Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL- RECORD OF SURVEY
Plan Number - S05-146
Review Name: RESUBMITTAL- RECORD OF SURVEY
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/02/2006 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 03/10/2006 | FRODRIG2 | PIMA COUNTY | WASTEWATER | Denied | March 8, 2006 TO: Gene Johnson Benjamin Design and Drafting THRU: Patricia Gehlen City of Tucson, Development Services Department FROM: Dickie Fernández, E.I.T. Pima County Development Services Department Development Review Division (Wastewater) SUBJECT: 313 E Mohave Road, Lots A, B & C Record of Survey – 2nd Submittal S05-146 The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. Please be aware that the format of the drawings submitted shall be 24” x 36”. The next submittal shall include the two sheets in this required format. Both sheets need to be stamped by a professional engineer or a registered land surveyor. Please seal both sheets with a date and signature for your next submittal. Please be aware that the project name shall be included in both sheets. Revise as necessary. As previously requested on September 21, 2005, please show the recording information for the sewer easement. The proposed private sewer shall be shown all the way to its point of connection with the existing public sewer. Please revise accordingly. Show the length, size and slope of the proposed private sewer. Show the rim and invert elevations for any cleanouts/manholes that may be proposed for this private sewer project. Show the size and Pima County plan number for the existing public sewer. If there are any existing public manholes shown on the record of survey, show their respective six-digit Pima County manhole number. SHEET 1. Add the following General Note ON-SITE SANITARY SEWERS WILL BE PRIVATE AND WILL BE CONSTRUCTED, OPERATED AND MAINTAINED ON A PRIVATE BASIS. THE LOCATION AND METHOD OF CONNECTION TO AN EXISTING PUBLIC SANITARY SEWER IS SUBJECT TO REVIEW AND APPROVAL BY THE PIMA COUNTY WASTEWATER MANAGEMENT DEPARTMENT AT THE TIME OF SUBMITTAL OF PLUMBING OR BUILDING PLANS. SHEET 1. Add the following General Note A PROJECT CONSTRUCTION PERMIT MUST BE SECURED FROM PIMA COUNTY WASTEWATER MANAGEMENT DEPARTMENT BEFORE BEGINNING ANY WORK ON THIS PROJECT. We will require a revised set of drawings and a response letter addressing each comment. Additional comments may be made during the review of these documents. The next submittal of this project will be the 3rd submittal. A check for the review fee of this submittal in the amount of $78.00 made out to PIMA COUNTY TREASURER must accompany the revised set of bluelines and response letter. For any questions regarding the fee schedule, please go to http://www.pimaxpress.com/SubDivision/Documents/Fees.PDF where you may find the appropriate wastewater review fees at the bottom of page 1. If the number of sheets changes, please adjust the review fee accordingly. If you have any questions regarding the above mentioned comments, please contact me. Sincerely, Dickie Fernández, E.I.T. Telephone: (520) 740-6947 Copy: Project |
| 03/14/2006 | KAY MARKS | PIMA COUNTY | ADDRESSING | Approv-Cond | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 KAY MARKS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: KAY MARKS, ADDRESSING OFFICIAL SUBJECT: S05-146 MOHAVE RD. 315 & 317/RECORD OF SURVEY DATE: 3/14/06 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project. Approved with the following condition: Spell out all suffixes for street names on recorded Record of Survey. Note: Provide blackline copy of Recorded Record of Survey and recorded deeds prior to assignment of addresses. es |
| 04/25/2006 | JOSE ORTIZ | ENGINEERING | REVIEW | Denied | DATE: APRIL 27, 2006 TO: Patricia Gehlen, CDRC Manager FROM: Jose E. Ortiz Engineering Division SUBJECT: 315&317 Mohave Road Lot Split Record of Survey S05-146(Second Review) T13S, R13E, SECTION 25 RESUBMITTAL REQUIRED: Record of Survey Engineering has reviewed the received items and does not recommend approval of the Record of Survey. The following items must be revised or added to the plan. Include a response letter with the next submittal that states how all comments have been addressed. 1. Following comments were not fully addressed during the previous submittal. Comment # 13: All plans are to include the following note: "Any relocation or modification of existing utilities and/or public improvements necessitated by the proposed development will be at no expense to the public." Comment # 14: Review the following information and place the portion that applies to this project Record of Survey Standard Paragraphs A. Certificate of Survey. Include the following paragraph signed and sealed by a Registered Professional Land Surveyor: CERTIFICATE OF SURVEY "I hereby certify that the boundary survey as shown on this Record of Survey was performed under my direction and that all existing or proposed survey monuments and markers shown are correctly described. I further certify that this Record of Survey was prepared under my direction." Comment # 19: The following information regarding the existing public right-of-way will be provided: the name, right-of-way width, recordation data, type and dimensioned width of paving, curbs, curb cuts, and sidewalks. 2. Your comment response to number 20 indicates that there is a 6" CV line 22' from centerline in the center of the street, and an 8" line per PCWMD. Please show this information on the record of survey and ensure that the proposed lot configuration has no adverse effects to the existing/proposed utilities. 3. For clarity please add BOB to the legend it's assumed that BOB stands for Basis of Bearing. If you have any questions or need clarification on any of these comments please feel free to contact me at 791-5550 x1191 or Jose.Ortiz@ci.tucsonaz.govs Jose E. Ortiz Civil Engineer City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 791-5550 x1191 office (520) 879-8010 fax |
