Plan Number: S05-252
Parcel: Unknown

Review Status: Completed

Review Details: RESUBMITTAL - MINOR SUBD REVIEW

Plan Number - S05-252
Review Name: RESUBMITTAL - MINOR SUBD REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/27/2006 MARILYN KALTHOFF START PLANS SUBMITTED Completed
11/21/2006 MICHAEL ST. PAUL ZONING REVIEW Denied CDRC TRANSMITTAL


FROM: Michael St.Paul, Planning Technician

PROJECT:S05-252
5020 East Fort Lowell Road
Minor Subdivision (Group B)


TRANSMITTAL: November 21, 2006


COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

Note: There were no response comments to the zoning review comments by this section.

1) An applicant has one (1) year from the date of submittal of a minor subdivision to obtain approval of a final plat that complies with zoning and other development requirements in effect at the time of application. This final plat must be approved and recorded on or before December 15, 2006.

2) This review is for a Group B Minor Subdivision (LUC Section 4.2.2.2) in the in the R-1 zone (LUC Section 2.3.4.2.A.1). The Development Designator is "G" for each individual lot and is subject to Section 3.5.7.1.E, .F, .G, and .H. The Perimeter Yard Indicator is AA for each lot (LUC Sections 3.2.3.1.B and 3.2.6.4). Please place a note stating that each individual lot must comply the requirements of the Land Use Code and Development Standards on the plat and any related Development Plan.

3) Please place the subdivision case (S05-252) number in the lower right corner of the plat and any other related sheets, such as the landscape plans, NPPO and grading plans (DS 2-03.6.1.K). I did not receive all the plans.

4) Please identify the conditions within the square mile area of the small projection map in the upper right corner. Identify the subdivisions plats by name with the book and page recording information. Also identify all major streets and major watercourses on the Final Plat (DS 2-03.6.1.D.2).

5) Clearly dimension and delineate the street and all parking spaces. Provide a copy of the DSMR. Provide the DSMR number, date of approval and conditions of approval on the plan.
11/21/2006 JIM EGAN COT NON-DSD FIRE Approved
11/21/2006 JOE LINVILLE LANDSCAPE REVIEW Denied 1) The site does have special development requirements, the Watercourse Amenities, Safety, and Habitat (WASH) ordinance and the Native Plant Preservation ordinance.
LUC 4.2.2.I

2) The native plant preservation application is denied. We find that the project may have a substantial impact on protected native plants. A native plant preservation plan is required.

3) The WASH ordinance is applicable to this site. A plant/habitat inventory and is required for any
development within 50' of the banks of the wash. Additional requirements apply for any resource area development. TCC 29-12. The review procedure is specified in TCC 23A-51.
Prepare the plans in accordance with DS 2-13.0.
11/22/2006 JOSE ORTIZ COT NON-DSD TRAFFIC Denied November 22, 2006
ACTIVITY NUMBER: S05-252
PROJECT NAME: 5000 Fort Lowell Place
PROJECT ADDRESS: 5000 Fort Lowell Place
PROJECT REVIEWER: Jose E. Ortiz PE, Traffic Engineer

Resubmittal Required: Traffic Engineering does not recommend approval of the Tentative Plat; therefore a revised Tentative Plat is required for re-submittal.

The following items must be revised or added to the plat.

1. Include a response letter with the next submittal that states how all comments have been addressed.

2. The proposed access road for this subdivision does not meet DS 3-01.0 figure 2. If this comment was addressed through a DSMR then place the DSMR case number on the plan sheets, and Traffic can confirm the approval of the modification request.


If you have any questions, I can be reached at 791-4259 x305 or Jose.Ortiz@tucsonaz.gov
11/27/2006 KAY MARKS PIMA COUNTY ADDRESSING Denied PIMA COUNTY ADDRESSING
201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S05-252 5000 FORT LOWELL PLACE/REVISED MINOR SUB REVIEW
DATE: NOVEMBER 27, 2006




The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:


1.) Add Road to Craycroft on Location Plan.

2.) Correct legal description on all Title Blocks per letter dated 02-08-06.

3.) Label approved interior street name.

