Plan Review Detail
Review Status: Completed
Review Details: RECORD OF SURVEY REVIEW
Plan Number - S05-224
Review Name: RECORD OF SURVEY REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/06/2006 | ROGER HOWLETT | COT NON-DSD | COMMUNITY PLANNING | Approved | DEPARTMENT OF URBAN PLANNING & DESIGN Regarding SUBJECT: Community Design Review Committee Application CASE NUMBER: CASE NAME: DATE SENT S05-224 Riverview Acres 01/05/06 () Tentative Plat () Development Plan () Landscape Plan () Revised Plan/Plat () Board of Adjustment (XXXX) Other – Record of Survey CROSS REFERENCE: NEIGHBORHOOD PLAN: Santa Cruz GATEWAY/SCENIC ROUTE: COMMENTS DUE BY: 1/05/06 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: (XXXX) No Annexation or Rezoning Conditions, Not an RCP - No Comment () Proposal Complies with Annexation or Rezoning Conditions () RCP Proposal Complies With Plan Policies () See Additional Comments Attached () No Additional Comments - Complies With Planning Comments Submitted on: () Resubmittal Required: () Tentative Plat () Development Plan () Landscape Plan () Other REVIEWER: D. Estolano 791-4505 DATE: 1/05/06 |
| 01/12/2006 | FRODRIG2 | COT NON-DSD | REAL ESTATE | Approved | S05-224; No objection except to note that this should be a subdivision. This review did not include a review of the legal descriptions or an endorsement of their use to describe the six parcels. |
| 01/14/2006 | HEATHER THRALL | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Heather Thrall Senior Planner PROJECT: S05-224 Riverview Acres Record of Survey TRANSMITTAL: January 13, 2006 DUE DATE: December 29, 2005 COMMENTS: 1. An applicant has one (1) year from the date of submittal to obtain approval of a record of survey that complies with zoning and other development requirements in effect at the time of application. This record of survey must be approved and recorded on or before November 29, 2006. 2. This project was reviewed in accordance with requirements of the Land Use Code (LUC), Development Standard (DS), American National Standard Institute (ANSI) and International Building Code 2003 (IBC). 3. Per DS 2-03.11.7.I, symbols for what are assumed as light poles (lp), power poles (pp) and water mains (wm) are shown on the submitted record of survey. Please add these symbols and their respective labels to the legend. 4. Per DS 2-03.11.8.B.1, Development Services has assigned the subdivision case number "S05-224" to this project. Please add this notation, near the title block. 5. The submitted drawing indicates the subject project is currently comprised of three (3) parcels, ending in parcel identification numbers 115A, B and C. Staff was unable to confirm this information, finding the current project and legal description refers to one parcel, 115-17-1920. For clarification, please provide official information on the stated three parcel configuration, or if incorrect, please revise the drawing to show the current configuration as located under Pima County Assessor's records. 6. Under the Notes, it is indicated "blanket easements" for utilities are involved with this property. Please show these easements graphically on the drawing, per DS2-03.11.12.A. 7. Per DS 2-03.11.12.E, please show the location of all proposed driveways. 8. As a residence exists on the subject site, to be contained within proposed parcel 4, provide the total proposed lot coverage of lot 4 (driveways and buildings), proposed building setbacks and exterior building wall heights facing the proposed north and west lot lines. Per the LUC, the maximum lot coverage is 70% for a single family residence in the R-2 zone, and minimum setbacks are the greater of six (6) feet or 2/3 rds the height of the exterior building wall. 9. Staff acknowledges the notice from the Zoning Administrator advising the existing residence is legal nonconforming for existing setbacks to the existing/proposed south lot line. 10. Should you have any questions on this review, please contact me via email at Heather.Thrall@tucsonaz.gov or at 791-4541x1156. If you have any questions about this transmittal, please call (520) 791-5608. C:\planning\cdrc\record.of.survey\S05-224.Riverview.Acres.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised record of survey and additional requested documents. |
| 01/25/2006 | MARILYN KALTHOFF | PIMA COUNTY | WASTEWATER | Approv-Cond | January 24, 2006 To: Daniel White, Physical Resource Engineering Thru: Patricia Gehlen, CDRC Project Manager City of Tucson Development Services Department ____________________________________ From: Tim Rowe, P.E. (520-740-6563), representing the Pima County Departments of Wastewater Management and Environmental Quality Subject: Riverview Acres, Lots 1-6 Record of Survey - 1st Submittal S05-224 The proposed Record of Survey for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. 1. This project will be tributary to the Roger Road Wastewater Treatment Facility via the Northwest Outfall Interceptor.. Sufficient conveyance and treatment capacity is known to exist in the downstream public sewerage system for this small project, and a formal capacity response letter from the PCWMD will not be required for this small project. 2. This project will not qualify for any connection fee discounts pursuant to Pima County Ordinance 2005-112. 3. All Sheets: Add the case number, S05-224, to the title block of each sheet. This number should be shown larger or bolder than any cross reference numbers. No wastewater review fees will be charged for sheets where this is the only required revision. 4. Nice Job! You've presented the information about how this project will be sewered very well. Now we just need to do a bit of clean-up, so that the final Record of Survey does not show the sewer information. The Record of Survey does not need to show the utilities. The following comments are meant to assist you in cleaning up this Record of Record. 5. Delete Notes 8, 9 & 10. 6. Delete the proposed sewer connections to each lot. 7. Delete the public sewer lines and the related information about those sewer lines shown in the Riverview Blvd. and Yavapai Street rights of way. 8. Subject to the above, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the Record of Survey. The required revision(s) may be shown on the Mylars. Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality. Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution. If you have any questions regarding the above mentioned comments, please contact me at the telephone number shown under my signature on the first page of this letter CC: Project File |