| 04/27/2006 | MICHAEL ST. PAUL | ZONING | REVIEW | Denied | CDRC TRANSMITTAL FROM: Michael St.Paul, Planning Technician PROJECT: S05-146 313, 315 & 317 East Mohave Road Record of Survey for lot split 2nd review TRANSMITTAL: April 27, 2006 COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1) This review is for a record of survey for splitting an existing lot, with one single-family residence (SFR), into three lots. Please refer to the draft for Land Survey Exception for the requirements for the plans (DS 2-03.11.0). 2) Please provide a plot plan for Parcel A with dimensioned setback and lot coverage calculations. Also provide dimensioned elevation drawings. Refer to the plot plan instruction from the Zoning Review Section (2003 IRC: R106.2). 3) The plot plans for the Parcels B and C must be reviewed separately after the record of survey has had final approval. Place a note on the record of survey stating that the individual plot plans require separate review. 4) Each sheet for the Record of Survey must be twenty-four inches by thirty-six inches (24" X 36") with a two inch (2") margin on thew left side and one-half inch (½") margins of the remaining sides (DS 2-03.11.7.B). 5) All lettering and dimensions must be twelve (0.12) point or larger on the record of survey (DS 2-03.11.7.C). 6) Identify all the subdivisions and any survey plats, along with the map and page recording data, that are located within the area of the projection map on the record of survey (DS 2-03.11.7.D.2). 7) Label the section corners on the projection map (DS 2-03.11.7.D.3). 8) In the title block under "Record of Survey" add as "resubdivision of…" followed by the legal description. Also provide the proposed name for this Record of Survey (DS 2-03.11.7.F.2). 9) List as a general note: "Existing zoning is ____." (DS 2-03.11.8.B.2). 10) Add the following note: "The number of lots is ____." (DS 2-03.11.8.B.3). 11) In the general notes state the gross area of the existing parcel (DS 2-03.11.8.B.4). 12) Add the following note: "There will be no further division lo lots without the expressed approval of the City of Tucson." (DS 2-03.11.8.B.5). 13) Also provide this note: "Any relocation or modification of existing utilities and/or public improvements necessitated by the proposed development will be at no expense to the public." (DS 2-03.11.8.C.1). 14) Please add the following Certificate of Survey: "I hereby certify that the boundary survey as shown on this Record of Survey was performed under my direction and that all existing or proposed survey monuments and markers shown are correctly described. I further certify that this Record of Survey was prepared under my direction." (DS 2-03.11.9.A). 15) All easements of record must be delineated with dimensions on the Record of Survey. The use and the docket and page must be provided for each easement (DS 2-03-11.11.A). Please remove Note # 1 from this Record of Survey. 16) Please provide the right-of-way (ROW) width, recordation data, type and dimensioned width of paving, curbs, curb cuts and sidewalks on the Record of Survey (DS 2-03.11.11.B). 17) The proposed easement and driveway appears to be adjacent to the driveway for the adjacent property to the west. The minimum distance between driveways is twelve feet (12'-0") (Ord. No. 25-38). 18) Identify each proposed lot by number (DS2-03.11.12.D). 19) Please be aware that there may be additional comments relative to any changes made to the Record of Survey and additional information provided with subsequent submittals. |
| 05/04/2006 | PATRICIA GEHLEN | ZONING-RECORDATION | REVIEW | Needs Review | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES May 4, 2006 Claudio Hahn 3212 North Gerinimo Tucson, AZ 85705 Subject: S05-146 Mohave Road 315 & 317 Record of Survey Dear Claudio: Your submittal of March 2, 2006, for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLUELINES MUST BE FOLDED 4 Copies Revised Record of Survey (Engineering, Zoning, Wastewater, DSD), Should you have any questions, please call me at 791-5608, ext 1179. Sincerely, Patricia Y. Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 887-2078 |
| 05/04/2006 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES May 4, 2006 Claudio Hahn 3212 North Gerinimo Tucson, AZ 85705 Subject: S05-146 Mohave Road 315 & 317 Record of Survey Dear Claudio: Your submittal of March 2, 2006, for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLUELINES MUST BE FOLDED 4 Copies Revised Record of Survey (Engineering, Zoning, Wastewater, DSD), Should you have any questions, please call me at 791-5608, ext 1179. Sincerely, Patricia Y. Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 887-2078 |