Plan Review Detail
Review Status: Completed
Review Details: OTHER SUBDIVISION REVIEW
Plan Number - S05-125
Review Name: OTHER SUBDIVISION REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/21/2005 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 07/26/2005 | JIM EGAN | COT NON-DSD | FIRE | Approved | The plan is approved July 26, 2005. |
| 07/26/2005 | FRODRIG2 | COT NON-DSD | REAL ESTATE | Approved | No objection |
| 07/29/2005 | TOM MARTINEZ | OTHER AGENCIES | AZ DEPT TRANSPORTATION | Approved | NO COMMENT S05-125 PHYSICAL RESOURCE ENGINEERING, INC 24th & PARK HABITAT FOR HUMANITY |
| 08/03/2005 | JCLARK3 | ENV SVCS | REVIEW | Approved | * No known landfill with in 1000 feet of this development. * Approved for APC curbside service. * APC's are to be placed and removed from the collection area on the day of service. |
| 08/04/2005 | GLENN HICKS | COT NON-DSD | PARKS & RECREATION | Approved | DATE: August 1, 2005 TO: Ferne Rodriguez, Development Services FROM: Glenn Hicks, Parks and Recreation SUBJECT: S05-125 24th St & Park Habitat for Humanity: Other Subdivision Review(7-21-05) CC: Craig Gross Patricia Gehlen Staff has no comments. Glenn Hicks Parks and Recreation 791-4873 ext. 215 Glenn.Hicks@tucsonaz.gov |
| 08/04/2005 | ROGER HOWLETT | COT NON-DSD | COMMUNITY PLANNING | Approved | DEPARTMENT OF URBAN PLANNING & DESIGN Regarding SUBJECT: Community Design Review Committee Application CASE NUMBER: CASE NAME: DATE SENT S05-125 24th & Park Habitat for Humanity 08/04/05 () Tentative Plat () Development Plan () Landscape Plan () Revised Plan/Plat () Board of Adjustment () Other – Land Survey Exception CROSS REFERENCE: n/a NEIGHBORHOOD PLAN: Greater South Park GATEWAY ROUTE: n/a COMMENTS DUE BY: August 18, 2005 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: () No Annexation or Rezoning Conditions, Not an RCP - No Comment () Proposal Complies with Annexation or Rezoning Conditions () RCP Proposal Complies With Plan Policies () See Additional Comments Attached () No Additional Comments - Complies With Planning Comments Submitted on: () Resubmittal Required: () Tentative Plat () Development Plan () Landscape Plan () Other – REVIEWER: vf 791-4505 DATE: August 4, 2005 |
| 08/08/2005 | MARILYN KALTHOFF | PIMA COUNTY | WASTEWATER | Denied | August 8, 2005 TO: Dan White Physical Resource Engineering, Inc. THRU: Patricia Gehlen City of Tucson, Development Services Department FROM: Dickie Fernández, E.I.T. Pima County Development Services Department Development Review Division (Wastewater) SUBJECT: 24th & Park Habitat for Humanity Record of Survey - 1st Submittal S05-125 The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. 1. This project will be tributary to the Roger Road Wastewater Treatment Facility via the Southeast Interceptor. Provide a letter from PCWWM Planning Services, written within the past 90 days, stating that treatment and conveyance system capacity for this project is available. A capacity request form may be found at http://www.pima.gov/wwm/forms/docs/CapResponseRequest.pdf. 2. Based on the evaluation of historical sewer improvement district maps, this project would qualify for Participating sewer connection fee rates. 3. Add the project number, S05-125, to the title block of each sheet. This number should be shown larger or bolder than any cross-reference numbers. 4. Add the following General Notes ON-SITE SANITARY SEWERS WILL BE PRIVATE AND WILL BE CONSTRUCTED, OPERATED AND MAINTAINED ON A PRIVATE BASIS. THE LOCATION AND METHOD OF CONNECTION TO AN EXISTING PUBLIC SANITARY SEWER IS SUBJECT TO REVIEW AND APPROVAL BY THE PIMA COUNTY WASTEWATER MANAGEMENT DEPARTMENT AT THE TIME OF SUBMITTAL OF PLUMBING OR BUILDING PLANS. ANY WASTEWATER DISCHARGED INTO THE PUBLIC SANITARY SEWERAGE SYSTEM SHALL MEET THE REQUIREMENTS OF THE INDUSTRIAL WASTE ORDINANCE (PIMA COUNTY ORDINANCE NO. 1991-140, AS AMENDED). A PROJECT CONSTRUCTION PERMIT MUST BE SECURED FROM PIMA COUNTY WASTEWATER MANAGEMENT DEPARTMENT BEFORE BEGINNING ANY WORK ON THIS PROJECT. 5. The project requires a Joint Use & Maintenance Agreement. Please contact Pima County Wastewater Management Department's Ilene Deckard at (520) 740-6544 to process this requirement. 6. We will require a revised set of drawings and a response letter addressing each comment. Additional comments may be made during the review of these documents. The next submittal of this project will be the 2nd submittal. A check for the review fee of this submittal in the amount of $100.00 made out to PIMA COUNTY TREASURER must accompany the revised set of bluelines and response letter. For any questions regarding the fee schedule, please go to http://www.pimaxpress.com/SubDivision/Documents/Fees.PDF where you may find the appropriate wastewater review fees at the bottom of page 1. If the number of sheets changes, please adjust the review fee accordingly. If you have any questions regarding the above mentioned comments, please contact me. Sincerely, Dickie Fernández, E.I.T. Telephone: (520) 740-6947 Copy: Project |
