Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Plan Number: S05-250
Parcel: Unknown

Address: Unknown

Review Status: Completed

Review Details: RESUBMITTAL - MINOR SUBD REVIEW

Plan Number - S05-250
Review Name: RESUBMITTAL - MINOR SUBD REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/03/2007 JOE LINVILLE LANDSCAPE REVIEW Approv-Cond Ensure that the mylars sumitted for approval include a corrected mitigation summary on the native plant preservation
plan. Indicate that 5 of the trees are viable as shown on the plan and the inventory list.

NO RESUBMITTAL REQUIRED
01/05/2007 FRODRIG2 PIMA COUNTY WASTEWATER Denied January 8, 2007

To: Kent Delph, Delph Engineering

Thru: Patricia Gehlen, CDRC Project Manager
City of Tucson Development Services Department

____________________________________
From: Michael J. Harrington (520-740-6579), representing the Pima County
Departments of Wastewater Management and Environmental Quality

Subject: Colonial Solana
Lots 1-4
Final Plat - 1st Submittal
S05-250

The proposed final plat for the above-referenced project has been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


All Sheets: Add the subdivision case number, S05-250, to the title block of each sheet. This number should be shown larger or bolder than any cross reference numbers. No wastewater review fees will be charged for sheets where this is the only required revision.

Sheet 1: In the Legend block, LOT LINES and NEW EASEMENT LINE AS NOTED, as shown in the Legend and on the plans, are very similar, which makes the easements boundary look like lot lines. Consider using a dashed or shaded linetype for the easement lines.

Sheet 1: The label for the INGRESS / EGRESS, DRAINAGE, UTILITY AND PARKING EASMENT is not specific enough to make it clear what the easement is for and who has legal access. We would prefer wording that is more specific, something like:

PUBLIC UTILITY, PRIVATE ACCESS, PARKING AND DRAINAGE EASEMENT, BY THIS PLAT

Also, we would like to see this label duplicated on Lot 3 or Lot 4.

Sheet 1: In the DEDICATION block, 2nd paragraph, 1st sentence. Although the City Of Tucson may accept that the easement be granted as an easement to the PUBLIC, Pima County prefers that you GRANT to THE CITY OF TUCSON, PIMA COUNTY AND ALL UTILITY COMPANIES…

Sheet 1: In the DEDICATION block, 2nd paragraph, 3rd sentence. Revise this sentence so that PRIVATE SEWERS are included in the list of elements that the Association will accept responsibility for.

This office will require a revised set of bluelines, and a response letter, addressing these comments. Additional comments may be made during the review of these documents.

Pima County Code Title 13.20.030.A.2 requires that a wastewater review fee be paid for each submittal of the final plat. The fee for the first submittal is $166 plus $50 per sheet. For the second submittal, the review fee is $50 per sheet. For all subsequent submittals, the review fee is $39 per sheet.

The next submittal of this project will be the second (2nd) submittal. A check for the review fee of this submittal in the amount of $50.00 (made out to PIMA COUNTY TREASURER) must accompany the revised set of bluelines and response letter.

If the number of sheets changes, please adjust the review fee accordingly.


If you have any questions regarding the above mentioned comments, please contact me at the telephone number shown under my signature on the first page of this letter

CC: Project File
01/05/2007 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Approved SUBJECT: COLONIAL SOLANA
S05-250

Tucson Electric Power Company has reviewed and approved the minor
subdivision submitted December 26, 2006.

In order to apply for electric service, call the New Construction
Department at (520) 918-8300. Submit a final set of plans including
approved site, offsite and electrical load plans. Include a CD with the
AutoCAD version of the plans. If easements are required, they will be
secured by separate instrument. Your final plans should be sent to:

Mike Kaiser

Design/Build DB 102

Tucson Electric Power
Company

P. O. Box 711

Tucson, AZ 85702



Please call me at (520) 917-8745, should you have any questions


Liza Castillo, Right of Way Agent
Land Management
Tucson Electric Power Co.
Unisource Energy Gas & Unisource Energy Electric
PH: (520) 917-8745
lcastillo@tep.com <mailto:lcastillo@tep.com>
01/08/2007 JCLARK3 ENV SVCS REVIEW Approved Origionally approved 1/03/06. T turnaround should be off set to one side to permit a better turnaround. Will still work but requires an additional buckup.
01/10/2007 GLENN HICKS COT NON-DSD PARKS & RECREATION Approved DATE: January 8, 2007

