Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Plan Number - S05-164
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/01/2006 | MARILYN KALTHOFF | START | PLANS SUBMITTED | Completed | |
| 09/21/2006 | JOE LINVILLE | LANDSCAPE | REVIEW | Denied | 1) Clarify if the portions of the project will be phased and revise the limits of grading if necessary. The grading plan indicates that the entire site will be graded. The grading limits should include only construction indicated and approved on the tentative plat. 2) If the entire site is to be graded as indicated on the landscape plan, then will the entire site receive the dust control treatment indicated on the landscape plan. 3) Revise the plat and landscape plans to include slope ratios and depths for all retention and detention basins. The landscape plan and the tentative plat do not appear to match. If the depth (the difference between top and bottom elevations) of the basin is three feet or greater the slopes may not be steeper than 4:1. DS 10-01(p. 78). 4) Revise the landscape plan and the tentative plat to match regarding the 20' drainage and landscape easement. The slope treatment proposed on the plat should appear on the landscape plan. Based on the tentative plat, a portion of the landscape easement will include rock riprap with a filter fabric. Provide details for planting in these conditions if the 2:1 slopes are retained. DS 2-07.2.2.D 5) Provide calculations for the landscape border along I-10. Fifty (50) percent or more of the area of the 20' street landscape border must be covered with shrubs or vegetative ground cover. LUC 3.7.2.4.A.5, DS 2-06.3.7 6) The 20' drainage/landscape easement along I-10 should be excluded from the note on the landscape regarding individual lot approvals. Based on the plat it appears that the drainage improvements may precede individual lot development. 7) Note 27 on the tentative plat is not applicable. 8) Revise the plans to identify any proposed walls or screening elements. screens along a street frontage must be located on the development side of the street landscape border so that they do not obstruct the view of the street landscape border from the street. LUC 3.7.3.2.B |
| 10/02/2006 | TOM MARTINEZ | OTHER AGENCIES | AZ DEPT TRANSPORTATION | Approved | NO COMMENT S05-164 STANLEY ENGINEERING & DRAINAGE, INC. INTERSTATE BUSINESS PARK -------------------------------------------------------- Confidentiality and Nondisclosure Notice: This email transmission and any attachments are intended for use by the person(s)/entity(ies) named above and may contain confidential/privileged information. Any unauthorized use, disclosure or distribution is strictly prohibited. If you are not the intended recipient, please contact the sender by e-mail, and delete or destroy all copies plus attachments. |
| 10/23/2006 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | DATE: October 23, 2006 To: Patricia Gehlen CDRC/Zoning Manager FROM: Loren Makus, EIT Engineering Division SUBJECT: Interstate Business Park Tentative Plat S05-164 (Fourth Review) T14S, R14E, Section 30 RESUBMITTAL REQUIRED: None The Tentative Plat and Drainage Report have been reviewed by the Engineering Division and we recommend approval at this time. If you have any questions, I can be reached at 791-5550 x1161 or loren.makus@tucsonaz.gov. Loren Makus, EIT Senior Engineering Associate |
| 10/27/2006 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES October 27 2006 Jeff Stanley P.O. Box 1888 Tucson, AZ 85702 Subject: S05-164 Interstate Business Park Tentative Plat Dear Jeff: Your submittal of September 1, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLUELINES MUST BE FOLDED 2 Copies Revised Tentative Plat (Landscape, DSD) 2 Copies Landscape Plan (Landscape, DSD) PRIOR TO RESUBMITTAL OF THESE PLANS A WRITTEN REQUEST FOR A TENTATIVE PLAT REVIEW EXTENSION MUST BE SUBMITTED TO AND GRANTED BY THE CDRD OFFICE. Should you have any questions, please call me at 791-5608, ext 1179. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 297-3944 |