Review Details: FINAL PLAT REVIEW

Plan Number - S06-008
Review Name: FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/10/2006 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
01/17/2006 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Approved SUBJECT: BEAR CANYON CONDOMINIUMS

S06-008



The Final Plat for the subject project will meet this Company's easement
requirements.

Please forward any resubmittals of the final plat to this office.


Liza Castillo
Right of Way Agent
Land Management
Tucson Electric Power Co.
(520) 917-8745
lcastillo@tep.com
01/31/2006 RICHARD WILLIAMSON TUCSON WATER NEW AREA DEVELOPMENT REVIEW Approv-Cond Conditioned upon meeting Tucson Water requirements for water service.
02/07/2006 PAUL MACHADO ENGINEERING REVIEW Denied To: Patricia Gehlen DATE: February 7, 2006
CDRC/Zoning Manager
SUBJECT: Bear Canyon Condos, 9055 E. Catalina Hwy.
Subdivision Plat S06-008 (First Review)
T13S, R15E, Section 34

RESUBMITTAL REQUIRED: Subdivision Plat.

The Subdivision Plat (SP) cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Subdivision Plat:

1. Please include a response letter to the comments along with the corrected copies of the FP.
2. Remove (1) of the "ACKNOWLEDGMENT" paragraphs on the cover sheet.
3. Label the detention/retention basins as a separate common element and in a surveyable manner per D.S. 2-03.6.4.I.
4. Complete the City of Tucson case no. S06-008.
5. Submit a copy of the subdivision boundary closure calculations.
6. Add the basin(s) maintenance responsibility note per S.M.D.D.F.M. 2.3.1.6 C 1 and 2 to the FP.

Drainage Report:
1. The Drainage Statement has been accepted by engineering.

If you have any questions, I can be reached at 791-5550 x1193 or Paul.Machado@ci.tucsonaz.govs
Paul P. Machado
Senior Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 791-5550 x1193 office
(520) 879-8010 fax
C:/9055 E. Catalina Hwy. FP
02/09/2006 FRODRIG2 COT NON-DSD REAL ESTATE Denied S06-008, Bear Canyon Condo's; Development plans do not dedicate R/W, therefore the "Additional R/W Per Bear Canyon Development Plan" needs to be dedicated or recording information shown as to how it was dedicated. The name of the dedicator(s) needs to show as well as the name(s) of the lenders on the consent to subdivide.
02/09/2006 KAY MARKS PIMA COUNTY ADDRESSING Denied 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S06-008 BEAR CANYON CONDOMINIUMS/FINAL PLAT
DATE: February 8, 2006




The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:

The units on the Title Blocks do not match the existing Bear Canyon Apartments Development Plan, Are these incorrect?

18101 to 18108, 18201 to 18207 on Title Blocks does not match pg. 3.














jg
02/10/2006 ED ABRIGO PIMA COUNTY ASSESSOR Approved Office of the Pima County Assessor
115 N. Church Ave.
Tucson, Arizona 85701

BILL STAPLES
ASSESSOR




TO: CDRC Office
Subdivision Review
City of Tucson (FAX# 791-5559)

FROM: Gary Ault, Mapping Supervisor
Pima County Assessor’s Office
Mapping Department

DATE: February 10, 2006


RE: Assessor’s Review and Comments Regarding Final Plat
S06-008 Bear Canyon Condominiums T131534 (114-51)

* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

X Plat meets Assessor’s Office requirements.
_______ Plat does not meet Assessor’s Office requirements.


COMMENTS: Thank you for your submittal. Please remove all shading before recording this plat.

NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.







Susan King
02/27/2006 FRODRIG2 PIMA COUNTY WASTEWATER Approv-Cond February 23, 2006

To: Rick Murillo, Stantec

Thru: Patricia Gehlen, CDRC Project Manager
City of Tucson Development Services Department

____________________________________
From: Michael J. Harrington, representing the Pima County
Departments of Wastewater Management and Environmental Quality

Subject: Bear Canyon Condominium
Units 2101 to 2201 et al, and Common Elements "A" & "B"
Final Plat - 1st Submittal
S06-008

The proposed final plat for the above-referenced project has been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.



This project will be tributary to the Ina Road Water Pollution Control Facility via the North Rillito Interceptor. Treatment and conveyance capacity was allocated for this project, Bear Canyon Apartments, under development case number CD9-84-34N, and improvement plans, G-95-055 (public) and PV-96-020 (private), sewer construction plans. On-site sewers are both public and private and existing. No new sewers are proposed.

All Sheets: Add the subdivision case number, S06-008, to the title block of each sheet. This number should be shown larger or bolder than any cross-reference numbers. No wastewater review fees will be charged for sheets where this is the only required revision.

All Sheets: Add the cross-reference numbers CD9-84-34N, G95-055 and PV-96-020 near title block of each sheet. These numbers should be shown smaller or less bold than the subdivision case number. No wastewater review fees will be charged for sheets where this is the only required revision.

Sheet 1: Add a General Note that states:

THE LANDSCAPING WITHIN ALL PUBLIC SEWER EASEMENTS SHOWN HEREON SHALL BE IN ACCORDANCE WITH THE PLANTING GUIDELINES OF PC/COT STANDARD DETAIL WWM A-4.

Sheet 1: Add a Permitting or General Note that states:

NO PERMITS FOR PERMANENT STRUCTURES (I.E., MASONRY WALLS, FENCES, ETC.) ON OR THROUGH THE PUBLIC SEWER EASEMENT WILL BE ISSUED WITHOUT SEPARATE WRITTEN CONSENT OF PIMA COUNTY WASTEWATER MANAGEMENT DEPARTMENT.

