Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Plan Number - S05-193
Review Name: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/25/2006 | MARILYN KALTHOFF | START | PLANS SUBMITTED | Completed | |
| 11/22/2006 | KAY MARKS | PIMA COUNTY | ADDRESSING | Approved | PIMA COUNTY ADDRESSING 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 KAY MARKS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: KAY MARKS, ADDRESSING OFFICIAL SUBJECT: S05-193 SAN SIMEON CONDOMINIUMS/REVISED FINAL PLAT DATE: 11/22/06 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project. ***The Pima County Addressing Section can use digital CAD drawing files when submitted with your final plat Mylar. These CAD files can be submitted through the Pima County Subdivision Coordinator. The digital CAD drawing files expedite the addressing and permitting processes when we are able to insert this digital data into the County's Geographic Information System. Your support is greatly appreciated.*** ES |
| 11/24/2006 | FRODRIG2 | COT NON-DSD | REAL ESTATE | Approved | S05-193 San Simeon Condominiums: Resubmittal - CDRC - Final Plat Review - Right-of-Way w/in the E. 22nd St. corridor is apparently used to accommodate "on-site" parking. Real Estate denies approval until parking is resolved by a temporary revocable easement or reconfiguring parking. |
| 11/24/2006 | FRODRIG2 | COT NON-DSD | REAL ESTATE | Approved | S05-193 San Simeon Condominiums: Resubmittal - CDRC - Final Plat - In reference to previous comments, request reply from Real Estate be changed to "No comment." |
| 12/06/2006 | HEATHER THRALL | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Heather Thrall Senior Planner PROJECT: S05-193 San Simeon Condominiums Final Plat TRANSMITTAL: August 29, 2007 DUE DATE: February 16, 2005 COMMENTS: 1. The last approved site plan for this site, submitted with this project, was approved with erroneous information regarding the right of way on it. It appears in actuality, the parking and the parking maneuvering areas extend into the right of way, which is not permitted per LUC 3.3.4. - parking shall be provided on site. The result of this is an insufficient amount of parking, which requires a Board of Adjustment variance to be granted to maintain the parking as delineated. Any use of the right of way also requires a Temporary Revocable Easement through the City Real Estate division. Note, should the original approved site plan for this development show parking/maneuvering within the right of way, a variance would not be required. Please review the records division at Development Services for further assistance on seeking this document. 2. Should you have any questions on this review, please contact me via email at Heather.Thrall@tucsonaz.gov or at 791-4541x1156. If you have any questions about this transmittal, please call (520) 791-5608. C:\planning\cdrc\finalplat\S05-193.san.simeon.4.fp.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat and additional requested documents. |
| 12/14/2006 | PAUL MACHADO | ENGINEERING | REVIEW | Approved | |
| 12/15/2006 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Approved | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES ***REVISED*** September 14, 2007 Wendell T. Harness Stantec 201 North Bonita Avenue, Suite 101 Tucson, Arizona 85745 Subject: S05-193 San Simeon Condominiums Final Plat Dear Wendell: The above referenced project has been APPROVED by the Community Design Review Committee. Please make any necessary corrections and submit the following documents: (2) Title reports current within the last thirty (30) days. (1) Executed Final Plat Double Matte Océ or Photo Mylar. (1) * Check in the amount of $8.50 per plat page for Mayor & Council distribution made payable to the local print company of your choice or provide an account number to charge. (1) * Check in the amount of $55.00 per plat page for recorded plat distribution made payable to the local print company of your choice or provide an account number to charge. (1) Check made payable to "Pima County Recorder" in the amount of $20.00 per plat page plus a $4.00 handling fee, along with CC&R fees if applicable. CC&R fees are $9.00 for the first 5 pages and $1.00 for each additional page. (1) Executed and notarized CC&R's document (if applicable). *Please do not combine the checks for the printing charges. They are processed at different times and require separate checks. An account number is also acceptable and you can include this information on your transmittal sheet when submitting the above listed items. Assurances (if applicable) must be reviewed by the City Attorney's Office prior to being presented to the Mayor and Council. Plats, CC&R's and assurances must be approved at the same Mayor and Council Meeting. Please expect 5-6 weeks from the date submitted to the date scheduled for Mayor and Council approval. Should you have any questions, please call me at 837-4919. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 750-7470 Fp-approved |