Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - MINOR SUBD REVIEW
Plan Number - S05-246
Review Name: RESUBMITTAL - MINOR SUBD REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/01/2006 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 08/29/2006 | KAY MARKS | PIMA COUNTY | ADDRESSING | Denied | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 KAY MARKS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: KAY MARKS, ADDRESSING OFFICIAL SUBJECT: S05-246 BARRIO OCHOA/REVISED MINOR SUB REVIEW DATE: August 28, 2006 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval: Location Map Scale is not correct. Per letters dated 01-04-06 and 04-03-06. Delete all dockets and pages of adjacent parcels. If this will not be a recorded subdivision, the recorded deeds with legal descriptions of the lots will need to be provided in order to receive addresses. jg |
| 09/20/2006 | LOREN MAKUS | ENGINEERING | REVIEW | Denied | DATE: September 20, 2006 To: Patricia Gehlen CDRC/Zoning Manager FROM: Loren Makus, EIT Engineering Division SUBJECT: Barrio Ochoa Plat S05-246 (Third Review) T14S, R13E, Section 24 RESUBMITTAL REQUIRED: Revised Plat and Drainage Report The Plat and Drainage Report have been reviewed by the Engineering Division and we do not recommend approval at this time. Note that a grading permit and Stormwater Pollution Prevention Plan will be required. Issues such as differential grading and proposed finish floor elevations will be addressed with the grading plan review. The following comments must be addressed. Plat: 1. The common area dedicated to the retention basin must be labelled as "Retention Basin" or "Retention Basin and Drainage" on the plat and in the title block. This is at the request of Mayor and Council. 2. Provide design details for the basin in the supplemental plans. Provide a separate common area for the basin. Drainage Report: 3. Revise the retention volume calculation in the drainage report addendum. Use the 2-year runoff coefficients for both the existing and developed conditions. Show the calculations used to determing the retention volume. Provide a complete drainage report incorporating all of the addenda. If you have any questions, I can be reached at 791-5550 x1161 or loren.makus@tucsonaz.gov. Loren Makus, EIT Senior Engineering Associate |
| 09/22/2006 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES September 22, 2006 Daniel White Physical Resources Engineering, Inc. P.O. Box 36985 Tucson, AZ 85740 Subject: S05-246 Barrio Ochoa Minor Subdivison Dear Dan Your submittal of August 2, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLUELINES MUST BE FOLDED 3 Copies Revised Final Plat (Addressing, Engineering, DSD) 2 Copies Revised Drainage Report (Engineering DSD) Should you have any questions, please call me at 791-5608 ext. 1179. Sincerely, Patricia Y. Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 690-1769 |
| 09/22/2006 | PATRICIA GEHLEN | ZONING-RECORDATION | REVIEW | Needs Review |