TO: Ferne Rodriguez, Development Services

FROM: Glenn Hicks
Parks and Recreation
791-4873 ext. 215
Glenn.Hicks@tucsonaz.gov

CC:


SUBJECT: S05-250 Colonial Solana: Minor Subdivision Review(12-26-06)


Staff has no comments.
01/10/2007 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Approved DEPARTMENT OF URBAN PLANNING & DESIGN

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

S05-250 Colonial Solana 01/10/07

() Tentative Plat
() Development Plan
() Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
(XXXX) Other – Site Plan, Record of Survey, Preservation
& Grading Plan

CROSS REFERENCE:

NEIGHBORHOOD PLAN: El Encanto/Colonia Solana

GATEWAY/SCENIC ROUTE:

COMMENTS DUE BY: 01/22/07

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

() No Annexation or Rezoning Conditions, Not an RCP - No Comment
(XXXX) Proposal Complies with Annexation or Rezoning Conditions
() RCP Proposal Complies With Plan Policies
() See Additional Comments Attached
() No Additional Comments - Complies With Planning Comments Submitted on:
() Resubmittal Required:
() Tentative Plat
() Development Plan
() Landscape Plan
() Other

REVIEWER: D.R. Corral 791-4505 DATE: 01/09/07
01/11/2007 FRODRIG2 COT NON-DSD REAL ESTATE Denied S05-250 Colonial Solana: Resubmittal - Minor Subdivision Review - Request "Dedication" block contain language that dedicates the 15' along Broadway Blvd. for right-of-way purposes.
01/18/2007 ED ABRIGO PIMA COUNTY ASSESSOR Denied Office of the Pima County Assessor


115 N. Church Ave.


Tucson, Arizona 85701



BILL STAPLES

ASSESSOR










TO: CDRC Office

Subdivision Review

City of Tucson (FAX# 791-5559)



FROM: Gary Ault, Mapping Supervisor

Pima County Assessor's Office

Mapping Department



DATE: January 17, 2007





RE: Assessor's Review and Comments Regarding Final Plat

S05-250 COLONIAL SOLANA T141416





* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *



X Plat meets Assessor's Office requirements.(SEE COMMENTS)

_______ Plat does not meet Assessor's Office requirements.





COMMENTS: PLEASE MAKE THE FOLLOWING ADJUSTMENTS BEFORE RECORDING:

1. ADD INFO. FOR THE ADJACENT AREAS (EITHER UNSUDIVIDED OR
APPROPRIATE M&P).

2. IF A PORTION OF LOT 12 IS TO BE AN EASEMENT THE LINES SHOULD
BE DASHED.



THANK YOU FOR YOUR SUBMITTAL. IF YOU HAVE ANY QUESTIONS PLEASE CALL
ROSANNA WERNER AT 740-4390



NOTE: THE ASSESSOR'S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS
TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN
THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING
THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK
YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.













ROSANNA WERNER
01/19/2007 KAY MARKS PIMA COUNTY ADDRESSING Denied 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S05-250 COLONIAL SOLANA/MINOR SUB REVIEW
DATE: 1/18/07



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:


Fill in File number.

On Title Block change Solona to Solana and T-15-S to T-14-S.

Spell out Boulevard of Broadway Blvd per letter dated 1/10/06.
01/23/2007 DAVID RIVERA ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: David Rivera
Principal Planner

PROJECT: S05-250
Colonial Solana, Lots 1-4
Minor Subdivision

TRANSMITTAL: 02/03/06

DUE DATE: 01/19/06

COMMENTS:

1. Section 4.1.7.1, LUC, permits a maximum of one year from the date of application to obtain approval of a tentative plat. If, at the end of that time, the tentative plat has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this tentative plat is December 19, 2007.

2. This plan has been reviewed for compliance with Development standards 2-03, final plat format and content and additional development standards, 2-08, 3-01 and any applicable LUC development criteria for the site development plan.

3. Revise the existing subdivision name in the brief legal description from "Colinia Solona' to "COLONIA SOLANA"

(A portion of the previous comment) A title block with the following information is to be provided approximately in the lower right corner of the first page of the plat.

a. A brief legal description and a statement as to whether the project is a resubdivision are to be provided. On re-subdivisions, provide the recording information of the existing subdivision plat.
DS 2-03.2.1.G.1-.3

4. The subdivision case number has been listed on all plan sheets except the final plat sheet. Please list the case number as requested.

