of Tucson Development Services Department From: Chandubhai C. Patel, P.E. Pima County Development Services Department Development review Division (Wastewater) Subject: Alamo Lofts Condominiums Units 1-22, Common Elements "A","B" & “C” And Limited Common Elements "A-1" thru "A-22" Final Plat – 2nd Submittal, S06-018 The proposed final plat for the above-referenced project has been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. Sheet 1: In the BENEFICIARY block, 1st paragraph, the Trust number should be 60293 rather than 60128 as shown. SUBJECT TO THE ABOVE, the Pima County Department of Environmental Quality and the Wastewater Management Department hereby approve the above referenced submittal of the Final Plat as received by us on November 29, 2006. The revision may be shown on the Mylars. Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality Department. Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating, or engaging in any activity which may cause or contribute to air pollution. If you have any questions regarding the above comments, please do not hesitate to contact me. Sincerely, Chandubhai C. Patel, P.E. Phone: 520-740-6563 Copy: Project File |