Plan Review Detail
Review Status: Completed
Review Details: FINAL PLAT REVIEW
Plan Number - S05-096
Review Name: FINAL PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/21/2005 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 07/14/2005 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Approved | SUBJECT: SONTERRA AT WILLIAMS CENTRE S05-096 Tucson Electric Power Company has reviewed and approved the final plat submitted for review June 21, 2005. Liza Castillo Right of Way Agent Land Management Tucson Electric Power Co. (520) 917-8745 lcastillo@tep.com <mailto:lcastillo@tep.com> |
| 07/20/2005 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Approved | Office of the Pima County Assessor 115 N. Church Ave. Tucson, Arizona 85701 BILL STAPLES ASSESSOR TO: CDRC Office Subdivision Review City of Tucson (FAX# 791-5559) FROM: Ed Abrigo, Mapping Supervisor Pima County Assessor’s Office Mapping Department DATE: July 20, 2005 RE: Assessor’s Review and Comments Regarding Final Plat S05-096 Sonterra at Williams Centre T141414 (128-10) * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * X Plat meets Assessor’s Office requirements. _______ Plat does not meet Assessor’s Office requirements. COMMENTS: Thank you for your submittal. Please add the north arrow to sheet 3 before recording this plat. NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED. Susan King |
| 07/20/2005 | JOSE ORTIZ | ENGINEERING | REVIEW | Denied | DATE: JULY 6, 2005 TO: Patricia Gehlen, CDRC Manager FROM: Jose E. Ortiz Engineering Division SUBJECT:Sonterra At Williams Centre Final Condominium Conversion Plat S05-096 (First Review) T14S, R14E, SECTION 14 RESUBMITTAL REQUIRED: Final Plat Engineering has reviewed the received items and does not recommend approval of the Final Plat. 1. Title block should read 'Final Plat - A Condominium Conversion Project' 2. Please Identify location of limited common easement. 3. The addresses on the sheet titled "ADDRESSING TABLE FOR APARTMENT BUILDING UNITS" on the approved 1994 Development Plan for Sonterra Apartments sheet 3 of 6 does not match proposed addresses for this Condominium Conversion Project. Please verify that the proposed addresses are correct. 4. On the project layout map the basis of bearing shows this portion of the project being in section 11 and section 12. Should this be section 14 and section 13? 5. To avoid confusion please consider providing a bearing and distance to one corner of each building from a found survey monument versus a bearing and distance from one corner of a building to another corner of a building. If you have any questions or need clarification on any of these comments please feel free to contact me at 791-5550 x1191 or Jose.Ortiz@ci.tucsonaz.govs Jose E. Ortiz Civil Engineer City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 791-5550 x1191 office (520) 879-8010 fax |
| 07/25/2005 | DAN CASTRO | ZONING | REVIEW | Approv-Cond | COMMENTS: The Zoning Review Section approves the final plat for this subdivision, subject to the following changes on the executed final plat. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised final plat to verify that those changes do not affect any zoning requirements. 1. This plat has been assigned subdivision case number S05-096. Note the subdivision case number in the lower right corner of each sheet. (D.S. 2-03.6.1.K) 2. Since the project is located within the boundaries of the Williams Addition Planned Area Development (PAD), include a reduced-scale map of the entire PAD District on the first sheet, indicating the location of the portion being developed. (D.S. 2-03.6.1.F) |
| 07/25/2005 | FRODRIG2 | COT NON-DSD | REAL ESTATE | Approved | No objection |
| 07/29/2005 | FRODRIG2 | PIMA COUNTY | WASTEWATER | Approv-Cond | July 26, 2005 To: Wendell Harness, Stantec Consulting Thru: Patricia Gehlen, CDRC Project Manager City of Tucson Development Services Department ____________________________________ From: Tim Rowe, P.E. (520-740-6563), representing the Pima County Departments of Wastewater Management and Environmental Quality Subject: Sonterra at Williams Centre Final Plat - 1st Submittal S05-096 The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. Sheet 1: The Dedication language doesn't adequately grant the common elements to the City of Tucson, Pima County and all utility companies as easements. Revise the 3rd paragraph of the Dedication to read as follows: COMMON ELEMENTS AND PRIVATE EASEMENTS AS SHOWN HEREON, ARE RESERVED FOR THE PRIVATE USE AND CONVENIENCE OF ALL OWNERS WITHIN THIS SUBDIVISION, AND ARE GRANTED AS EASEMENTS TO THE CITY OF TUCSON, PIMA COUNTY, AND ALL UTILITY COMPANIES, PUBLIC AND PRIVATE, FOR THE INSTALLATION, ACCESS AND MAINTENANCE OF PUBLIC SEWERS, UTILITIES AND ANY OTHER USES AS DESIGNATED BY THIS PLAT. Note: I didn’t find any private easements on the plat. If there aren't any, the phrase AND PRIVATE EASEMENTS should be deleted from the suggested language above. Subject to the above, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the final plat. The required revision(s) may be shown on the Mylars. Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality. Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution. If you have any questions regarding the above mentioned comments, please contact me at the telephone number shown under my signature on the first page of this letter |
| 08/05/2005 | KAY MARKS | PIMA COUNTY | ADDRESSING | Denied | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 KAY MARKS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: KAY MARKS, ADDRESSING OFFICIAL SUBJECT: S05-096 SONTERRA AT WILLIAMS CENTRE / FINAL PLAT DATE: AUGUST 5, 2005 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval: 1: Correct Unit Numbers in Building 5. 2: Correct Unit Numbers in Building 15 (the duplicate numbers should be 15206, 15306, 15108, 15208, 15308). 3: Unit Numbers for building 16 in Title Block should be 16101-16108, 16201-16208, 16301-16308. |
| 08/08/2005 | CRAIG GROSS | ZONING-DECISION LETTER | REVIEW | Completed |