Plan Number: S05-162
Parcel: Unknown

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW

Plan Number - S05-162
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/06/2006 DALE KELCH COT NON-DSD TRAFFIC Denied Traffic Engineering REJECTS this DP:

1. Show and label as to size (ie 20x110) both existing and future SVTs (DS 2-05.2.4.R) If the existing and future SVTs are coincident, label it as both existing and future. There is no near side SVT depicted at either access point.

D. Dale Kelch, PE
Senior Engineering Associate
Traffic Engineering Division
(520)791-4259x305
(520)791-5526 (fax)
dale.kelch@tucsonaz.gov
01/12/2006 TERRY STEVENS ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Terry Stevens
Lead Planner

PROJECT: S05-162 2nd review
Huachuca Condominiums
Tentative/Development Plan

TRANSMITTAL: 01/12/06

DUE DATE: December 30, 2005

COMMENTS:

1. Per DS 2-03.2.2.B.1 This project has been assigned the case number S05-162, list in the lower right corner next to the title block of all pages of the plat including the landscape and NPPO pages

2. Please clarify in the parking calculations that 2 parking spaces are being provided in garages or carports for each lot. Indicate the interior dimensions of the garage or carport (min. size of 17' x 18') in order to comply with the parking space requirements.

3. Per DS 2-05.2.4.K Pedestrian circulation including handicap accessibility must be provided. The handicap ramps at the corners of the front sidewalk will require redesign based on the comments by the traffic reviewer requiring radius curbs at the entrance to the project.

The sidewalk in front of the handicap parking space appears to be flush with the pavement. If this is the case truncated domes will be required for the full width of the access aisle. If the sidewalk is not flush with the pavement a handicap ramp will be required at the access aisle.

4. Per ANSI A-117.1 Sec. 1106.1 A van accessible parking space is required as one of the required visitor parking spaces. Provide a dimensioned detail of the van accessible parking space.

The dimensions provided do not meet ANSI A117.1-2003 Sec. 502.2 requirements for width of a van parking space (min. 11' when used with a 5' access aisle). If an 8' wide access aisle is used then a 8' in width parking spaces is allowed.

5. Per DS 2-05.2.4.R Indicate all sight visibility triangles along Huachuca St. See engineering and traffic comments.

6. Per DS 2-05.2.4.Q Show, on the drawing, the specific type of bicycle rack and the number of bicycles it supports. For specifics, refer to Development Standard 2-09.0.

If you have any questions about this transmittal, please call Terry Stevens, (520) 791-5550 ext. 2000.

TLS C:\planning\cdrc\tentativeplat\S05-162tp.doc
01/20/2006 FRODRIG2 PIMA COUNTY WASTEWATER Denied January 20, 2006

TO: Tony Tsang
A. C. Tsang Engineering Group, Inc.

THRU: Patricia Gehlen
City of Tucson, Development Services Department

FROM: R S Engineering (Contract Reviewer)
Subhash Raval, P.E.
Pima County Development Services Department
Development Review Division (Wastewater)

SUBJECT: Huachuca Condominiums
Tentative Plat – 2nd Submittal
S05-162

The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.



Show the size and Pima County plan number for the existing public sewer. Also show the six digit Pima County manhole number for manhole being tied into.

Show the type of material for all newly proposed sewers.

Show the invert and rim elevations for all manholes.

We will require a revised set of drawings and a response letter addressing each comment. Additional comments may be made during the review of these documents.

The next submittal of this project will be the 3rd submittal. A check for the review fee of this submittal in the amount of $39.00 made out to PIMA COUNTY TREASURER must accompany the revised set of bluelines and response letter.

For any questions regarding the fee schedule, please go to http://www.pimaxpress.com/SubDivision/Documents/Fees.PDF where you may find the appropriate wastewater review fees at the bottom of page 1. If the number of sheets changes, please adjust the review fee accordingly.


If you have any questions regarding the above mentioned comments, please contact me. Sincerely,





Subhash Raval, P.E.
Telephone: (520) 740-6586

Copy: Project
01/25/2006 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

January 25, 2006

Antony C. Tsang
A.C. Tsang Engineering Group, Inc.
4626 East Fort Lowell, Suite S
Tucson, AZ 85712

Subject: S05-162 Huachuca Condominiums Tentative Plat

Dear Tony:

Your submittal of December 15, 2005 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLUELINES MUST BE FOLDED

7 Copies Revised Tentative Plat (Addressing, Wastewater, Landscape, Zoning, Engineering, Traffic, DSD)

4 Copies Revised Landscape Plan (Engineering, Landscape, Zoning, DSD)




Should you have any questions, please call me at 791-5608, ext 1179.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 325-0979
12/15/2005 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
12/21/2005 PAUL MACHADO ENGINEERING REVIEW Denied To: Patricia Gehlen DATE: December 21, 2005
CDRC/Zoning Manager
SUBJECT: Hauchuca Condominiums, 1709 N Huachuca Ave.
Tentative Plat, S05-162 (Second Review)
T14S, R13E, Section 03

RESUBMITTAL REQUIRED: Tentative Plat and Drainage Report.

The Tentative Plat (TP) and Drainage Report (DR) cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Tentative Plat:

1. Please include a response letter to the comments along with the corrected copies of the DP.
2. Label existing and future sight visibility triangles per D.S. 2-02.2.1.10. The near side SVT's shall also be shown on the TP.
3. Please include a detail of the refuse enclosure on the TP. Contact Environmental Services, John Clark for size requirements @ 791-5543 x1136.

Drainage Report:
1. The DR has been accepted for TP purposes only.

If you have any questions, I can be reached at 791-5550 x1193 or Paul.Machado@ci.tucsonaz.govs
Paul P. Machado
Senior Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 791-5550 x1193 office
(520) 879-8010 fax
C:/1709 N Huachuca Ave CDRC2
12/22/2005 GLENN HICKS COT NON-DSD PARKS & RECREATION Approved DATE: December 21, 2005

TO: Ferne Rodriguez, Development Services

FROM: Glenn Hicks
Parks and Recreation
791-4873 ext. 215
Glenn.Hicks@tucsonaz.gov



SUBJECT: S05-162 Huachuca Condominiums: Tentative Plat Review(12-15-05)


Approved
12/22/2005 KAY MARKS PIMA COUNTY ADDRESSING Denied 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S05-162 HUACHUCA CONDOMINIUMS/REVISED TENTATIVE PLAT
DATE: December 20, 2005



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:

Add street to Dragoon and Huachuca on Location Plan per letter dated 09-23-05.

Please refer to the attachment to label the unit numbers for condominiums per letter dated 09-23-05.

















jg
Attachment

ADDRESS STANDARDS 18.83.040

5)Condominiums:
a)Condominium developments shall be assigned a situs address for each building.
b)Individual living facilities in each building shall be assigned occupant identifiers (unit numbers): First floor units shall have 100 series numbers, second floor units shall have 200 series numbers, and additional floors shall be numbered accordingly.
12/23/2005 JOE LINVILLE LANDSCAPE REVIEW Denied 1) Add the CDRC case number to the landscape and native plant preservation plans. DS 2-07.2.1.B

2) If a new development is using a screen on an adjacent property to meet screening requirements, a copy of the recorded covenant locating the existing screen(s) on adjacent property is required. DS 2-03.2.1.A.15

3) Label each common area individually with a separate letter designation. Enclose each with a solid line. DS 2-03.2.4.C

RESUBMITTAL OF ALL PLANS AND THE REQUESTED COVENANT IS REQUIRED.