| 02/06/2006 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Passed | |
| 02/08/2006 | PATRICIA GEHLEN | ZONING-RECORDATION | REVIEW | Needs Review | |
| 02/08/2006 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES February 8, 2006 Daniel White Physical Resource Engineering, Inc. P.O. Box 36985 Tucson, AZ 85740 Subject: S05-224 Riverview Acres Record of Survey Dear Dan: Your submittal of November 30, 2005, for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLUELINES MUST BE FOLDED 4 Copies Revised Record of Survey (Engineering, Zoning, Wastewater, DSD), Should you have any questions, please call me at 791-5608, ext 1179. Sincerely, Patricia Y. Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 690-1769 |
| 11/30/2005 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 12/01/2005 | JIM EGAN | COT NON-DSD | FIRE | Approved | The plan is approved December 01, 2005. |
| 12/05/2005 | JCLARK3 | ENV SVCS | REVIEW | Approved | * No known landfill with in 1000 feet of this development. * Each lot boarders on a dedicated street. Approved for APC curb side service if residential homes. * APC's are to be placed and removed from the curb side collection area on the day of service. |
| 12/06/2005 | TOM MARTINEZ | OTHER AGENCIES | AZ DEPT TRANSPORTATION | Approved | NO COMMENT S05-224 PHYSICAL RESOURCE ENGINEERING, INC. RIVERVIEW ACRES ********************************************************************* Confidentiality and Nondisclosure Notice: This email transmission and any attachments are intended for use by the person(s)/entity(ies) named above and may contain confidential/privileged information. Any unauthorized use, disclosure or distribution is strictly prohibited. If you are not the intended recipient, please contact the sender by e-mail, and delete or destroy all copies plus attachments. Neither the State nor the Arizona Department of Transportation and/or its employees shall be liable for violations of law, or damages resulting from your dissemination or use of this email transmission if you are not the intended recipient. ********************************************************************* |
| 12/09/2005 | KAY MARKS | PIMA COUNTY | ADDRESSING | Approved | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 KAY MARKS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: KAY MARKS, ADDRESSING OFFICIAL SUBJECT: S05-224 RIVERVIEW ACRES/RECORD OF SURVEY REVIEW DATE: 12/08/05 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project. NOTE: ON FINAL MYLAR: Change H. Silver Cloud Estates 47/24 to 47/14 on Location Map. 2.) Recorded deeds with legal descriptions will be required in order to assign addresses. ***The Pima County Addressing Section can use digital CAD drawing files when submitted with your final plat Mylar. These CAD files can be submitted through the Pima County Subdivision Coordinator. The digital CAD drawing files expedite the addressing and permitting processes when we are able to insert this digital data into the County’s Geographic Information System. Your support is greatly appreciated.*** |
| 12/22/2005 | JOE LINVILLE | LANDSCAPE | REVIEW | Approved | |
| 12/22/2005 | GLENN HICKS | COT NON-DSD | PARKS & RECREATION | Approved | DATE: December 21, 2005 TO: Ferne Rodriguez, Development Services FROM: Glenn Hicks Parks and Recreation 791-4873 ext. 215 Glenn.Hicks@tucsonaz.gov SUBJECT: S05-224 Riverview Acres: Record of Survey Review Staff has no comments. |
| 12/23/2005 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Approved | SUBJECT: RIVERVIEW ACRES S05-22 Tucson Electric Power Company has reviewed and approved the Record of Survey review submitted November 30, 2005. It appears that there are no conflicts with the existing facilities within the boundaries of this proposed development. In order to apply for electric service, call the New Construction Department at (520) 770-2062. Submit a final set of plans including approved site, offsite and electrical load plans. Include a CD with the AutoCAD version of the plans. If easements are required, they will be secured by separate instrument. Your final plans should be sent to: Mike Kaiser Design/Build - DB 102 Tucson Electric Power Company P. O. Box 711 Tucson, AZ 85702 Please call me at (520) 917-8745, should you have any questions. Liza Castillo Right of Way Agent Land Management Tucson Electric Power Co. (520) 917-8745 lcastillo@tep.com |
| 12/23/2005 | FRODRIG2 | OTHER AGENCIES | PIMA ASSN OF GOVTS | Approved | Estimated daily traffic in 24 hr period - 57 |
| 12/29/2005 | LOREN MAKUS | ENGINEERING | REVIEW | Denied | S05-224 Riverview Acres Engineering Review Comments Loren Makus - Reviewer 29 December 2005 Resubmittals required: Revised Record of Survey Engineering Division has reviewed the proposed Record of Survey/Land split proposal, and approval is not recommended at this time. Please address the following comments prior to resubmittal: 1. Per the draft Development Standard Section 11.1.C, all street frontages must have curbs and sidewalks. The Land Survey Exception has no provision for assurances for these required elements. The land survey can be approved after the sidewalks and curbs have been constructed. A right-of-way permit will be required. 2. Provide a clear tie including distance and bearing from the basis of bearing to a corner of the proposed project. If you have any questions, please feel free to contact me at 791-5550 x 1161 or at loren.makus@tucsonaz.gov Loren Makus Senior Engineering Associate Engineering Division Development Services Dept. |
| 12/29/2005 | DALE KELCH | COT NON-DSD | TRAFFIC | Approved | >>> Dale Kelch 12/28/2005 3:00:01 PM >>> Traffic Engineering recommends APPROVAL of this ROS. D. Dale Kelch, PE Senior Engineering Associate Traffic Engineering Division (520)791-4259x305 (520)791-5526 (fax) dale.kelch@tucsonaz.gov |