Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: S05-182
Parcel: Unknown

Address:
3630 E 3RD ST

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW

Plan Number - S05-182
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/02/2006 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
03/09/2006 PATRICIA GILBERT ENGINEERING REVIEW Approved TO: Patricia Gehlen; CDRC Coordinator DATE: March 9, 2006

SUBJECT: Engineering review of the Third Street Lofts, Lots 1 through 22, Tentative Plat. The activity number is S05-182.

SUMMARY: TENTATIVE PLAT APPROVED

GENERAL COMMENTS

1. The Drainage Report was reviewed for Tentative Plat purposes only.

2. Please include the Assurance Package with the Final Plat submittal. This package must include the original Third Party Trust, the original Amendment to Trust, a copy of the Trust Agreement, a copy of the Deed, a Title Report and a copy of the location map on an 8" by 11" paper.

3. Include a copy of the CC&Rs with the Final Plat submittal. The specific maintenance notes specified in the Standards Manual for Drainage Design and Floodplain Management, SMDDFM, 14.3.2 must be included on the Final Plat or in the CC&Rs. The term "owner" in the maintenance notes is to be replaced with "Homeowners Association".

4. Please provide a copy of the boundary closure calculations with the Final Plat submittal.

5. A Grading Plan and Permit will be required. Proposed grading in excess of 5,000 yards is designated "engineered grading" and a soils engineering report is required with the Grading Plan submittal. Development Standard 11-01.4.1.C. The Soils Report must also address the requirements detailed in the Standards Manual for Drainage Design and Floodplain Management, SMDDFM, 14.2.6.

7. Proposed developments disturbing areas exceeding 1 acre are subject to AzPDES requirements.

8. All proposed easements must be shown in a surveyable manner on the Final Plat.

9. Flood Use Permit is required prior to grading plan approval.
03/13/2006 JOE LINVILLE LANDSCAPE REVIEW Approved
04/14/2006 TERRY STEVENS ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Terry Stevens
Lead Planner

PROJECT: S05-182 an RCP
Third Street Lofts, Lots 1-22 and Common Areas "A" and "B"
Tentative Plat

TRANSMITTAL: 04/14/06

DUE DATE: 3/16/06

COMMENTS:

1. The Zoning Review Section approves the tentative plat for this subdivision, subject to the following changes on the executed tentative plat. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised tentative plat to verify that those changes do not affect any zoning requirements.

2. Provide the date of the approval (March, 6, 2006) for the DSMR and note that the DSMR was approved without conditions.

3. Provide recordation information (docket and page) for the abandonment of the easement by final plat as noted in note #9 on the tentative plat.

If you have any questions about this transmittal, please call Terry Stevens, (520) 791-5550 @ ext. 2000.

TLS C:\planning\cdrc\tentativeplat\S05-182tp.doc
04/17/2006 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

December 28, 2005

Steven Gregor
Gregor & Grenier Engineering, Inc.
5232 East Pima Street, Suite A
Tucson, AZ 85712

Subject: S05-182 Third Street Lofts Tentative Plat

Dear Steve:

The above referenced plan has been CONDITIONALLY APPROVED by the Community Design Review Committee, subject to the revisions required on the mylars. Please submit the following documents for sign-off.

1 Reproducible Oce or Photo Mylar copy of the Plat, landscape plan and NPPO.

Should you have any questions, please call me at 791-5608, ext 1179.


Sincerely,


Patricia Y. Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 319-1181