Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Plan Number - S05-180
Review Name: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/18/2007 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 10/24/2007 | KAROL ARAGONEZ | ZONING | REVIEW | Approved | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Karol Aragonez Planner PROJECT: S05-180 Tres Pueblos Norte Final Plat Resubmittal TRANSMITTAL DATE: October 24, 2007 DUE DATE: November 16, 2007 COMMENTS: The Zoning Review Section approves the final plat for this subdivision. Should there be any changes requested by other CDRC members, however, the Zoning Review Section approval is void, and we request copies of those changes to insure that those changes do not affect zoning requirements. If you have any questions about this transmittal, please call Karol Aragonez, (520) 837-4960. KAA S:\zoning review\karol\planning\cdrc\finalplat\S05-180fp.doc |
| 11/02/2007 | FRODRIG2 | PIMA COUNTY | WASTEWATER | Approved | November 2, 2007 To: Chuck Martin Rick Engineering Thru: Patricia Gehlen, CDRC Manager City of Tucson Development Services Department From: Chandubhai C. Patel, P.E., Civil Eng. Manager Development Review Division (Wastewater) Pima County Development Services Department Subject: Tres Pueblos Norte, Lots 1 Thru 51 Final Plat – 2nd Submittal S05-180 The drawings for the proposed Final Plat for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. The Pima County Department of Environmental Quality and the Wastewater Management Department hereby approve the above referenced submittal of the Final Plat as received by us on October 16, 2007. Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality. Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution. If you have any questions regarding the above comments, please do not hesitate to contact me. Sincerely, Chandubhai C. Patel, P.E. Phone: 520-740-6563 CC: Project file |
| 11/02/2007 | GLYNDA ROTHWELL | UTILITIES | TUCSON ELECTRIC POWER | Approved | SUBJECT: TRES PUEBLOS NORTE S05-180 The Final Plat for the subject project will meet this TEP's easement requirements. Please forward any resubmittals of the final plat to this office. Electric service will be provided to this subdivision in accordance with the rules and regulations approved by the Arizona Corporation Commission. Please contact me at (520) 917-8745 if you have any questions. Liza Castillo, Right of Way Agent Tucson Electric Power Co. Unisource Energy Services offc-(520) 917-8745 fax-(520) 545-1416 lcastillo@tep.com |
| 11/08/2007 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Approved | Office of the Pima County Assessor 115 N. Church Ave. Tucson, Arizona 85701 BILL STAPLES ASSESSOR TO: CDRC Office Subdivision Review City of Tucson (FAX# 791-5559) FROM: Gary Ault, Mapping Supervisor Pima County Assessor's Office Mapping Department DATE: October 24, 2007 RE: Assessor's Review and Comments Regarding Final Plat S05-180 Tres Pueblos Norte T151408 (140-26) * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * X Plat meets Assessor's Office requirements. _______ Plat does not meet Assessor's Office requirements. COMMENTS: Thank you for your submittal NOTE: THE ASSESSOR'S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED. Susan King |
| 11/09/2007 | KAY MARKS | PIMA COUNTY | ADDRESSING | Approved | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 KAY MARKS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: KAY MARKS, ADDRESSING OFFICIAL SUBJECT: S05-180 TRES PUEBLOS NORTE/REVISED FINAL PLAT DATE: 11/08/07 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project. ***The Pima County Addressing Section can use digital CAD drawing files when submitted with your final plat Mylar. These CAD files can be submitted through Pima County Addressing. The digital CAD drawing files expedite the addressing and permitting processes when we are able to insert this digital data into the County’s Geographic Information System. Your support is greatly appreciated.*** ES |