(Previous Comment) This project has been assigned the subdivision case number S05-250. Please list the case number in the lower right corner next to the title block of all plan sheets.
DS2-03.2.2.B.1

5. Under keynote 7 on sheet 2 of 3 the word 'refuse' should be revised to "REFUGE".

(A portion of the Previous comment) Also revise the word "refuse" in keynote 7 to "Refuge". DS 2-03.2.2.B.2

6. Please clarify if the building square footage includes the garage and if the vehicular use area includes both the street area and driveway and pedestrian areas. LUC 3.2.9.2

(Previous Comment) Please ensure that the under the individual lot table the driveway area is included for the lot coverage calculation.
DS 2-03.2.4.I

7. Due to the expiration of the plat and extension allowed with conditions that all new code or LUC requirements are to be met and incorporated into the plat. Sidewalks on both sides of the street are required per a new Development Services Policy. The approved DSMR never included the request to modify the sidewalks. Therefore the sidewalks must be provided. Draw, label and dimension the required sidewalks.

(Previous Comment) Sidewalks are required as part of new development of all properties. All new subdivisions and applications for building permits shall provide five (5) foot wide sidewalks along the entire length of street frontage, whether public or private, of the property in question. The sidewalk requirements also apply to expansions in floor area, site area, or vehicular use area of twenty-five (25) percent or more. Sidewalks are not required in the following circumstances.

8. Add a note that states that development on this project is subject to compliance with LUC section 3.5.7.1.E, .F, .G, and .H

FINAL PLAT COMMENTS

1. List the subdivision case number S05-250 in the lower right corner of the final plat sheet. DS 2-03.6.1.K

2. For consistency, review and revise, as needed the gross site area on both the site/development plan and the final plat. I acknowledge that the site/development plan does not include the dedication of right-of-way but the site/development plan should reflect the future dedication. If needed list the existing and future site area. DS 2-03.6.2.A

3. For consistency, review and revise, as needed the total miles of private street on both the site/development plan and the final plat. I acknowledge that the site/development plan does not include the dedication of right-of-way but the site/development plan should reflect the future dedication. If needed list the existing and future total private street miles. (It may be best to list the future information for both the site area and total private street miles

4. Revise the following items under the Approval and Recordation text blocks: revise the year from 2006 to 2007. Add the ". M" after the word at _____ in the Recordation text block. DS 2-03.6.3.D
5. Label the name of the proposed private street. DS 2-03.6.4.A

6. If applicable, show, label, and dimension no vehicular access easements. DS 2-03.6.4.H

7. The title sheet of the CC&R's indicates the date of 2006. Please revise to 2007. Revise all dates not representing 2007. Also under the Recitals of the CC&R's Common Areas "A, B, C" are listed but in the title block common areas are not listed in the title blocks or drawn and labeled on the plat or site/development plan. There does not appear to be any common areas within this subdivision proposal. All references to common areas must be removed from the CC&R's if no common areas are proposed. DS 2-03.6.6

If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.

DGR C:\planning\cdrc\tentativeplat\S05250fp.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site/development plan and revised final plat, CC&R's and additional requested documents.
01/29/2007 TOM MARTINEZ OTHER AGENCIES AZ DEPT TRANSPORTATION Passed
02/01/2007 FRODRIG2 OTHER AGENCIES PIMA ASSN OF GOVTS Passed
02/06/2007 PATRICIA GILBERT ENGINEERING REVIEW Denied TO: Patricia Gehlen; CDRC Coordinator DATE: January 25, 2006

SUBJECT: Engineering review of the Colonial Solana Minor Subdivision. The activity number is S05-250.

SUMMARY: The Zoning, Grading and Improvement Plan and Drainage Statement was received by Engineering on December 20, 2005. Engineering has reviewed the received items and does not recommend approval of the Zoning, Grading and Improvement Plan.

