Plan Number: S05-164
Parcel: Unknown

Address: Unknown

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW

Plan Number - S05-164
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/01/2006 MARILYN KALTHOFF START PLANS SUBMITTED Completed
09/21/2006 JOE LINVILLE LANDSCAPE REVIEW Denied 1) Clarify if the portions of the project will be phased and revise the limits of grading if necessary. The grading plan indicates that the entire site will be graded. The grading limits should include only construction indicated and approved on the tentative plat.

2) If the entire site is to be graded as indicated on the landscape plan, then will the entire site receive the dust control treatment indicated on the landscape plan.

3) Revise the plat and landscape plans to include slope ratios and depths for all retention and detention basins. The landscape plan and the tentative plat do not appear to match.
If the depth (the difference between top and bottom elevations) of the basin is three feet or greater the slopes may not be steeper than 4:1. DS 10-01(p. 78).

4) Revise the landscape plan and the tentative plat to match regarding the 20' drainage and landscape easement. The slope treatment proposed on the plat should appear on the landscape plan. Based on the tentative plat, a portion of the
landscape easement will include rock riprap with a filter fabric. Provide details for planting in these conditions if the 2:1 slopes are retained. DS 2-07.2.2.D

5) Provide calculations for the landscape border along I-10.
Fifty (50) percent or more of the area of the 20' street landscape border must be covered with shrubs or vegetative ground cover. LUC 3.7.2.4.A.5, DS 2-06.3.7

6) The 20' drainage/landscape easement along I-10 should be excluded from the note on the landscape regarding individual lot approvals. Based on the plat it appears that the drainage improvements may precede individual lot development.

7) Note 27 on the tentative plat is not applicable.

8) Revise the plans to identify any proposed walls or screening elements. screens along a street frontage must be located on the development side of the street landscape border so that they do not obstruct the view of the street landscape border from the street. LUC 3.7.3.2.B
10/02/2006 TOM MARTINEZ OTHER AGENCIES AZ DEPT TRANSPORTATION Approved NO COMMENT
S05-164
STANLEY ENGINEERING & DRAINAGE, INC.
INTERSTATE BUSINESS PARK

--------------------------------------------------------


Confidentiality and Nondisclosure Notice: This email transmission and any attachments are intended for use by the person(s)/entity(ies) named above and may contain confidential/privileged information. Any unauthorized use, disclosure or distribution is strictly prohibited. If you are not the intended recipient, please contact the sender by e-mail, and delete or destroy all copies plus attachments.
10/23/2006 LOREN MAKUS ENGINEERING REVIEW Approved DATE: October 23, 2006

To: Patricia Gehlen
CDRC/Zoning Manager
FROM: Loren Makus, EIT
Engineering Division

SUBJECT: Interstate Business Park
Tentative Plat S05-164 (Fourth Review)
T14S, R14E, Section 30

RESUBMITTAL REQUIRED: None

The Tentative Plat and Drainage Report have been reviewed by the Engineering Division and we recommend approval at this time.

If you have any questions, I can be reached at 791-5550 x1161 or loren.makus@tucsonaz.gov.

Loren Makus, EIT
Senior Engineering Associate
10/27/2006 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

October 27 2006

Jeff Stanley
P.O. Box 1888
Tucson, AZ 85702

Subject: S05-164 Interstate Business Park Tentative Plat

Dear Jeff:

Your submittal of September 1, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLUELINES MUST BE FOLDED

2 Copies Revised Tentative Plat (Landscape, DSD)

2 Copies Landscape Plan (Landscape, DSD)


PRIOR TO RESUBMITTAL OF THESE PLANS A WRITTEN REQUEST FOR A TENTATIVE PLAT REVIEW EXTENSION MUST BE SUBMITTED TO AND GRANTED BY THE CDRD OFFICE.

Should you have any questions, please call me at 791-5608, ext 1179.

Sincerely,


Patricia Gehlen
CDRC Manager