| 08/09/2005 | JOE LINVILLE | LANDSCAPE | REVIEW | Approved | |
| 08/09/2005 | KAY MARKS | PIMA COUNTY | ADDRESSING | Denied | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 KAY MARKS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: KAY MARKS, ADDRESSING OFFICIAL SUBJECT: S05-125 24TH & PARK HABITAT FOR HUMANITY/OTHER SUBDIVISION REVIEW DATE: 8/05/05 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval: Delete H. Bruckners 7/60 from Location Map. Correct Bruckners 4/81 to 4/81-C on Location Map. Correct Section 36, T13S, R13E to Section 19, T14S, R14E on Location Map. Add recording Book and Page to McInnes Addition in Title Block. You will need to provide copies of recorded deeds for each lot prior to addressing. |
| 08/18/2005 | DALE KELCH | COT NON-DSD | TRAFFIC | Approved | Traffic Engineering recommends APPROVAL of this Record of Survey. D. Dale Kelch, PE Senior Engineering Associate Traffic Engineering Division (520)791-4259x305 (520)791-5526 (fax) dale.kelch@tucsonaz.gov |
| 08/22/2005 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Approved | SUBJECT: 24TH & PARK HABITAT FOR HUMANITY S05-125 Tucson Electric Power Company has reviewed and approved the plan submitted for review July 21, 2005. Enclosed is a copy of a TEP facilities map showing the approximate location of the existing facilities. There is an existing pole (#58) that appears to be in conflict with the driveway, all costs associated with the relocation of existing facilities will be billable to the developer. In order to apply for electric service, call the New Construction Department at (520) 770-2062. Submit a final set of plans including approved site, offsite and electrical load plans. Include a CD with the AutoCAD version of the plans. If easements are required, they will be secured by separate instrument. Liza Castillo Right of Way Agent Land Management Tucson Electric Power Co. (520) 917-8745 lcastillo@tep.com <mailto:lcastillo@tep.com> |
| 08/29/2005 | ELIZABETH EBERBACH | ENGINEERING | REVIEW | Denied | Comments will be posted on 08-18-05. PM. |
| 08/29/2005 | ELIZABETH EBERBACH | ENGINEERING | REVIEW | Denied | TO: Physical Resource Engineering SUBJECT: Record of Survey, Lot 13, 24th Street & Park Avenue Final Plat S05-125 (First Review) LOCATION: T14S, R14E, Section 19 REVIEWER: Elizabeth Eberbach ACTIVITY: S05-125 SUMMARY: The Record of Survey cannot be approved as submitted. Please address the following review comments prior to the next submittal. RECORD OF SURVEY COMMENTS: 1) DS Sec.2-03.1110.C.1: Label and show the Basis of Bearing. 2) DS Sec.2-03.11.8.6: Show a 1' no vehicle access easement along the West boundary line. 3) DS Sec.2-03.1110.A: At least one corner of the subdivision will be tied to by course and distance to a section corner, quarter section corner; show on planview. 4) DS Sec.2-03.1110.C.4: Indicate whether distances between monuments are measured, recorded, or calculated. 5) DS Sec.2-03.11.7.I: Include all symbols used on the survey in a legend. 6) DS Sec.2-03.6.1.D.3: Correct Township/range and section on location map. 7) DS Sec.2-03.6.5.B: Per discussions at the counter with the customer, show revised locations of the 15' ingress/egress easement on the Record of Survey. 8) DS Sec.2-03.6.5.B: Per discussions at the counter with the customer, show revised location of driveway apron for Lot 1. 9) DS Sec. 6-01.2.2.A: Provide confirmation that Environmental Services Solid Waste Department has approved the proposed curbside pick-up. State in the response letter how Solid Waste will be picked-up and provide correspondence regarding the proposed Solid Waste pick-up for Environmental Services; John Clark: contact. 10) DS Sec.2-03.6.1.K: Label the Subdivision number (S05-125). 11) DS Sec.2-03.6.5.C.3: Please submit a copy of the subdivision boundary closure calculations. 12) DS Sec.11-01.2.1.A: Due to the existing topography at the site and the floodplain elevations within the south right-of-way, a grading plan will be required at construction development stage to assure fill condition for the parcel. The grading plan will need to show fill for Lots 1, 2 and 3, with a minimum fill for Lot 3 at one foot above curb. Spot elevations at entrance to both ingress/egress will need to be shown on the grading plan as well. Provide a letter from the drainage engineer stating that the grading plan shows conformance to the Drainage Report. When ready to submit the grading plan, provide one copy of the record of survey, 3 copies of the grading plan, 4 copies of the SWPPP, and two copies of the drainage report. 13) DS Sec.2-03.7.4: Please include a response letter to the comments along with the revised copies of the Record of Survey. RESUBMITTAL REQUIRED: Submit the revised Record of Survey, boundary calculations, and response letter. If you have any questions, please call me at 791-5550 extension 2204. Elizabeth Eberbach, PE Civil Engineer Engineering Division Development Services |
