| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/20/2006 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 10/31/2006 | FRODRIG2 | COT NON-DSD | REAL ESTATE | Denied | S05-094 Aldea Del Norte: Resubmittal - CDRC - Final Plat Review - Per 1/26/06 meeting w/ TETRA Tech, a drainage easement is required for at least the E. 25' of the 28' proposed to be dedicated by "paper plat process." Final plat does not reflect this change. It is understood a revised drainage report is forthcoming. |
| 11/08/2006 | KAROL ARAGONEZ | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Karol Aragonez Planner PROJECT: S05-094 Aldea Del Norte Final Plat TRANSMITTAL DATE: November 7, 2006 DUE DATE: November 20, 2006 COMMENTS: The Zoning Review Section approves the final plat for this subdivision, subject to the following changes on the executed final plat. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised final plat to verify that those changes do not affect any zoning requirements. 1. The tentative plat must be approved prior to approval of the final plat. Any changes made to the tentative plat that affects the final plat will void this approval. If you have any questions about this transmittal, please call Karol Aragonez, (520) 791-5550, ext. 1197. KAA S:\zoning review\karol\planning\cdrc\finalplat\S05-094fpr.doc |
| 11/20/2006 | KAY MARKS | PIMA COUNTY | ADDRESSING | Denied | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 KAY MARKS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: KAY MARKS, ADDRESSING OFFICIAL SUBJECT: S05-094 ALDEA DEL NORTE/REVISED FINAL PLAT DATE: 11/16/06 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval: Correct the legal description on all Title Blocks. es |
| 12/04/2006 | JOSE ORTIZ | ENGINEERING | REVIEW | Denied | DATE: December 4, 2006 TO: Patricia Gehlen, CDRC Manager FROM: Jose E. Ortiz, Civil Engineering SUBJECT: Engineering review of Aldea Del Norte Final Plat. The activity number is S05-094. RESUBMITTAL REQUIRED: Final Plat Engineering has reviewed the received items and does not recommend approval of the Final Plat. 1. Include a response letter with the next submittal that states how all comments have been addressed. 2. It appears that the following comments were not addressed from the previous Engineering review. Please look over and contact me with any questions/concerns. 3. Show the detention/retention areas in a surveyable and readily retraceable manner. DS 2-03.6.4.I 4. At least one (1) corner of the subdivision will be tied by course and distance to a section corner, a quarter section corner, or an established City or County survey monument. The plat must include a description of that corner marker and an indication of how the bearings were determined. Corner tie recordation information is to be provided on the plat. DS 2-03.6.5.A. Label the northern BCSM on Country Club along the Basis of Bearing being used for this project. 5. The Covenants, Conditions, and Restrictions (CC&Rs) shall have a note stating (a) that the owner or owners shall be solely responsible for operation, maintenance, and liability for drainage structures and detention basins; (b) that the owner or owners shall have an Arizona Registered Professional Civil Engineer prepare a certified inspection report for the drainage and detention/retention facilities at least once each year, and that these regular inspection reports will be on file with the owner for review by City staff, upon written request; (c) that City staff may periodically inspect the drainage and detention/retention facilities to verify that scheduled and unscheduled maintenance activities are being performed adequately; and (d) that the owner or owners agree to reimburse the City for any and all costs associated with maintaining the drainage and detention/retention facilities, should the City find the owner or owners deficient in their obligation to adequately operate and maintain their facilities. SMDDFM 14.3.4.2 6. A detention/retention basin check list should be provided within the CC&R's 7. Provide an Assurance Package for review and to cross check against the Final Plat. The Final Plat cannot receive Engineering approval until the Assurances have been crossed checked against the Final Plat. If you have any questions, I can be reached at 791-4259 ext. 305 or jose.ortiz@tucsonaz.gov Jose E. Ortiz, PE Civil Engineer |
| 12/05/2006 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES December 5, 2006 Tim McCann Tetra Tech, Inc. 33 North Stone Ave. Tucson, Arizona 85701-1413 Subject: Aldea Del Norte Final Plat Dear Tim: Your submittal of October 20, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLACKLINES MUST BE FOLDED 4 Copies Revised Final Plat (Addressing, Engineering, Real Estate, DSD) Should you have any questions, please call me at 791-5608 extension 1179. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 844-5278 fpresubmittal |