Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: S05-164
Parcel: Unknown

Address: Unknown

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW

Plan Number - S05-164
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/09/2006 GLYNDA ROTHWELL UTILITIES TUCSON ELECTRIC POWER Approved SUBJECT: INTERSTATE BUSINESS PARK

S05-164



Tucson Electric Power Company has reviewed and approved the development
plan submitted December 23, 2005.



In order to apply for electric service, call the New Construction
Department at (520) 770-2062. Submit a final set of plans including
approved site, offsite and electrical load plans. Include a CD with the
AutoCAD version of the plans. If easements are required, they will be
secured by separate instrument. Your final plans should be sent to:



Mike Kaiser

Design/Build - DB 102

Tucson Electric Power
Company

P. O. Box 711

Tucson, AZ 85702



Please call me at (520) 917-8745, should you have any questions.




Liza Castillo
Right of Way Agent
Land Management
Tucson Electric Power Co.
(520) 917-8745
lcastillo@tep.com
01/09/2006 LOREN MAKUS ENGINEERING REVIEW Denied DATE: January 9, 2006

To: Patricia Gehlen
CDRC/Zoning Manager
FROM: Loren Makus, EIT
Engineering Division

SUBJECT: Interstate Business Park
Tentative Plat S05-164 (Second Review)
T14S, R14E, Section 30

RESUBMITTAL REQUIRED: Tentative Plat, Drainage Report

The Tentative Plat and Drainage Report have been reviewed by the Engineering Division and we do not recommend approval at this time. The following review comments must be addressed.

Tentative Plat
1. As previously commented, provide documentation that the existing property owners' association will consent to the addition of new street length. Discuss how the streets and drainageways will be maintained.
2. The discharge from this site is expected to be about 138 cfs. Show adjacent drainage facilities to show how the discharge is accommodated off site. (DS 2-03.2.3.G and I)

Drainage Report
3. Provide hydaulic analyses for each drainage structure. Provide calculations of the depth of flow in the 10 foot drainage easements. Provide for adequate freeboard for each open channel. (Standards Manual for Drainageway Design and Floodplain Management in Tucson Arizona Section 8.5.1)
4. Provide hydraulic calculations for the pipe culverts at lot 6. Provide a backwater analysis for the new culverts to demonstrate that there will be sufficient capacity within the existing channel or to determine that channel improvements will be required

Please note that a Stormwater Pollution Prevention Plan and Floodplain Use Permit will be required as part of the grading permit submittal.
Submit a revised Tentative Plat and a revised Drainage Report. Include a detailed response letter, detailing how each comment has been addressed.
If you have any questions, I can be reached at 791-5550 x1161 or loren.makus@tucsonaz.gov.

Loren Makus, EIT
Senior Engineering Associate
01/12/2006 FRODRIG2 COT NON-DSD REAL ESTATE Denied S05-164, Interstate Business Park II, Tentative; Items #8 & 6 of the title report not found on the plat.
01/17/2006 DALE KELCH COT NON-DSD TRAFFIC Approved Traffic Engineering recommends APPROVAL of this TP.

D. Dale Kelch, PE
Senior Engineering Associate
Traffic Engineering Division
(520)791-4259x305
(520)791-5526 (fax)
dale.kelch@tucsonaz.gov
01/20/2006 FRODRIG2 PIMA COUNTY WASTEWATER Approv-Cond January 20, 2006

TO: Jeff Stanley
Stanley Engineering & Drainage

THRU: Patricia Gehlen
City of Tucson, Development Services Department

FROM: R S Engineering (Contract Reviewer)
Subhash Raval, P.E.
Pima County Development Services Department
Development Review Division (Wastewater)

SUBJECT: Interstate Business Park, Lots 1-16
Tentative Plat – 2nd Submittal
S05-164

The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


Provide a letter from PCWWM Planning Services, written within the past 90 days, stating that treatment and conveyance system capacity for this project is available. A capacity request form may be found at http://www.pima.gov/wwm/forms/docs/CapResponseRequest.pdf.
Subject to the above required revisions, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the tentative plat/final plat/development plan.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Department of Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.