| 11/15/2007 | ELIZABETH EBERBACH | ENGINEERING | REVIEW | Approv-Cond | DATE: November 15, 2007 TO: Patricia Gehlen; CDRC Coordinator SUBJECT: Tres Pueblos IV Subdivision Final Plat package resubmittal Engineering Review REVIEWER: Elizabeth Eberbach ACTIVITY NUMBER: S05-180 SUMMARY: Development Services Department Engineering Division has completed the review of the revised Final Plat package that included the second supplement to CC&R's, location map, original agreement to construct, original amendment to trust, warranty deed, trust agreement, docket 7098, title report schedule B, and response letter. Engineering recommends conditional approval of the Final Plat. The following conditions associated with the assurances, CC&R's, and minor plat items may be addressed with mylar submittal. FINAL PLAT CONDITIONS OF APPROVAL: 1) City of Tucson Development Standards (DS) Section No. 2-03.7.1.G: The final plat cannot be scheduled for Mayor and Council consideration until the financial assurances are acceptable. Address the following items for the third party trust package: a) Assure that the descriptions of the common areas on the plat and in the descriptions in the Final Plat title block match the descriptions of the subdivision common areas in the assurance paperwork. 'Common Areas "B-1"' is shown on the plat, and 'Common Area "B-1"' is called out on the assurance documents. Either change the plat or the assurances so that descriptions match. Provide revised AMENDMENT TO TRUST / THIRD PARTY TRUST, revised AGREEMENT TO CONSTRUCT and revised CC&R's, or, revise plat's title block. b) Provide a copy of the updated/latest title report. 2) DS Sec.2-03.7.1.E: Provide master CC&R's to show basin/drainage maintenance (including offsite drainage easement), or, assure that the CC&R's are revised to include any maintenance checklist as provided in the Drainage Report for the approved Tentative Plat. Provide signed original of CC&R's. 3) DS Sec.2-03.6.5.B: Assure all existing easements as listed in the Title Report Schedule B are clearly drawn, identified, and labeled on the Final Plat. Specifically, Item 5 slope easement dkt 7494 pg shall be labeled on plat or removed from Title Report if not existent. Revise plat or submit revise title report. Provide status of these easements in response letter. 4) DS Sec.2-03.6.5.C.5: Address the following boundary data and other minor survey items remaining: a) DS Sec.2-03.6.5.B: Provide surveyable distance/bearings for drainage easement along west property boundary. Provide tie for easement to boundary corner or lot / common area corner. b) On mylar, verify crow's feet for distance 74.59' to clarify whether this distance goes to east quarter section line, or to survey monument in Tucson Boulevard. Submit complete assurance package, copy of the updated title report, revised Final Plat (check with CDRC if this is mylar stage), master CC&R's and supplement CC&R's, and response letter. The next submittal should address all the above items. If you have questions or would like to set up a meeting, call me at 837-4934. Elizabeth Eberbach, PE Civil Engineer Engineering Division Development Services |
| 11/16/2007 | FRODRIG2 | COT NON-DSD | REAL ESTATE | Approved | S05-180 Tres Pueblos Norte: Resumittal - CDRC - Final Plat Review -No comment. |
| 11/20/2007 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES November 20, 2007 Chuck Martin Rick Engineering Company 1745 East River Road #101 Tucson, Arizona 85718 Subject: S05-180 Tres Pueblos Norte Final Plat Dear Chuck: The above referenced project has been CONDITIONALLY APPROVED by the Community Design Review Committee. Please make any necessary corrections and submit the following documents: (2) Title reports current within the last thirty (30) days. (1) Executed Final Plat Double Matte Océ or Photo Mylar. (1) * Check in the amount of $8.50 per plat page for Mayor & Council distribution made payable to the local print company of your choice or provide an account number to charge. (1) * Check in the amount of $55.00 per plat page for recorded plat distribution made payable to the local print company of your choice or provide an account number to charge. (1) Check made payable to "Pima County Recorder" in the amount of $20.00 per plat page plus a $4.00 handling fee, along with CC&R fees if applicable. CC&R fees are $9.00 for the first 5 pages and $1.00 for each additional page. (1) Executed and notarized CC&R's document (if applicable). *Please do not combine the checks for the printing charges. They are processed at different times and require separate checks. An account number is also acceptable and you can include this information on your transmittal sheet when submitting the above listed items. Assurances (if applicable) must be reviewed by the City Attorney's Office prior to being presented to the Mayor and Council. Plats, CC&R's and assurances must be approved at the same Mayor and Council Meeting. Please expect 7 - 8 weeks from the date submitted to the date scheduled for Mayor and Council approval. Should you have any questions, please call me at 837-4919. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 322-6956 Fp-approved |