Plan Review Detail
Review Status: Completed
Review Details: RECORD OF SURVEY REVIEW
Plan Number - S05-196
Review Name: RECORD OF SURVEY REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/04/2006 | FRODRIG2 | COT NON-DSD | REAL ESTATE | Denied | There are no real estate action items here unless the developer decides to purchase the undeveloped right of way abutting its project as suggested months ago. If, however, the undeveloped right of way is not sold to the abutting owners, the developer should be required to improve the right of way to TDOT's satisfaction. One option or mechanism to accomplish the improvements, with TDOT's approval, may be through an improvement district with the other abutting property owner participating in the improvement. Otherwise, a bond and assurances should be issued. It should also be noted that the other abutting property owner has and is constructing units along the east side of Mountain (1320 E 16th and 610 S. Highland). Since these are likely site plans that Real Estate will not see, please apply the same conditions to these properties as stated above for S05-196. |
| 01/04/2006 | PATRICIA GEHLEN | ZONING-RECORDATION | REVIEW | Needs Review | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES January 4, 2006 Liz Farkas Rob Paulus Architect, LTD. 116 East Congress Street Tucson, AZ 85701 Subject: S05-196 16th and Mountain Record of Survey Dear Liz: Your submittal of October 26, 2005, for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLUELINES MUST BE FOLDED 6 Copies Revised Record of Survey (wastewater, real estate, engineering, zoning, addressing, DSD) Should you have any questions, please call me at 791-5608, ext 1179. Sincerely, Patricia Y. Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 622-8334 |
| 01/06/2006 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | see comments under recordation |
| 10/26/2005 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 10/28/2005 | JOE LINVILLE | LANDSCAPE | REVIEW | Approved | |
| 10/28/2005 | JIM EGAN | COT NON-DSD | FIRE | Approved | The plan is approved October 28, 2005. |
| 11/01/2005 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Approved | SUBJECT: 16th & Mountain S05-196 Tucson Electric Power Company has reviewed and approved the plans submitted October 26, 2005. In order to apply for electric service, call the New Construction Department at (520) 770-2062. Submit a final set of plans including approved site, offsite and electrical load plans. Include a CD with the AutoCAD version of the plans. If easements are required, they will be secured by separate instrument. Your final plans should be sent to: Mike Kaiser Design/Build - DB 102 Tucson Electric Power Company P. O. Box 711 Tucson, AZ 85702 Please call me at (520) 917-8745, should you have any questions. Liza Castillo Right of Way Agent Land Management Tucson Electric Power Co. (520) 917-8745 lcastillo@tep.com |
| 11/07/2005 | TOM MARTINEZ | OTHER AGENCIES | AZ DEPT TRANSPORTATION | Approved | NO COMMENT S05-196 ROB PAULUS ARCHITECT, LT 16TH & MOUNTAIN ********************************************************************* Confidentiality and Nondisclosure Notice: This email transmission and any attachments are intended for use by the person(s)/entity(ies) named above and may contain confidential/privileged information. Any unauthorized use, disclosure or distribution is strictly prohibited. If you are not the intended recipient, please contact the sender by e-mail, and delete or destroy all copies plus attachments. Neither the State nor the Arizona Department of Transportation and/or its employees shall be liable for violations of law, or damages resulting from your dissemination or use of this email transmission if you are not the intended recipient. ********************************************************************* |
| 11/08/2005 | JCLARK3 | ENV SVCS | REVIEW | Approved | * No known landfill with in 1000 feet of this development. * Residential lot split. Refuse service to be Automated Plastic Containers (APC) which will be picked up off 16th Street. Residents to place and remove the APC's from the collection area on the day of service. Screen storage area should be provided on the individual lot. |
