Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Plan Number - S06-018
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/17/2006 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 11/01/2006 | ROGER HOWLETT | COT NON-DSD | COMMUNITY PLANNING | Approved | DEPARTMENT OF URBAN PLANNING & DESIGN Regarding SUBJECT: Community Design Review Committee Application CASE NUMBER: CASE NAME: DATE SENT S06-018 Alamo Lofts 10/31/06 () Tentative Plat ( ) Development Plan () Landscape Plan ( ) Revised Plan/Plat ( ) Board of Adjustment () Other (NPPO) CROSS REFERENCE: C9-05-19 NEIGHBORHOOD PLAN: Arcadia-Alamo Area Plan GATEWAY/SCENIC ROUTE: N/A COMMENTS DUE BY: November 15, 2006 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: ( ) No Annexation or Rezoning Conditions, Not an RCP - No Comment ( ) Proposal Complies with Annexation or Rezoning Conditions ( ) RCP Proposal Complies With Plan Policies ( ) See Additional Comments Attached () No Additional Comments - Complies With Planning Comments Submitted on: 05/19/06 ( ) Resubmittal Required: ( ) Tentative Plat ( ) Development Plan ( ) Landscape Plan ( ) Other - Photos REVIEWER: D. Corral DATE: 10/31/06 |
| 11/09/2006 | JOE LINVILLE | LANDSCAPE | REVIEW | Denied | 1) Provide screening per LUC 3.7.2-I. When a new development is using an existing screen wall on an adjacent property to meet screening requirements, a copy of a recorded covenant for the wall is required. Once completed, provide a copy of recorded covenant and add the docket and page of recordation to the plat. DS 2-04.2.1.A.15 2) Revise the landscape plan to remove Leucophyllum laevigatum from the site visibility triangle. |
| 11/16/2006 | TERRY STEVENS | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Terry Stevens Lead Planner PROJECT: S06-018 Alamo Lofts Tentative Plat TRANSMITTAL: 11/16/06 DUE DATE: 5/25/06 COMMENTS: 1. List in the title block the "Limited Use Common Areas". Provide this in the required CC&Rs also. 2. The indicated height of 33'4" for the east building wall, as indicated on page 1 of 3 in the tabulations, does not match the provided elevations. The height of a wall is measured from the grade adjacent to the structure. If the indicated height of 33'4" is correct, the required setback from the east property line (3/4 the height of the structure) should then be 25' not as indicated on the plan as 24.5' and 24.63'. Clarify. 3. DS 2-05.2.4.K Clearly indicate the required width of all sidewalks. Minimum of 4' in width. Provide a cross reference note for the handicap ramp at the handicap parking access aisle located near the center of the project. 4. A DSMR has been applied for and approved. Provide the case number, date of approval and any conditions of the DSMR on the plan. Provide the case number near the lower right corner of each sheet. 5. DS 2-05.2.4.Q The bicycle parking as indicated on the plan is located on the sidewalk which is part of the pedestrian circulation path. Relocate. 6. Depending on changes to this plan and responses to the above comments further comments may be forth coming. If you have any questions about this transmittal, please call Terry Stevens, (520) 791-5550 @ ext. 2000. TLS C:\planning\cdrc\tentativeplat\S06-018-3tp.doc |
| 11/20/2006 | FRODRIG2 | COT NON-DSD | REAL ESTATE | Approved | S06-018 Alamo Lofts: Resubmittal - CDRC - Tentative Plat Review - No comment. |
| 11/21/2006 | PAUL MACHADO | ENGINEERING | REVIEW | Approved | |
| 11/24/2006 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES November 24, 2006 Chuck Martin Rick Engineering Company 1745 East River Road, #101 Tucson, AZ 85718 Subject: S06-018 Alamo Lofts Tentative Plat Dear Chuck: Your submittal of October 17, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLUELINES MUST BE FOLDED 3 Copies Revised Tentative Plat (Landscape, Zoning, DSD) 3 Copies Revised Landscape Plans (Landscape, Zoning DSD), If this tentative plat is not approved on or before January 12, 2007, a written request for a review extension must be submitted to and granted by the CDRC office. Should you have any questions, please call me at 791-5608 ext. 1179. Sincerely, Patricia Y. Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 322-6956 |