Sheet 2: Revise Keynote #6 so that:

The same 20 foot easement width that is recorded under docket 10125, Page 2351, is shown on the Keynote.

Sheet 3: Revise the site plan so that:

The sewer easement (docket 10125, Page 2351) that extends north to manhole #5025-08 (between G905 and C211) is clearly labeled.

Sheet 3: Revise this sheet to show:

The Keynote block added to describe the keynotes that are being used on this page.

Subject to the above, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the final plat . The required revision(s) may be shown on the Mylars.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.


If you have any questions regarding the above mentioned comments, please contact me at the telephone number shown under my signature on the first page of this letter

CC: Project File
03/02/2006 HEATHER THRALL ZONING REVIEW Denied CDRC TRANSMITTAL
TO: Development Services Department
Plans Coordination Office

FROM: Heather Thrall
Senior Planner

PROJECT: S06-008
Bear Canyon Condominiums, 9055 E. Catalina Highway
Final Plat

TRANSMITTAL DATE: March 2, 2006

DUE DATE: February 8, 2006

COMMENTS:

1. Section 4.1.7.1, LUC, permits a maximum of one year from the date of application to obtain approval of a final plat. If, at the end of that time, the final plat has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this tentative plat is February 7, 2007.

2. . This plan was reviewed in accordance with requirements of the Land Use Code (LUC), Development Standards (DS), American National Standard Institute (ANSI), and International Building Code 2003 (IBC). For reference, see DS 2-08 for pedestrian access, DS 2-09 for bicycle parking, 3-01 for sight visibility triangles and 3-05 for vehicular circulation requirements. Specifically, this project was reviewed for compliance with requirements of DS 2-03.6.0, which delineates information to be presented on the final plat.


3. Development Services has assigned case S06-008 to this project. Provide this case number in the lower right hand corner , near title block.

4. Per DS 2-03.6.1.K, provide annexation case C9-84-32 to this plat.

5. Per DS 2-03.6.2.G, provide note "This plat is subject to Board of Adjustment variance C10-95-44, unless expired or superseded by a subsequent application."

6. Per DS 2-03.6.2.J, provide note "This subdivision is subject to Ordinance No 5962, which established zoning in the Tanque Verde/Wrightstown Annexation Area."

7. Per DS 2-03.6.3.D, remove 2005 notation and replace with 2006 notation in Approval paragraph. Move Approval paragraph to be next to the Recording Data paragraph.

8. Per DS 2-03.6.D, add a period (.) before the "M" time reference in the Recording Data paragraph.

9. Provide a notation and dimensions for the space designated as "R" on pages 8-11, it appears to be a storage room option.

10. Per DS 2-03.6.6., the following protective covenants must be revised:
A) page 4, Sec.1.17 states that the ow3ner of the unit has the obligation to maintain the Limited Common Elements for which their unit is assigned. The limited common elements include patios, stairwells, landings and balconies. This statement implies that structural components, which are not owned by the condo holder, must be repaired by the condo owner - yet page 10 Sec. 5.3. states the Association has an easement over each unit for the purpose of maintaining, repairing, replacing or painting the Common Elements. The repair and maintenance of structural components should fall on the association for all limited common elements.

B) The intention on page 6, Sec. 1.29.6 is unclear. The owner of a unit is entitled to the right to use EITHER a garage unit AND one covered parking space. Clarify. Does the owner have the right to purchase a garage unit AND is entitled to one covered parking space? Keep in mind, parking requirements for a unit, and the amount to be provided, are based upon the approved development plan for this project, which states parking is to be provided based upon the number of bedrooms per unit. Please refer to the Development Plan Parking Requirement Notes to ensure all units get the amount of parking provided to them as recorded on the plan. Should a parking requirement call out 1.55 spaces, it should be rounded up to 2, and so forth. Note, further comments on this issue may be forthcoming.

C) Page 32, Section 11.16, talks about the possibilities of combining two or more condo units, and states that removing intervening walls or floors is permitted with the approval of the association. Please add a note that a permit must be issued by the City of Tucson prior to conducting any structural, plumbing, mechanical or electrical work to any units.

11. Please provide written documentation on how sections 4.1.9.1. and 4.1.9.2. of the LUC will be met with this proposed condominium conversion project.

12. Please note, depending upon the responses provided, further review comments may be forthcoming. Should you have any questions on this review, please contact me at Heather.Thrall@tucsonaz.gov or at 520-791-4541x1156.

If you have any questions about this transmittal, please call (520) 791-5608.
C:\planning\cdrc\finalplat\S06-008 bear canyon.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat, revised CC&R's.
03/03/2006 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

March 3, 2006

Rick Murillo
Stantec Consulting Inc.
201 North Bonita Avenue.
Tucson, AZ 85745

Subject: S06-008 Bear Canyon Condominiums Final Plat

Dear Rick:

Your submittal of January 10, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLUELINES MUST BE FOLDED

6 Copies Revised Final Plat (Real Estate, Wastewater, Addressing, Zoning, Engineering, DSD)

2 Copies Affidavits (Zoning, DSD)

2 Copies CC&R's (Zoning, DSD)



Should you have any questions, please call me at 791-5608 ext. 1179.

Sincerely,


Patricia Y. Gehlen
CDRC Manager