| 11/09/2005 | ROGER HOWLETT | COT NON-DSD | COMMUNITY PLANNING | Approved | DEPARTMENT OF URBAN PLANNING & DESIGN Regarding SUBJECT: Community Design Review Committee Application CASE NUMBER: CASE NAME: DATE SENT S05-196 16th & Mountain 11/07/05 () Tentative Plat () Development Plan () Landscape Plan () Revised Plan/Plat () Board of Adjustment (xxxxx) Other – Record of Survey CROSS REFERENCE: NEIGHBORHOOD PLAN: Arroyo Chico GATEWAY/SCENIC ROUTE: COMMENTS DUE BY: SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: (XXXX) No Annexation or Rezoning Conditions, Not an RCP - No Comment () Proposal Complies with Annexation or Rezoning Conditions () RCP Proposal Complies With Plan Policies () See Additional Comments Attached () No Additional Comments - Complies With Planning Comments Submitted on: () Resubmittal Required: () Tentative Plat () Development Plan () Landscape Plan () Other REVIEWER: D. Estolano 791-4505 DATE: 11/07/05 |
| 11/10/2005 | KAY MARKS | PIMA COUNTY | ADDRESSING | Denied | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 KAY MARKS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: KAY MARKS, ADDRESSING OFFICIAL SUBJECT: S05-196 16TH & MOUNTAIN RECORD OF SURVEY REVIEW DATE: 11/09/05 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval: Delete all street directions. Add street name to Manlove and Avenue to Santa Rita on Location Map. Correct Location Map scale. Delete 1246 E. 16th St. Spell out Avenue of Santa Rita Ave. Recorded deeds with legal descriptions will need to be provided in order to issue addresses. |
| 11/14/2005 | MARILYN KALTHOFF | PIMA COUNTY | WASTEWATER | Denied | November 10, 2005 To: Liz Farkas, Rob Paulus Arch. Thru: Patricia Gehlen, CDRC Project Manager City of Tucson Development Services Department ____________________________________ From: Tim Rowe, P.E. (520-740-6563), representing the Pima County Departments of Wastewater Management and Environmental Quality Subject: 16th and Mountain - Record of Survey Record of Survey - 1st Submittal S05-196 The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. 1. This project will be tributary to the Roger Road Wastewater Treatment Facility via the Aviation Corridor to Santa Cruz Interceptor Sewer. Treatment and conveyance capacity within the downstream public sewer system exists for this very small project. 1. The applicable sewer connection fee rate cannot be determined at this time. The determination of applicable rate will need to be done at the time of issuance of building permits. 1. All Sheets: Add the subdivision exception case number, S05-196, to the title block of each sheet. This number should be shown larger or bolder than any cross reference numbers. No wastewater review fees will be charged for sheets where this is the only required revision. 1. My examination of the amended plat for the Manlove Addition, recorded at Book 3, Page 12, M&P does not confirm that the any of the easements shown on the Record of Survey and identified in Exhibits A-E were granted by that document. Advise / revise as necessary. If these easement are proposed easements, the COT CDRC will require that they be granted by separate instrument, and the phrase PER DOCKET _______, PAGE _______ will need to be added to the labels for each of the easements. The blanks in these labels will need be filled in with the appropriate recording information before the Record of Survey can be recorded. 1. If Parcels B and C will share a private sewer line that connects to the public sewer system, a Joint Use and Maintenance Agreement must be prepared, reviewed and approved by PCWMD Development Services Section staff, and recorded, prior to the issuance of building permits for those parcels. Add a General Note that states: PRIOR TO THE ISSUANCE OF BUILDING PERMITS FOR PARCELS B AND C, A JOINT USE AND MAINTENANCE AGREEMENT SHALL BE RECORDED FOR ANY SHARED PRIVATE SEWER LINE(S). PRIOR TO RECORDATION, THE REQUIRED AGREEMENT SHALL BE REVIEWED AND APPROVED BY THE PIMA COUNTY WASTEWATER MANAGEMENT DEPARTMENT. 