If you have any questions regarding the above mentioned comments, please contact me. Sincerely,





Subhash Raval, P.E.
Telephone: (520) 740-6586

Copy: Project
01/21/2006 DAVID RIVERA ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office
FROM: David Rivera
Principal Planner

PROJECT: S05-164
Interstate Business Park, Lots 1-16
Tentative Plat

TRANSMITTAL: January 21, 2006

DUE DATE: January 10, 2006

COMMENTS:

1. Section 4.1.7.1, LUC, permits a maximum of one year from the date of application to obtain approval of a tentative plat. If, at the end of that time, the tentative plat has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this tentative plat is September 9, 2006.

2. I acknowledge your response to the previous comment. Please add the information prior to approval of the tentative plat.

Previous Comment: Draw and label the existing and future curb along the north side of the property. (I acknowledge that this roadway is part of the I-10 freeway system.) DS 2-03.2.3.D

3. It is not clear on the plan if the sidewalks or curbs are existing on the lots 7 through 10. Please draw and label the existing curb and sidewalk.

Previous Comment: Proposed traffic circulation will be designed in accordance with Street Development Standard 3-01.0, to include streets, intersections, street names, right-of-way widths, curve radii of centerlines and curb returns, and proposed improvements, such as pavement, curbs, access points (driveways), handicap ramps, and sidewalks. Street improvements, such as sidewalks, curbs, pavement, and handicap ramps, do not need to be drawn on the plat if such information is provided on typical street cross sections. Indicate if streets are to remain private or are to be dedicated to the public. Indicate the proposed street names, if available. See engineering comments. (DS 2-03.2.4.F)

4. This comment will remain until compliance with the required street cross section or interpretation letter is provided.

Previous Comment: If streets are proposed, indicate if they are designed for on-street parking to accommodate visitor parking or if parking is provided in common parking areas. Visitor parking is to be evenly distributed and usable by all residents of the project. Extra parking on individual lots, such as tandem parking in driveways, does not count toward visitor parking, as it is not available to other property owners within the project. (DS 2-03.2.4.G)


If you have any questions about this transmittal please call David Rivera (520) 791-5608.

DGR C:\planning\cdrc\tentativeplat\S05164tp2.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised, tentative plat, and additional requested documents.
02/09/2006 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

February 9, 2006

Jeff Stanley
P.O. Box 1888
Tucson, AZ 85702

Subject: S05-164 Interstate Business Park Tentative Plat

Dear Jeff:

Your submittal of December 23, 2005 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLUELINES MUST BE FOLDED

7 Copies Revised Tentative Plat (Addressing, Real Estate, Landscape, Zoning, Engineering, ADOT, DSD)

2 Copies NPPO Plan (landscape, DSD)

3 Copies Revised Drainage Report (ADOT, engineering, DSD)


Should you have any questions, please call me at 791-5608, ext 1179.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 297-3944
02/09/2006 TOM MARTINEZ OTHER AGENCIES AZ DEPT TRANSPORTATION Denied ADOT has a couple of comments. First, the access control along I-10 has been called out on the plan but needs to be represented graphically using ADOT drafting standards. Second, we did not receive a copy of the drainage report.
12/23/2005 JOE LINVILLE LANDSCAPE REVIEW Denied 1) A native plant preservation plan or approved application for exception is required for any new road segments proposed and for any required drainage improvements.

2) If the native plant preservation plan results in a requirement for plant mitigation or transplanting, a landscape mitigation plan will be required.

3) Landscape and native plant preservation plans will be required for individual lots, exclusive of infrastructure items when they are developed.
12/23/2005 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
12/30/2005 KAY MARKS PIMA COUNTY ADDRESSING Denied 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S05-164 INTERSTATE BUSINESS PARK / REVISED TENTATIVE PLAT
DATE: DECEMBER 30, 2005



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:


1: Street name "Caprio" is unacceptable. Please choose a new name.