Plan Number: S05-094
Parcel: Unknown

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW

Plan Number - S05-094
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/06/2006 MARILYN KALTHOFF START PLANS SUBMITTED Completed
04/11/2006 FRODRIG2 PIMA COUNTY WASTEWATER Approv-Cond April 10, 2006

To: Dave Martin, Tetra Tech

Thru: Patricia Gehlen, CDRC Project Manager
City of Tucson Development Services Department

____________________________________
From: Michael Harrington (520-740-6579), representing the Pima County
Departments of Wastewater Management and Environmental Quality

Subject: Aldea Del Norte
Lots 1-12 and Common Areas "A" - "C"
Revised Tentative Plat - 1st Submittal
S05-094

The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.



Sheet 1: Revise the Legend block so that it shows:

The proposed and existing sewer lines and manholes that are used in the site plan on sheet 2.

Sheet 1: Revise the Owner/Developer block so that:

The word PLACE is spelled correctly in the 2nd line address.

Subject to the above, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the revised tentative plat. The required revision(s) may be shown on the Mylars.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.


If you have any questions regarding the above mentioned comments, please contact me at the telephone number shown under my signature on the first page of this letter

CC: Project File
04/18/2006 JOSE ORTIZ ENGINEERING REVIEW Approv-Cond The curb access ramp shown at Aldea Linda and the driveway to lots 2 & 5 needs to be modified. Consider using a ramp similar to the detail illustrated in the PC/COT DTL 207 sheet 1 of 3.

Grading Plan. If the grading plan has not yet been submitted it may be submitted at this time. The grading plan cannot be approved unless it is in conformance with an approved tentative plat.


If you have any questions, I can be reached at 791-5550 x1191 or Jose.Ortiz@tucsonaz.gov
04/21/2006 GLYNDA ROTHWELL UTILITIES TUCSON ELECTRIC POWER Approved SUBJECT: ALDEA DEL NORTE

Lots 1-12

S05-094



Tucson Electric Power Company (TEP) has no objection to the tentative
plat submitted for review April 7, 2006.



TEP will provide a preliminary electrical design on the Approved
Tentative Plat within fifteen (15) working days upon receipt of the
plat. Additional plans necessary for preparation of the design are:
building plans including water, electrical, landscape, sidewalk and
paving plans. Also, submit the AutoCAD version of the plat on a CD or
email to lcastillo@tep.com <mailto:lcastillo@tep.com> . Should you have
any questions, please contact me at (520) 917-8745.


Liza Castillo
Right of Way Agent
Land Management
Tucson Electric Power Co.
(520) 917-8745
lcastillo@tep.com
05/13/2006 PATRICIA GEHLEN ZONING REVIEW Approv-Cond Zoning
5/13/2006
On sheet 2 of 3, Lot 1-5 townhome detail and sheet 3 of 3 typical lot setbacks detail - please add a note that all lots will have at least 300 square feet of outdoor space per LUC 3.6.1.4.D.2.c. Verification of the 300 square feet will be required at time of SFR permitting.
05/13/2006 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

May 13, 2006

Dave Martin, P.E.
Tetra Tech, Inc.
33 North Stone Avenue, Suite 1500
Tucson, AZ 85701-1413

Subject: S05-094 Aldea Del Norte Tentative Plat

Dear Dave:

The above referenced plan has been CONDITIONALLY APPROVED by the Community Design Review Committee, subject to the revisions required on the mylars. Please submit the following documents for sign-off.

1 Reproducible Oce or Photo Mylar copy of the Plat, landscape plan and NPPO.

Should you have any questions, please call me at 791-5608, ext 1179.


Sincerely,


Patricia Y. Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 884-5278