Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Plan Number: S05-103
Parcel: Unknown

Address:
3229 E 3RD ST

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW

Plan Number - S05-103
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/02/2005 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
11/14/2005 KAY MARKS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: THIRD STREET RCP / REVISED TENTATIVE PLAT
DATE: November 14, 2005



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.



***The Pima County Addressing Section can use digital CAD drawing files when
submitted with your final plat Mylar. These CAD files can be submitted through the Pima
County Subdivision Coordinator. The digital CAD drawing files expedite the addressing
and permitting processes when we are able to insert this digital data into the County's
Geographic Information System. Your support is greatly appreciated.***
11/15/2005 JOSE ORTIZ ENGINEERING REVIEW Approved A permit or a private improvement agreement may be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information. This comment can be addressed during the grading plan review period.

If you have any questions, please feel free to contact me at 791-5550 x1191 or Jose.Ortiz@tucsonaz.gov
11/18/2005 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Approved DEPARTMENT OF URBAN PLANNING & DESIGN

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

S05-103 Third Street RCP 11/17/05

(XXXX) Tentative Plat
() Development Plan
(XXXX) Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
(XXXX) Other – Elevations, Floor Plans

CROSS REFERENCE:

NEIGHBORHOOD PLAN: Alvernon Broadway Area Plan

GATEWAY/SCENIC ROUTE:

COMMENTS DUE BY: November 17, 2005

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

() No Annexation or Rezoning Conditions, Not an RCP - No Comment
() Proposal Complies with Annexation or Rezoning Conditions
() RCP Proposal Complies With Plan Policies
() See Additional Comments Attached
(XXXX) No Additional Comments - Complies With Planning Comments Submitted on: 7/28/05
() Resubmittal Required:
() Tentative Plat
() Development Plan
() Landscape Plan
() Other

REVIEWER: DCE 791-4505 DATE: November 8, 2005 DEPARTMENT OF URBAN PLANNING & DESIGN
11/23/2005 DALE KELCH COT NON-DSD TRAFFIC Approved Traffic Engineering recommends APPROVAL of this TP.

D. Dale Kelch, PE
Senior Engineering Associate
Traffic Engineering Division
(520)791-4259x305
(520)791-5526 (fax)
dale.kelch@tucsonaz.gov
12/01/2005 TERRY STEVENS ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Terry Stevens
Lead Planner

PROJECT: S05-103 Resubmittal
Third Street RCP
Tentative Plat

TRANSMITTAL: 12/01/05

DUE DATE: 11-17-05

COMMENTS:

1. The second half of the following comment has not been addressed. As LUC Sec. 3.6.1.4.A.9 Provide a note stating: "All mechanical equipment shall be screened from adjacent streets exterior to the project and from adjacent existing residential development. Screening shall be architecturally integrated with the overall design of the RCP". Clearly indicate if equipment is to be ground mounted or roof mounted. If the equipment is to be roof mounted provide a detail showing how it will comply with the architectural design of the overall project. If a detail is required, provide it on the tentative plat.

2. As per LUC Sec. 3.6.1.4.D.1 In the key notes #3 it has been indicated using the developing area setback requirements. Since no new streets are being provided established area setbacks are required. It appears that the structures will meet the requirements of established area setbacks as per LUC Sec. 3.2.6.5.A. Change the note to indicate the required front street perimeter setback of 20' or 11/2 the height of the proposed walls from the front property line.

3. As per DS 2-10.3.2.F Two (2) copies of protective covenants or common use agreements are required if shared areas are to be established by easements over individually-owned property.

4. The above comments are minor in nature and can be reviewed over the counter, once the correction have been made, by setting an appointment with me at any time that is convenient for you.


If you have any questions about this transmittal, please call Terry Stevens, (520) 791-5550 ext. 2000.


TLS C:\planning\cdrc\tentativeplat\S05-103tp.doc
12/23/2005 FRODRIG2 PIMA COUNTY WASTEWATER Approved December 22, 2005

To: Steven Gregor, Gregor & Grenier Engineering

Thru: Patricia Gehlen, CDRC Project Manager
City of Tucson Development Services Department

____________________________________
From: Tim Rowe, P.E. (520-740-6563), representing the Pima County
Departments of Wastewater Management and Environmental Quality

Subject: Third Street RCP, Lots 1-3
Tentative or Preliminary Plat - 2nd Submittal
S05-103

The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.



Sheet 1: Show the correct plan number (I-530) for the existing public sewer line in East 3rd Street.

Please be aware that this project that will not qualify for any sewer connection fee discounts for being located within the boundaries of an old sewer improvement district after Pima County Ordinance 2005-112 goes into effect on January 6, 2006, but your client may be able to obtain some demolition credits to reduce the cost of connecting these new structures to the public sewer system.

Arial photos taken in 2002 show an existing structure on this property that the new lot layout will not accommodate. Please contact Ms. Yvonne Suarez of the Pima County Wastewater Management Department at 740-6500 regarding the procedure for obtaining demolition credits for the wastewater fixture units in this structure.

Subject to the above, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the tentative or preliminary plat. The required revision(s) may be shown on the Mylars.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.


If you have any questions regarding the above mentioned comments, please contact me at the telephone number shown under my signature on the first page of this letter

CC: Project FileDecember 20, 2005

To: Steven Gregor, Gregor & Grenier Engineering

Thru: Patricia Gehlen, CDRC Project Manager
City of Tucson Development Services Department

____________________________________
From: Michael Harrington (520-740-6579), representing the Pima County
Departments of Wastewater Management and Environmental Quality

Subject: Third Street RCP, Lots 1-3
Final Plat - 1st Submittal
S05-103

The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.



Sheet

Sheet


If you have any questions regarding the above mentioned comments, please contact me at the telephone number shown under my signature on the first page of this letter

CC: Project File
12/23/2005 FRODRIG2 PIMA COUNTY WASTEWATER Approved January 6, 2006

TO: Steven Gregor, P.E.
Gregor & Grenier Engineering, Inc.

THRU: Patricia Gehlen
City of Tucson, Development Services Department

FROM: Dickie Fernández, E.I.T.
Pima County Development Services Department
Development Review Division (Wastewater)

SUBJECT: Third Street RCP, Lots 1-3
Tentative Plat – 2nd Submittal
S05-088


The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


This project is hereby approved as submitted

If you have any questions regarding the above mentioned comments, please contact me. Sincerely,





Dickie Fernández, E.I.T.
Telephone: (520) 740-6947

Copy: Project
12/28/2005 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

December 28, 2005

Steven Gregor
Gregor & Grenier Engineering, Inc.
5232 East Pima Street, Suite A
Tucson, AZ 85712

Subject: S05-103 Third Street RCP Tentative Plat

Dear Steve:

The above referenced plan has been CONDITIONALLY APPROVED by the Community Design Review Committee, subject to the revisions required on the mylars. Please submit the following documents for sign-off.

1 Reproducible Oce or Photo Mylar copy of the Plat, landscape plan and NPPO.

Should you have any questions, please call me at 791-5608, ext 1179.


Sincerely,


Patricia Y. Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 319-1181