| 08/30/2005 | DAVID RIVERA | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: David Rivera Principal Planner PROJECT: S05-125 24th and Park Avenue - Habitat for Humanity Record of Survey TRANSMITTAL: 08/30/05 DUE DATE: 08/18/05 COMMENTS: 1. Section 4.1.7.1, LUC, permits a maximum of one year from the date of application to obtain approval of a tentative plat. If, at the end of that time, the tentative plat has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this tentative plat is July 20, 2006. 2. Draw and label the Jurisdictional limits on the location map. The limits in question are along the West Side of the location map next to the rail road tracks. The limits are for the City of Tucson and South Tucson. Please add the requested information. DS 2-3.11.7.D.4 3. Please increase the text height of the words BOOK and PAGE along the right side of the paper. DS 2-03.11.7.E 4. The brief legal description in the title block should include that this is a resubdivision of lot 13 block B. Revise the title block as requested. DS 2-02.11.7.F.4 5. This project has been assigned the subdivision case number S05125. Please list the case number in the lower right corner of all plan sheets. DS 2-03.11.8.B.1 6. Add the following note. "Lots with frontage on a street designated a Major Street or Route shall have ingress-egress designed in a manner so that motor vehicles do not back out onto the Major Street or Route, through the use of circular drives, turnarounds, or other similar solutions." This note applies to lot 1. DS 2-03.11.8.B.6 7. Add the following Record of Survey paragraph. CERTIFICATE OF SURVEY "I hereby certify that the boundary survey as shown on this Record of Survey was performed under my direction and that all existing or proposed survey monuments and markers shown are correctly described. I further certify that this Record of Survey was prepared under my direction." DS 2-03.11.9.A 8. All required dedications of right-of-way must be executed prior to approval of the record of survey. The owner/applicant must contact the City of Tucson Real Estate Division for information and procedures for dedication of right of way. Please contact Jim Rossi at 791-4181 for information on the proper paperwork and recordation process. Add a note on the plan next to the right of way dedication note as follows. "Right of way dedication per Docket ______ and Page ______." DS 2-03.11.11.E 9. All proposed easements must be recorded prior to approval of the Record of Survey. All docket and pages must be listed on the plan. Record all proposed easements, list on the plan the docket and pages for each easement, and provide to CDRC with the next submittal package copies of the recorded documents. DS 2-03.11.12.A If applicable to this site all existing easements that are to be abandoned or vacated must be completed prior to approval of the record of survey. Copies of the recorded documents must be submitted along with the next submittal package. DS 2-03.11.11.A 10. A one-foot no-vehicular access easement must be provided along the west property boundary of lots 2 and 3. Add the one-foot no-vehicular access easement to the plan and list the docket and page number. DS 2-03.11.12.B 11. Add a note to the plan that a separate site plan must be submitted for review and approval for development of each lot. If you have any questions about this transmittal, please call David Rivera, (520) 791-5608. C:\planning\cdrc\recordofsurvey\S05125ros.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised record of survey plan and additional requested documents. |
| 08/31/2005 | CRAIG GROSS | OTHER AGENCIES | PIMA ASSN OF GOVTS | Passed | |
| 08/31/2005 | PATRICIA GEHLEN | ZONING-RECORDATION | REVIEW | Denied | see comments |
| 08/31/2005 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES August 31, 2005 Daniel White Physical Resources Engineering, Inc. P.O. Box 36985 Tucson, AZ 85740 Subject: S05-125 24th & Park Habitat for Humanity Record of Survey Dear Dan: Your submittal of July 21, 2005, for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLUELINES MUST BE FOLDED 5 Copies Revised Record of Survey (Addressing, Engineering, Zoning, Wastewater, DSD) Should you have any questions, please call me at 791-5608, ext 1179. Sincerely, Patricia Y. Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 326-1217 |