Plan Number: S05-109
Parcel: Unknown

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW

Plan Number - S05-109
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/13/2006 JOE LINVILLE LANDSCAPE REVIEW Denied 1) The screening proposed along Fairview Avenue in front of Lot 1 is required to be located behind or at the back of the street landscape border per LUC 3.7.3.2.C.

2) Revise the plans to show any applicable sight visibility triangles and revise the landscape plans to comply with the sight visibility standards. There are sight visisbility triangles along Fairview Industrial Park Place also.
DS 3-01.5.0

3) The parking design on lots 5 & 6 does not provide one tree within forty feet of every parking space as required.
LUC 3.7.2.3.A.1.a

RESUBMITTAL OF ALL PLANS IS REQUIRED
01/17/2006 JOSE ORTIZ ENGINEERING REVIEW Approved Approved 1-17-2006

If you have any questions you may contact me at 791-5640 ext.1191 or Jose.Ortiz@tucsonaz.gov
01/28/2006 CRAIG GROSS ZONING REVIEW Approved Twenty-five foot encroachment allowed per Walter Tellez.
01/30/2006 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

January 30, 2006

Morris I. Riback
Urban Engineering
877 South Alvernon Way, Suite 200
Tucson, AZ 85711

Subject: S05-109 Fairview Industrial Park Tentative Plat

Dear Morris:

Your submittal of December 30, 2005 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLUELINES MUST BE FOLDED

3 Copies Revised Tentative Plat (Landscape, Zoning, DSD)

3 Copies Revised Landscape Plan (Landscape, Zoning, DSD)



Should you have any questions, please call me at 791-5608, ext 1179.

Sincerely,

Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 318-3808
12/30/2005 MARILYN KALTHOFF START PLANS SUBMITTED Completed