4.) Correct scale on pg. 2.





jg
12/06/2006 GLENN HICKS COT NON-DSD PARKS & RECREATION Denied DATE: December 5, 2006

TO: Ferne Rodriguez, Development Services

FROM: Glenn Hicks
Parks and Recreation
791-4873 ext. 215
Glenn.Hicks@tucsonaz.gov

CC: Joseph Linville, Landscape Section, Development Services


SUBJECT: S05-252 5000 Fort Lowell Place:Minor Subdivision Review(10-27-06)

The site is adjacent to Alamo Wash Linear Park. To preserve the natural character of the park corridor, preservation of native vegetation is of utmost importantance. Therefore, staff is witholding approval until the Development Services Landscape Section approves the plans with respect to the requirements of the Watercourse Amenities, Safety, and Habitat (WASH) ordinance and the Native Plant Preservation ordinance.
LUC 4.2.2.I.

.
12/11/2006 FRODRIG2 COT NON-DSD REAL ESTATE Denied S05-252 5000 Fort Lowell Place: Resubmittal - Minor Subdivision Review - Concerning the "Public Drainage Easement Dkt. 8251, Pg. 808", area was conveyed, in fee, by Dkt./Pg. 8887/197 and 9179/1293.
12/13/2006 PAUL MACHADO ENGINEERING REVIEW Denied To: Patricia Gehlen DATE: December 13, 2006
CDRC/Zoning Manager

SUBJECT: 5020 E. Fort Lowell Road
Final Plat S05-252 (Second Review)
T14S, R15E, Section 14

RESUBMITTAL REQUIRED: Final Plat and Drainage Report.

The Final Plat (FP) and Drainage Report (DR) cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Final Plat:

1. Please include a response letter to the comments along with the corrected copies of the FP.
2. A separate grading plan is required for this subdivision.
3. Provide 5' sidewalk along the entire length of the properties frontage per D.S. 3-01.3.3.A.
4. Per your response letter pertaining to the previous submittal comments 2, 3 and 4, a DSMR was approved to satisfy those comments. However, a copy of the letter approving DSMR must be included in the CDRC submittal.
5. The proposed street width does not meet development standards per D.S. 3-01.0. A Development Standard Modification Request (DSMR) will be necessary for the proposed street width.
6. Subdivisions over an acre equal to 3 units but not greater than 6 units are required to provide 2-year threshold retention.
7. Please show the proposed roof drainage patterns, 100% of the 10-year flow must be conveyed under the sidewalks including any other site drainage as well. Please provide supporting calculations to demonstrate compliance with D.S. 3-01.4.4.
8. Show detention/retention areas in a surveyable and readily retraceable manner per D.S. 2-03.6.4.I.
9. Show the subdivision case number (S05-252) in the lower right corner of the plat next to the title block per D.S. 2-02.6.1.K.
10. Submit the Subdivision Improvement Assurances for review. The following items are required in the assurance package if a Third Party Trust Agreement will be used:
· Title Report
· Special Warranty Deed
· Trust Agreement
· Amendment to Trust
· Agreement to Construct
Submit the above documents containing original signatures, copies of the documents and signatures will not be forwarded to the City of Tucson attorney for review. The final plat cannot be recorded prior to the acceptance of the assurances.
11. The title block of the plat must match the Subdivision Assurances verbatim.
12. Please re-label all common areas that may be used in a dual and/or single use capacity per D.S. 2-03.6.4.C. For example, a Ret./Det. Basin may also be used as a recreation facility or only as a drainage facility or drainage channel and this must be reflected on the Final Plat. A key note explaining the labels could be used in conjunction with the labels, ie.:
Common Area "A" - Streets
Common Area "B" - Drainage/Recreation Facilities
Common Area "C" - Recreation Facilities
Common Area "D" - Drainage Facilities
Common Area "E" - Landscaping
If the retention criterion has not been waived by a DSMR, the common area designations will have to be modified to reflect this comment.
13. Show sight visibility triangles per D.S. 2-02.2.1.10. The SVT's are not per City of Tucson standards and do not measure to the proper distances. Also it appears the edge of pavement is actually wider than what is shown on the plans.
14. Show a 1' no access esmt. along the East property lot lines per D.S. 2-03.6.3.A. The response letter indicates that the 1' NAE will be included in the 11' undeveloped undisturbed area, however the reference to 1' NAE must be called out on the plans.
15. At least one corner of the subdivision will be tied by course and distance to a section corner, a quarter corner, or an established……….per D.S. 2-03.6.5.A. Per previous comment.
16. Show the distance and bearing between all monuments used…per D.S. 2-03.6.4.C.5.
17. Complete "Basis of Elevation" per D.S. 2-03.6.5.C. The Bench Mark shall be based on City of Tucson Datum, including City Field Book and page number per D.S. 2-02.2.1.23. Per previous comment.
18. Please submit a copy of the subdivision boundary closure calculations. Per previous comment.
19. The 100-year floodplain limits and EHS shall be shown in a suveyable manner per D.S. 2-03.6.4.E and F.
20. Add note: "Depress all landscaped areas 6" maximum for water harvesting".

