Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Plan Number - S05-096
Review Name: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/14/2005 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 09/23/2005 | KAY MARKS | PIMA COUNTY | ADDRESSING | Approved | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 KAY MARKS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: KAY MARKS, ADDRESSING OFFICIAL SUBJECT: S05-096 SONTERRA AT WILLIAMS CENTRE/REVISED FINAL PLAT DATE: September 20, 2005 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project. ***The Pima County Addressing Section can use digital CAD drawing files when submitted with your final plat Mylar. These CAD files can be submitted through the Pima County Subdivision Coordinator. The digital CAD drawing files expedite the addressing and permitting processes when we are able to insert this digital data into the County’s Geographic Information System. Your support is greatly appreciated.*** jg |
| 09/28/2005 | JOSE ORTIZ | ENGINEERING | REVIEW | Denied | DATE: SEPTEMBER 28, 2005 TO: Patricia Gehlen, CDRC Manager FROM: Jose E. Ortiz Engineering Division SUBJECT: Sonterra At Williams Centre Final Condominium Conversion Plat S05-096 (Second Review)T14S, R14E, SECTION 14 RESUBMITTAL REQUIRED: Final Plat Engineering has reviewed the received items and does not recommend approval of the Final Plat. Referring to the Development Plan submitted as a reference document, it became apparent that there are existing detention basins that are not being accounted for in the final plat. 1. Show detention/retention areas in a surveyable and readily retraceable manner. Development Standards 2-03.6.4.I 2. Common areas with different uses and maintenance requirements must be given separate designations; therefore separate the drainage/detention basins from other common areas and give it its own designation (i.e. Common Element "A" (Vehicular Use), Common Element "B"(Landscape), Common Element "C" (Drainage), etc. These designations must be shown on the plan in the proper locations. DS 2-03.6.4.C CC&R Comments 1. Need a typical drainage facility maintenance note per Sections 1.5.1 and 1.5.2 of the Standard Manual for Drainage Design and Floodplain Management for the existing detention basins. If you have any questions or need clarification on any of these comments please feel free to contact me at 791-5550 x1191 or Jose.Ortiz@ci.tucsonaz.govs Jose E. Ortiz Civil Engineer City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 791-5550 x1191 office (520) 879-8010 fax |
| 10/10/2005 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES October 10, 2005 Wendell Harness Stantec Consulting 201 North Bonita Avenue, Suite 101 Tucson, AZ 85745 Subject: S05-096 Sonterra at Williams Centre Final Plat Dear Wendell: Your submittal of September 14, 2005 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLUELINES MUST BE FOLDED 2 Copies Revised Final Plat (Engineering, DSD) 2 Copies Revised CC&R's (Engineering, DSD Should you have any questions, please call me at 791-5608 ext. 1179. Sincerely, Patricia Y. Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 750-7470 |