Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Plan Number - S05-114
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/16/2007 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 04/05/2007 | KAROL ARAGONEZ | ZONING | REVIEW | Approved | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Karol Aragonez Planner PROJECT: S05-114 Escalante-Houghton Tentative Plat Resubmittal TRANSMITTAL DATE: April 17, 2007 DUE DATE: April 17, 2007 COMMENTS: The Zoning Review Section verifies that the tentative plat meets the requirements of the Land Use Code. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the corrected tentative plat to verify that those changes do not affect any zoning requirements. If you have any questions about this transmittal, please call Karol Aragonez, (520) 791-5550, ext. 74960. KAA S:\zoning review\karol\planning\cdrc\tentativeplat\S05-114tpr1.doc |
| 04/12/2007 | LAITH ALSHAMI | ENGINEERING | REVIEW | Approved | Laith Alshami, Engineering and Floodplain Review, 04/17/2007, TO: Patricia Gehlen FROM: Laith Alshami, P.E. CDRC Engineering SUBJECT: Escalante-Houghton S05-114, T14S, R15E, SECTION 35 RECEIVED: Tentative Plat, Landscape Plan and Drainage Report on March 16, 2007 The subject project has been reviewed. The Drainage Report is acceptable for Tentative Plat purposes and it is hereby approved. Additional drainage information and a revised drainage report might be required with the Grading Plan. The Tentative Plat is recommended for approval pertaining to Engineering and Floodplain Review. Please be advised of the following: 1. Compliance with Rezoning Condition #3 is required prior to the issuance of the first building permit. Clarify, in the Grading Plan submittal, how this condition will be complied with. 2. Add a General Note, on the Grading Plan, which states that the unnamed wash, which is classified as "Xeroriparian Habitats" shall be preserved and fenced off for grading, even if no encroachment is proposed. The Grading Plan shall depict the grading limits and the fence that will separate the wash from the construction activities. 3. The slope treatment and setback lines shall be determined in the Geotechnical Report, which shall be submitted with the Grading Plan. 4. For safety reasons, ensure, on the Landscape Plan, that either plants are not proposed within the existing and future sight visibility triangles, or the plants must comply with the requirements of Development Standard 3-01.5.1.A.1. at all times. 5. Ensure, on the Landscape Plan that landscaping will not interfere with the proposed drainage structures. |
| 04/20/2007 | ROGER HOWLETT | COT NON-DSD | COMMUNITY PLANNING | Approved | DEPARTMENT OF URBAN PLANNING & DESIGN Regarding SUBJECT: Community Design Review Committee Application CASE NUMBER: CASE NAME: DATE SENT S05-114 Escalante-Houghton 04/19/07 ( ) Tentative Plat ( ) Development Plan () Landscape Plan () Revised Plan/Plat ( ) Board of Adjustment ( ) Other – NPPO Plan CROSS REFERENCE: C9-03-14 NEIGHBORHOOD PLAN: South Pantano Area Plan SCENIC/GATEWAY ROUTE: Houghton Road is Scenic Route COMMENTS DUE BY: 11/24/06 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: ( ) No Annexation or Rezoning Conditions, Not an RCP - No Comment ( ) Proposal Complies with Annexation or Rezoning Conditions ( ) RCP Proposal Complies With Plan Policies ( ) See Additional Comment Attached () No Additional Comments - Complies With Planning Comments Submitted on: 11/24/06 Resubmittal Required: ( ) Tentative Plat ( ) Development Plan ( ) Landscape Plan ( ) Other REVIEWER: drcorral DATE: 4/19/07 |
| 04/23/2007 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Approved | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES April 23, 2007 Michael John Baker Floerchinger-Sadler-Steele-Baker, inc. 326 S. Convent Tucson, Arizona 85701 Subject: S05-114 Escalante- Houghton Tentative Plat Dear Mike: The above referenced plan has been APPROVED by the Community Design Review Committee, subject to the revisions required on the mylars. Please submit the following documents for sign-off: 1 Reproducible Océ or Photo Mylar of the Plat, Landscape Plan and NPPO. Additional blackline copies will be made from the complete set and distributed to various review agencies for their files. These copies will be ordered from the City's contracted print company and billed to you unless you already have an account at another printing company. Please let us know which printing company you would prefer to use and list them on your attached transmittal form when submitting your mylars to the CDRC office for sign-off approval. Your printing company will deliver the mylar and three (3) blackline copies to your office. If you are out of town you will need to contact the printing company for pick up or mailing arrangement options. PLEASE NOTE THAT THIS FINAL PLAT MUST BE APPROVED BY MAYOR AND COUNCIL AND RECORDED PRIOR TO APRIL 22, 2007 PER LUC 4.1.7.3 (TENTATIVE PLAT WAS APPROVED ON APRIL 23, 2007). TO ENSURE A MORE RAPID REVIEW OF THE MYLARS, PLEASE HAVE THE CITY OF TUCSON APPROVAL STAMP PLACED ON EACH SHEET OF THE SUBMITTAL SET, PREFERABLY IN THE LOWER RIGHT HAND CORNER NEAR THE TITLE BLOCK. THE STAMP IS LOCATED AT http://www.ci.tucson.az.us/dsd/CDRC Rezoning/CDRC/CDRC Stamp/cdrc stamp.html. Should you have any questions, please call me at 791-5608 extension 1179. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 628-1375 |