Plan Number: S05-094
Parcel: Unknown

Review Status: Completed

Review Details: FINAL PLAT REVIEW

Plan Number - S05-094
Review Name: FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/29/2006 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
09/08/2006 FRODRIG2 PIMA COUNTY WASTEWATER Approv-Cond September 8, 2006

To: Tim McCann, Tetra Tech , Inc.

Thru: Patricia Gehlen, CDRC Project Manager
City of Tucson Development Services Department

____________________________________
From: Michael J.Harrington (520-740-6579), representing the Pima County
Departments of Wastewater Management and Environmental Quality

Subject: Aldea Del Norte
Lots 1 Through 12
Final Plat - 1st Submittal
S05-094

The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


Sheet 1: In the DEDICATION block, 4th paragraph. Although the City Of Tucson may accept that common areas are granted as easements to the PUBLIC, Pima County prefers that these elements be:

GRANTED AS EASEMENTS TO THE CITY OF TUCSON, PIMA COUNTY AND ALL UTILITY COMPANIES…

Sheet 1: Add a General Note that states:

THE LANDSCAPING WITHIN ALL PUBLIC SEWER EASEMENTS SHOWN HEREON SHALL BE IN ACCORDANCE WITH THE PLANTING GUIDELINES OF PC/COT STANDARD DETAIL WWM A-4.

Sheet 1: Add a Permitting Note that states:

NO PERMITS FOR PERMANENT STRUCTURES (I.E., MASONRY WALLS, FENCES, ETC.) ON OR THROUGH THE PUBLIC SEWER EASEMENT WILL BE ISSUED WITHOUT SEPARATE WRITTEN CONSENT OF PIMA COUNTY WASTEWATER MANAGEMENT DEPARTMENT.

Sheet 2: Revise the label at the 20’ SEWER ESMT, IN Common Area “B”, so that it states:

20’ PUBLIC SEWER ESMT, BY THIS PLAT
Subject to the above, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the final plat. The required revision(s) may be shown on the Mylars.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.


If you have any questions regarding the above mentioned comments, please contact me at the telephone number shown under my signature on the first page of this letter

CC: Project File
09/11/2006 KAROL ARAGONEZ ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Karol Aragonez
Planner

PROJECT: S05-094
Aldea Del Norte
Final Plat

TRANSMITTAL DATE: September 11, 2006

DUE DATE: September 27, 2006

COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. An applicant has one (1) year from the date of approval of tentative plat to obtain approval of a final plat that complies with zoning and other development requirements in effect at the time of application. This final plat must be approved and recorded on or before May 12, 2007.

2. Within the location map please center the subject property within the square mile.
DS 2-03.6.1.D.1

3. Please add Common Area "C" and it's purpose in the title block. Please verify that Common Area "B" is open space or if it should be labeled as detention/retention basin.
DS 2-03.6.1.H.1

4. Please add note to the final plat stating "The total number of lots is ____".
DS 2-03.6.2.B

5. Please add note stating "There will be no further division of lots without the expressed approval of the City of Tucson".
DS 2-03.6.2.H

6. Please revise the Certification of Survey to read verbatim to DS 2-03.6.3.A
DS 2-036.3.A

7. Please revise the second paragraph of the dedication to read - for the purposes of access "for" installations.
DS 2-03.6.3.B.2.b

8. Please make sure that once the CC&Rs are recorded that the docket and page number of the dedication 3rd paragraph is filled in with said numbers.

9. Please add to the dedication paragraph the hold harmless statement verbatim as provided in DS 2-03.6.3.B.3.
DS 2-03.6.3.B.3

10. Please correct the assurance signature line replacing Planning Director with "Development Services Department Director".
DS 2-03.6.3.E

11. Please indicate the street name for common area "A" and label as private.
DS 2-03.6.4.A

12. On the plat please identify the land area within the traffic circle (Common Area "A", "B", or "C") and include the square footage.
DS 2-03.6.4.C

13. Please provide clear language within the CC&Rs that provides for maintenance of all common areas/landscaping within the subdivision.
DS 2-03.6.6.A

If you have any questions about this transmittal, please call Karol Aragonez, (520) 791-5550.


KAA S:\zoning review\karol\planning\cdrc\finalplat\S05-094fp.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat, CC&R's and additional requested documents.
09/14/2006 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Approved SUBJECT: ALDEA DEL NORTE

Lots 1-12

S05-094



The Final Plat for the subject project will meet this Company's easement
requirements.

Please forward any resubmittals of the final plat to this office.



Electric service will be provided to this subdivision in accordance with
the rules and regulations approved by the Arizona Corporation
Commission.



Please contact me at (520) 917-8745 if you have any questions.