SUBMIT: FINAL PLAT

RESUBMITTAL REQUIRED: ZONING, GRADING AND IMPROVEMENT PLAN, FINAL PLAT

APPROVED: DRAINAGE STATEMENT

GENERAL COMMENTS

1. Please include the Assurance Package with the Final Plat submittal. The final plat cannot be scheduled for Mayor and Council consideration until the financial assurances are approved. The complete assurances package must include a copy of the original trust, the original amendment to trust with exhibit A, the original agreement to construct with exhibit B, a copy of the warranty deed, a current title report and a location map on an 8 ½ x 11 sheet. DS Sec.2-03.7.1.G

2. A Grading Plan and Permit will be required. A separate grading review will be required. When this review of the minor subdivision is near approval this office recommends formally submitting the grading plan for review. Submit two copies of the grading plan and stormwater pollution prevention plan.

The next submittal must address the following items:

FINAL PLAT COMMENTS:

1. Place the subdivision case number in the lower right hand corner of the first sheet. DS 2-03.2.2.B.1.

The above comment is from the first review and has not been completely addressed. Provide the subdivision case number on sheet one of the final plat.

2. Revise the Final Plat Standard paragraphs on sheet one so that they are listed in the following order for better understanding and clarity DS Sec.2-03.6.3:

1. Dedication Paragraph
2. Beneficiary Block Paragraph
3. Acknowledgement Paragraph
4. Approval Paragraph
5. Recordation Data Block Paragraph
6. Assurance Block
7. Certification of Survey

3. There is an easement (docket 593 book 174) in the title report that is not shown on the final plat. Is the intent to abandon the easement? Please clarify. Show the easement on the plat or indicate on the plat the easement is to be abandoned. D.S. 2-03. 2.2.3.C.

4. Indicate on the plat (sheet one of one) if the ingress/egress, drainage, utility and parking easement is public or private. D.S. 2-03. 2.2.4.J.

5. In the ASSURANCE block revise the verbiage below the signature line to read, "City of Tucson Development Services Department Engineering Administrator." DS 2-03.6.3.E.

6. If applicable show no-vehicular access easements on the plat view. DS 2-03.6.4.H.

7. Corner tie information is to be provided on the plat. At least one corner of the subdivision must be tied by course and distance to a section corner or a quarter section corner. The plat must include a description of that corner marker and an indication of how the bearings were determined. Provide the corner tie recordation information on the plat. DS 2-03.6.5.A.

8. General note number 16 provides a DSMR case number that is an actual Development Standard number. In the Permit's Plus tracking system there is a case number DS06-11 with a location of Country Club and Broadway Blvd. Was the intent to provide DS06-11 as the case number? Clarify.

9. In addition to the above comment please refer to Zoning's Comment 7. The approved DSMR did not request to eliminate the 5' sidewalks on both sides of the street therefore sidewalks must be shown on the site plan (see site plan comment xxx below). Adjust the plat view accordingly.


ZONING, GRADING AND IMPROVEMENT PLAN COMMENTS (SHEET 2 and 3):


1. General note number 18 provides a DSMR case number that is an actual Development Standard number. In the Permit's Plus tracking system there is a case number DS06-11 with a location of Country Club and Broadway Blvd. Was the intent to provide DS06-11 as the case number? Clarify.

2. On sheet 3, the grading plan, spell future correctly on the 80' future ROW dimension.

3. Remove from the title block the verbiage, "& Common Easement."

4. The curve and line table on sheet 2 are missing some data lines. Revise the plan view to show on each table the missing data, (C3, L15 and L16).

5. Sidewalks are required on streets where new development occurs per a new Development Services policy. Draw, label and dimension the required 5' sidewalk on both sides of the private street.

6. There are two 3/1 cross sections on sheet 3. The cross section between lot 3 and 4 appears to be labeled incorrectly. Clarify and/or revise.

7. Be advised a separate grading review will be required and additional comments could be forthcoming.
02/07/2007 PATRICIA GEHLEN ZONING-RECORDATION REVIEW Needs Review
02/07/2007 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

February 7, 2007

Kent Delph
Delph Engineering
1660 North Alvernon Way
Tucson, Arizona 85712

Subject: S05-250 Colonial Solana Final Plat (Minor Subdivision)

Dear Kent:

Your submittal of December 26, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

7 Copies Revised Final Plat and Site/Grading Plan (Wastewater, Real Estate, Assessor, Addressing, Zoning Engineering, DSD)

2 Copies CC&R's (Zoning, DSD)


Should you have any questions, please call me at 791-5608 extension 1179.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 326-7508
fpresubmittal
12/20/2006 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
12/26/2006 JOSE ORTIZ COT NON-DSD TRAFFIC Approved
12/27/2006 JIM EGAN COT NON-DSD FIRE Approved