Drainage Report:
1. Please include a response letter to the comments along with the corrected copies of the DR.
2. The DR states that only 1 house will be constructed on the site. If not, a future condition hydrology data sheet must be included in the DR.
3. A TSMS node on the Tucson Department of Transportation map at Ft. Lowell Rd. and the Alamo Wash is listed as having a Q100 of 6307 cfs. The EHS is for this wash is approximately 77 +/- feet. Address as required.
4. Subdivisions over an acre equal to 3 units but not greater than 6 units are required to provide 2-year threshold retention. Per previous comment.
5. Show all details of and cross sections of the proposed basin. Per previous comment.
6. If applicable, add the basin(s) maintenance responsibility note and checklist per S.M.D.D.F.M. 2.3.1.6 C 1 and 2 to the DR. Per previous comment.
7. Please show the proposed roof drainage patterns, 100% of the 10-year flow must be conveyed under the sidewalks including any other site drainage as well. Please provide supporting calculations to demonstrate compliance with D.S. 3-01.4.4.

If you have any questions, I can be reached at 791-5550 x1193 or Paul.Machado@tucsonaz.gov
Paul P. Machado
Senior Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 791-5550 x1193 office
(520) 879-8010 fax
C:/5020 E. Fort Lowell Rd. FP 2
12/14/2006 FRODRIG2 PIMA COUNTY WASTEWATER Denied December 14, 2006

To: Lloyd Rogers, Rogers Civil Engineering

Thru: Patricia Gehlen, CDRC Manager
City of Tucson Development Services Department

From: Chandubhai C. Patel, P.E.
Pima County Development Services Department
Development Review Division (Wastewater)

Subject: 5000 Ft. Lowell Place, Lots 1-5
Final Plat – 2nd Submittal, S05-252

The drawings for the proposed final plat for the above-referenced project has been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.



Please show how you intend to provide sewer service to this development. This information with all the pertinent General Notes, Permitting Notes, required easements, sewer size, slopes, inverts, connection to the public sewer, information about the connection point, types of proposed sewers ( public or private), etc. should be shown on the 3rd Sheet; and modify the title Block of this 3rd sheet so that it resembles the title blocks on the 1st and 2nd sheets. This way we will have the information that we need shown on a Development Plan without having you to submit a formal development plan for this project.

2. SHEET 1. The language in the DEDICATION block will need to be modified a little once we review and approve the sewer system serving this development that will be shown on the 3rd sheet.

3. Pima County Code Title 13.20.030.A.2 requires that a wastewater review fee be paid for each submittal of the Final Plat. The next submittal of this Final Plat will be the third submittal. A check for the review fee of this submittal in the amount of $78.00 (made out to PIMA COUNTY TREASURER) must accompany the revised set of bluelines and a response letter addressing these comments.


If you have any questions regarding the above comments, please do not hesitate to contact me.

Sincerely,

Chandubhai C. Patel, P.E.
Phone: 520-740-6563

CC: Project File
12/19/2006 PATRICIA GEHLEN ZONING-RECORDATION REVIEW Needs Review
12/19/2006 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

December 19, 2006

Lloyd W. Rogers P.E.
Rogers Civil Engineering
1765 West Klamath Drive
Tucson, Arizona 85704

Subject: S05-252 5000 Fort Lowell Place Minor Subdivision

Dear Lloyd:

Your submittal of October 27, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

9 Copies Revised Final Plat (Landscape, Zoning, Traffic, Addressing, Parks and Recreation, Real Estate, Engineering, Wastewater, DSD)

2 Copies Drainage Report (Engineering, DSD)

2 Copies Native Plant Preservation Plans (Landscape, DSD)

PRIOR TO RESUBMITTAL OF THIS TENTATIVE PLAT, A WRITTEN EXTENTION REQUEST MUST BE SUBMITTED TO AND APPROVED BY THE CDRC OFFICE.



Should you have any questions, please call me at 791-5608 extension 1179.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 888-8571