Liza Castillo
Right of Way Agent
Land Management
Tucson Electric Power Co.
(520) 917-8745
lcastillo@tep.com
09/27/2006 KAY MARKS PIMA COUNTY ADDRESSING Denied 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S05-094 ALDEAD DEL NORTE/FINAL PLAT
DATE: 9/27/06



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:

1.) Label Placita Aldea Linda on sheet 2.





es
09/28/2006 ED ABRIGO PIMA COUNTY ASSESSOR Approved Office of the Pima County Assessor


115 N. Church Ave.


Tucson, Arizona 85701



BILL STAPLES

ASSESSOR










TO: CDRC Office

Subdivision Review

City of Tucson (FAX# 791-5559)



FROM: Gary Ault, Mapping Supervisor

Pima County Assessor's Office

Mapping Department



DATE: September 26, 2006





RE: Assessor's Review and Comments Regarding Final Plat

S05-094 ALLDEA DEL NORTE T131429





* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *



X Plat meets Assessor's Office requirements.

_______ Plat does not meet Assessor's Office requirements.





COMMENTS:



THANK YOU FOR YOUR SUBMITTAL.



NOTE: THE ASSESSOR'S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS
TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN
THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING
THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK
YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.







ROSANNA WERNER
09/29/2006 PGEHLEN1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Passed
10/11/2006 JOSE ORTIZ ENGINEERING REVIEW Denied DATE: October 11, 2006

TO: Patricia Gehlen, CDRC Manager

FROM: Jose E. Ortiz, Civil Engineering

SUBJECT: Engineering review of Aldea Del Norte Final Plat. The activity number is S05-094.

RESUBMITTAL REQUIRED: Final Plat

Engineering has reviewed the received items and does not recommend approval of the Final Plat.


1. Include a response letter with the next submittal that states how all comments have been addressed.

2. "The total number of lots is ____." DS 2-03.6.2.B

3. Add the following note on all plats. The purpose of this note is solely for review for compliance with local and state laws governing subdivision and lot splits. "There will be no further division of lots without the expressed approval of the City of Tucson." DS 2-03.6.2.H

4. If the subdivision was the result of a rezoning case and did not require submittal and review of a tentative plat, add the following note: "Any relocation, modification, etc., of existing utilities and/or public improvements necessitated by the proposed development will be at no expense to the public." DS 2-03.6.2.I

5. Show the detention/retention areas in a surveyable and readily retraceable manner. DS 2-03.6.4.I

6. At least one (1) corner of the subdivision will be tied by course and distance to a section corner, a quarter section corner, or an established City or County survey monument. The plat must include a description of that corner marker and an indication of how the bearings were determined. Corner tie recordation information is to be provided on the plat. DS 2-03.6.5.A. Label the northern BCSM on Country Club along the Basis of Bearing being used for this project.

7. The Covenants, Conditions, and Restrictions (CC&Rs) shall have a note stating (a) that the owner or owners shall be solely responsible for operation, maintenance, and liability for drainage structures and detention basins; (b) that the owner or owners shall have an Arizona Registered Professional Civil Engineer prepare a certified inspection report for the drainage and detention/retention facilities at least once each year, and that these regular inspection reports will be on file with the owner for review by City staff, upon written request; (c) that City staff may periodically inspect the drainage and detention/retention facilities to verify that scheduled and unscheduled maintenance activities are being performed adequately; and (d) that the owner or owners agree to reimburse the City for any and all costs associated with maintaining the drainage and detention/retention facilities, should the City find the owner or owners deficient in their obligation to adequately operate and maintain their facilities. SMDDFM 14.3.4.2

8. A detention/retention basin check list should be provided within the CC&R's

9. Provide an Assurance Package for review and to cross check against the Final Plat.

10. The traffic circle needs to be re-evaluated and must provide proper maneuverability for fire and solid waste vehicles.
10/13/2006 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

October 13, 2006

Tim McCann
Tetra Tech, Inc.
33 North Stone Ave.
Tucson, Arizona 85701-1413

Subject: Aldea Del Norte Final Plat

Dear Tim:

Your submittal of August 29, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

5 Copies Revised Final Plat (Zoning, Addressing, Engineering, Real Estate, DSD)

3 Copies CC&R's (Zoning, Engineering, DSD)






Should you have any questions, please call me at 791-5608 extension 1179.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 844-5278
fpresubmittal
10/13/2006 FRODRIG2 COT NON-DSD REAL ESTATE Denied S05-094 Aldea del Norte: Final Plat Review - Concerning the dedication of the 28' of R/W by "paper plat process", Engineering Div./Floodplain has identified a conflict with dedicating this area and an apparent restriction of drainage along Country Club Rd. A meeting between TETRA Tech, Inc., and Floodplain Division is proposed to discuss the situation. Until resolved, Real Estate objects to finalize this plat until the drainage issue is resolved.