1. We will require a revised set of bluelines, and a response letter, addressing these comments. Additional comments may be made during the review of these documents. County Ordinance 2003-29 went into effect on April 11, 2003. This ordinance requires that a wastewater review fee be paid for each submittal of the Record of Survey. The fee for the first submittal is $166 plus $50 per sheet. For the second submittal, the review fee is $50 per sheet. For all subsequent submittals, the review fee is $39 per sheet. The next submittal of this project will be the second (2nd) submittal. A check for the review fee of this submittal in the amount of $50.00 (made out to PIMA COUNTY TREASURER ) must accompany the revised set of bluelines and response letter. If the number of sheets changes, please adjust the review fee accordingly. If you have any questions regarding the above mentioned comments, please contact me at the telephone number shown under my signature on the first page of this letter CC: Project File |
| 11/15/2005 | GLENN HICKS | COT NON-DSD | PARKS & RECREATION | Approved | DATE: November 15, 2005 TO: Ferne Rodriguez, Development Services FROM: Glenn Hicks Parks and Recreation 791-4873 ext. 215 Glenn.Hicks@tucsonaz.gov SUBJECT: S05-196 16th & Mountain: Record of Survey Review Staff has no comments. |
| 11/15/2005 | FRODRIG2 | OTHER AGENCIES | PIMA ASSN OF GOVTS | Approved | 29 estimated trips in a 24 hr period. |
| 11/22/2005 | DALE KELCH | COT NON-DSD | TRAFFIC | Approved | Traffic Engineering recommends APPROVAL of this ROS. D. Dale Kelch, PE Senior Engineering Associate Traffic Engineering Division (520)791-4259x305 (520)791-5526 (fax) dale.kelch@tucsonaz.gov |
| 11/28/2005 | MICHAEL ST. PAUL | ZONING | REVIEW | Denied | CDRC TRANSMITTAL FROM: Michael St.Paul Planner Technician PROJECT: S05-196 1246 East 16th Street Record of Survey TRANSMITTAL: November 25, 2005 COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. This review is for a Record of Survey, which is a subdivision exception, in the C-3 Zone (DS 2-03.11 and LUC Sec 2.5.5.2.F.1). The proposed use is a single family residence (SFR) on each lot. The Development Designator is "S" and the Perimeter Yard Indicator is CC (LUC Sec 3.2.3.1.D and 3.2.6.4). 2. There is limited access to proposed lots B and C. Therefore please provide a note, under "General Notes," that says: "Parcels B and C shall be limited to one single family residence (SFR) on each parcel." You may also include parcel A to insure consistency of your development, if you like. 3. The Record of Survey number is S05-196. Please place this information in the space you have provided above the title block. 4. Please provide the number of proposed lots (3) in the title block (DS 2-03.11.7F.3). 5. Please provide the phrase "a resubdivision of" before "Manlove Amended Lots 10 & 11 Blk 15…" (DS 2-03.11.F.4). 6. This Record of Survey was approved for submittal with the stipulation of being submitted with a Development Standards Modification Request (DSMR), but there is no DSMR provided; nor is there any apparent reason for a DSMR. Please tell us about this mysterious DSMR? |
| 12/19/2005 | LOREN MAKUS | ENGINEERING | REVIEW | Denied | DATE: December 19, 2005 To: Patricia Gehlen CDRC/Zoning Manager FROM: Loren Makus, EIT Engineering Division SUBJECT: 16th and Mountain Record of Survey S04-196 (First Review) T14S, R14E, Section 18 RESUBMITTAL REQUIRED: Record of Survey The Record of Survery has been reviewed by the Engineering Division and we do not recommend approval at this time. The following review comment must be addressed. 1. In accordance with the draft development standard for Records of Survey, a five foot sidewalk must be provided along the 16th Street frontage before the record of survey can be approved. If you have any questions, I can be reached at 791-5550 x1161 or loren.makus@tucsonaz.gov. Loren Makus, EIT Senior Engineering Associate |