Plan Review Detail
Review Status: Completed
Review Details: FINAL PLAT REVIEW
Plan Number - S05-152
Review Name: FINAL PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/16/2005 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 09/09/2005 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Approved | SUBJECT: ACADEMY LOFTS S05-152 The Final Plat for the subject project is approved. If easements are required, they will be secured by separate instrument. Please contact me at (520) 917-8745 if you have any questions. Liza Castillo Right of Way Agent Land Management Tucson Electric Power Co. (520) 917-8745 lcastillo@tep.com <mailto:lcastillo@tep.com> |
| 09/09/2005 | KAY MARKS | PIMA COUNTY | ADDRESSING | Denied | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 KAY MARKS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: KAY MARKS, ADDRESSING OFFICIAL SUBJECT: S05-152 ACADEMY LOFTS/FINAL PLAT DATE: September 8, 2005 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval: Delete all street directions on Location Map. Change Sec 15 to 13 and R14E to R13E under Location Map. Delete Bk 1, Pg 12 on Location Map. Change 2/4 to 5/55 on Location Map. Move or arrow Bk 20, Pg 83 to the correct location on Location Map. Add Section, Township and Range to all Title Blocks. Add “A resubdivision of lots 5, 6, 9 and 10...” to all Title Blocks. Spell out all street suffixes except for Location Map. Are unit numbers already in use? If so, these are fine. If not, please refer to the address standards attachment to address condominiums. Also, basement units will have 000 series numbers. jg Attachment: 18.83.040 Addressing Address Standards 5)Condominiums: a)Condominium developments shall be assigned a situs address for each building. b)Individual living facilities in each building shall be assigned occupant identifiers (unit numbers): First floor units shall have 100 series numbers, second floor units shall have 200 series numbers, and additional floors shall be numbered accordingly |
| 09/09/2005 | FRODRIG2 | COT NON-DSD | REAL ESTATE | Approved | No objection. |
| 09/15/2005 | DAN CASTRO | ZONING | REVIEW | Denied | COMMENTS 1. An applicant has one (1) year from the date of approval of tentative plat to obtain approval of a final plat that complies with zoning and other development requirements in effect at the time of application. This final plat must be approved and recorded on or before August 15, 2006. 2. This plat has been assigned subdivision case number S05-152. Note the subdivision case number in the lower right corner of each sheet on all plans. (D.S. 2-03.6.1.K) 3. Revise general note three (3) to the following: "The number of units is 36". (D.S. 2-03.6.2.B) 4. Under general note one (1), delete the sentence "Proposed zoning is HC-2". 5. On sheet 2 of 8, add the building footprint dimensions and bearings. 6. The CC&R's must be revised as follows: On the cover sheet please reference all the subdivision information found in the title block located on each sheet of the final plat (i.e. subdivision name, number of units, and common area). 7. Remove Lot 1 from the title block. There are not lots proposed as it is a condominium project. If you have any questions about this transmittal, please call Dan Castro, (520) 791-5608 ext. 1180. |
| 09/15/2005 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Approved | Office of the Pima County Assessor 115 N. Church Ave. Tucson, Arizona 85701 BILL STAPLES ASSESSOR TO: CDRC Office Subdivision Review City of Tucson (FAX# 791-5559) FROM: Ed Abrigo, Mapping Supervisor Pima County Assessor’s Office Mapping Department DATE: September 14, 2005 RE: Assessor’s Review and Comments Regarding Final Plat S05-152 Academy Lofts T141313 (117-14) * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * X Plat meets Assessor’s Office requirements. ___ ___Plat does not meet Assessor’s Office requirements. COMMENTS: Thank you for your submittal. Please make the following additions/corrections in the final plat. Add the Township, Range and Section in the title block on all sheets. Add common area square footage. If there are any questions, please contact Jessica Shettleroe at 740-4398. NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED. Jessica Shettleroe |
| 09/19/2005 | JOSE ORTIZ | ENGINEERING | REVIEW | Denied | DATE: SEPTEMBER 19, 2005 TO: Patricia Gehlen, CDRC Manager FROM: Jose E. Ortiz Engineering Division SUBJECT: Academy Lofts - Final Condominium Conversion Plat S05-152 (First Review) T14S, R13E, SECTION 13 RESUBMITTAL REQUIRED: Final Plat Engineering has reviewed the received items and does not recommend approval of the Final Plat. 1. Correct the legal description in regards to the Township, Range, and Section 2. If applicable, please identify and callout all locations of various easements onto the final plat. 3. Include all the sheets submitted for review onto the sheet index located on the first sheet. 4. Better define the difference in line types for easements versus bearing/distant call outs for building edges. The two line types are too similar and can be confusing. Add this information to the legend. 5. The basis of bearings should be established from two (2) found, physically monumented points described and shown on the final plat; therefore identify the second found survey point along Sixth Avenue in the vicinity of 14th Street. DS 2-03.6.5.C.1 6. There is a floating Monument symbol at the southeast corner of the property, please tie down or correct location of this monument symbol. 7. Final approval of the Final Plat will not be warranted until all assurances items have been constructed per the approved site plan Activity Number T04CM02683. Please verify that these assurances items have been completed. If you have any questions or need clarification on any of these comments please feel free to contact me at 791-5550 x1191 or Jose.Ortiz@ci.tucsonaz.govs Jose E. Ortiz Civil Engineer City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 791-5550 x1191 office (520) 879-8010 fax |
| 09/30/2005 | FRODRIG2 | PIMA COUNTY | WASTEWATER | Denied | September 30, 2005 TO: Jeff Stanley Jeff Stanley Engineering THRU: Patricia Gehlen City of Tucson, Development Services Department FROM: Dickie Fernández, E.I.T. Pima County Development Services Department Development Review Division (Wastewater) SUBJECT: Academy Lofts, Lot 1, Condominium Units 1-36 and Common Area A Final Plat – 1st Submittal S05-152 The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. This review is being completed without the correct amount of review fees having been submitted. Regardless of the sheets that involve sewer information, all applicants shall pay the fees as shown on the fee schedule. Following the fee schedule, this project requires an additional $300.00 in review fees. Please refer to the last item of this review letter to know what the total fees will be for the second submittal of this project. Based on the evaluation of historical sewer improvement district maps, this project would qualify for Participating sewer connection fee rates. SHEET 1. Show the trust number in the Dedication. Once this trust number is shown, a sewer service agreement will be prepared for this project. No new drawings are required, however this plan project will not be approved until the remaining $300.00 is paid and the requested information on item three is provided so that a sewer service agreement may be prepared. After the sewer service agreement has been completely processed, the project will be eligible for approval. If you have any questions regarding the above mentioned comments, please contact me. Sincerely, Dickie Fernández, E.I.T. Telephone: (520) 740-6947 Copy: Project |
| 09/30/2005 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES September 30, 2005 Jeffrey A. Stanley Stanley Engineering & Drainage PO Box 1888 Tucson, AZ 85702 Subject: S05-152 Academy Lofts Final Plat Dear Jeff: Your submittal of August 16, 2005 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLUELINES MUST BE FOLDED 5 Copies Revised Final Plat (Addressing. Wastewater, Zoning, Engineering, DSD) 2 Copies Revised CC&R's (Zoning, DSD) Should you have any questions, please call me at 791-5608 ext. 1179. Sincerely, Patricia Y. Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 299-8777 |